1 / 1
thumbnail

Opis

Końcówka Serii
This XPSVNE safety module is for zero-speed detection. It meets the requirements of PL c/Category 2 conforming to EN/ISO 13849-1.and SILCL1 conforming to EN/IEC 61508 and EN/IEC 62061. Used in conjunction with XU2S single-beam photo-electric sensors (periodically tested), it establishes a category 2 light curtain conforming to IEC/EN 61496 parts 1 and 2. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.
Country of Origin
ID
Part Number
XPSVNE1142P
Tariff Code
85364190
EAN
3389119004213
UNSPSC
32151802
Metody płatności:
Najlepsza oferta od:
SKZaufany dostawca Automa.Net
Dostępność:
10 szt.
W magazynie
Zaktualizowano: 08-11-2024
Gwarancja:
12 miesięcy
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Łącznie 56 części w magazynie od 9 dostawców
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Dostępne Oferty (11)

XPSVNE1142P product image
Schneider Electric

XPSVNE1142P

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
ITZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
XPSVNE1142P product image
Schneider Electric

XPSVNE1142P

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
13 szt.
W magazynie
Zaktualizowano: 09-11-2024
Oferta od:
ITZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
XPSVNE1142P product image
Schneider Electric

XPSVNE1142P

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 21-10-2024
Oferta od:
GBZaufany dostawca Automa.Net
Szacowany czas dostawy:
15-20 listopada do Wielka Brytania
1
Wysyłka od:
£99.00
XPSVNE1142P product image
Schneider Electric

XPSVNE1142P

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
DEZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
XPSVNE1142P product image
Schneider Electric

XPSVNE1142P

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
11 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
GBZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€307.58

Specifications

Product Certifications
CSA || UL || TÜV
[Us] Rated Supply Voltage
24 V DC - 15...10 %
Range Of Product
Preventa Safety automation
Product Or Component Type
Preventa safety module
Safety Module Name
XPSVNE
Number Of Additional Circuits
2 solid state outputs
Output Type
relay, 1 NO + 1 NC, volt-free
Safety Module Application
for zero speed detection
Safety Reliability Data
MTTFd = 124.1 years EN/ISO 13849-1 || DC > 99 % EN/ISO 13849-1 || PFHd = 9.26E-9 1/h EN/IEC 62061
Function Of Module
monitoring 3-phase motor with star-delta starting || monitoring 3-phase motor with variable number of poles and star-delta starting || monitoring 3-phase motor + variable speed drive || monitoring 3-phase motor || monitoring XPS AK || monitoring star-delta motor starter and guard switch type XCS E || monitoring dc motor
Safety Level
can reach PL d/category 3 EN/ISO 13849-1 || can reach SILCL 2 EN/IEC 62061

Contractual warranty

Warranty
18 months

Complementary

Product Destination
for motor power supply <= 60 Hz
Height
99 mm
[Ith] Conventional Free Air Thermal Current
2.5 A relay output
Mounting Support
35 mm symmetrical DIN rail
Power Consumption In W
3.5 W
Minimum Output Voltage
17 V relay output
Minimum Output Current
10 mA relay output
Associated Fuse Rating
4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Local Signalling
4 LEDs
[Uimp] Rated Impulse Withstand Voltage
4 kV III IEC 60947-5-1 || 4 kV III DIN VDE 0110 parts 1 and 2
Net Weight
0.5 kg
Standards
EN/IEC 60947-5-1 || EN/IEC 60204-1
[Ui] Rated Insulation Voltage
300 V 2)IEC 60947-5-1 || 300 V 2)DIN VDE 0110 parts 1 and 2
Input Voltage
500 Vrms
Connections - Terminals
captive screw clamp terminals, removable terminal block flexible 0.2...1.5 mm² without cable end, 2 wires || captive screw clamp terminals, removable terminal block flexible 0.2...2.5 mm² without cable end, 1 wire || captive screw clamp terminals, removable terminal block flexible 0.25...1 mm² with cable end, without bezel, 2 wires || captive screw clamp terminals, removable terminal block flexible 0.25...2.5 mm² with cable end, with bezel, 1 wire || captive screw clamp terminals, removable terminal block flexible 0.25...2.5 mm² with cable end, without bezel, 1 wire || captive screw clamp terminals, removable terminal block flexible 0.5...1.5 mm² with cable end, with double bezel, 2 wires || captive screw clamp terminals, removable terminal block solid 0.2...1 mm² without cable end, 2 wires || captive screw clamp terminals, removable terminal block solid 0.2...2.5 mm² without cable end, 1 wire
Width
45 mm
Depth
114 mm
Input Detection Threshold
0.01...0.1 V
Breaking Capacity
1.2 A 24 V DC-13)50 ms NC relay output circuit || 1.5 A 24 V DC-13)50 ms NO relay output circuit || 10 mA 48 V solid state output circuit || 20 mA 24 V solid state output circuit
Breaking Capacity
180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1406024EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1406024EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation
-10-55 °C
Ip Degree Of Protection
IP20 terminals)EN/IEC 60529 || IP40 enclosure)EN/IEC 60529
Ambient Air Temperature For Storage
-25-85 °C