This product is part of the XC Special range, an offer of limit switches. This single-stage heavy duty screw limit switch is a device that converts a mechanical motion into an electrical control signal. It has 3 change over, snap action contacts. It is a limit switch with a conventional enclosed thermal current of 10A. It is furnished with a screw clamp terminals for electrical connection. It is an IP54 rated product. It supports 300RPM revolution speed, 40 number of turns and single pole. Its mechanical durability is about 10 million operating cycles and electrical durability is 10 million, 3 million operating cycles. This housing is made of aluminium alloy with plastic cover. It weighs 6kg. It is suitable for position control of moving parts of hoisting or materials handling equipment and liquid level control in pumping systems. It meets EN/IEC 60947-5-1 standards. Wide offer of robust rotary limit switches which connect directly to rotating shafts for medium to heavy duty applications. Special format limit switches for severe environments.
Country of Origin
FR
Part Number
XR2AA03K40
Tariff Code
85365080
EAN
3389110661637
UNSPSC
39122213
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
A total of 11 Parts In-Stock from 2 Distributors
Delivery from:
SK
SK
DE
DE
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (1)

Best offer
XR2AA03K40 product image
Schneider Electric

XR2AA03K40

Condition:
New Factory Sealed
Available:
10 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
SKTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Specifications

Range Of Product
XR and XF
Maximum Revolution Speed
300 rpm input drive shaft
Type Of Operator
drive shaft, end fittings with sprocket key and washer
Product Or Component Type
single-stage heavy duty screw limit switch
Product Specific Application
position control of moving parts of hoisting or materials handling equipment || liquid level control in pumping systems
Material
aluminium alloy body housing || plastic Cover
Theoretical Number Of Turns
40 input drive shaft
Device Short Name
XR2
Number Of Poles
1

Contractual warranty

Warranty
18 months

Complementary

Operating Finger Radius
40 mm
Length Of Developed Helical Travel
4 mm
Maximum Number Of Turns
6 threaded shaft
Repeat Accuracy
0.02 % on the tripping point
Maximum Resistance Across Terminals
25 MOhm
Actual Number Of Turns
41.697 input drive shaft)
Cable Entry
2 entries tapped for Pg 13 cable gland 9-12 mm
Short-Circuit Protection
10 A cartridge fuse gG
Net Weight
6 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Threaded Shaft Screw Pitch
4 mm
Contacts Type And Composition
3 C/O
Electrical Durability
10000000 cycles AC-15 50/60 Hz inductive 12 V, 70 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 127 V, 270 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 220 V, 290 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 24 V, 120 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 380 V, 300 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 48 V, 180 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 500 V, 300 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 12 V, 45 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 127 V, 180 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 220 V, 200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 24 V, 75 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 380 V, 200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 48 V, 120 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 500 V, 200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 12 V, 100 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 127 V, 1050 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 220 V, 1150 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 24 V, 220 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 380 V, 1150 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 48 V, 480 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 500 V, 1200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 12 V, 100 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 127 V, 700 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 220 V, 750 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 24 V, 200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 380 V, 800 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 48 V, 400 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 500 V, 800 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 110 V, 80 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 12 V, 100 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 220 V, 60 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 24 V, 90 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 440 V, 33 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 48 V, 85 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 110 V, 30 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 12 V, 45 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 220 V, 20 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 24 V, 40 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 440 V, 7.5 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 48 V, 35 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 110 V, 110 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 12 V, 100 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 220 V, 95 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 24 V, 140 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 440 V, 65 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 48 V, 130 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 110 V, 95 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 12 V, 100 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 220 V, 80 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 24 V, 120 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 440 V, 45 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 48 V, 110 W 3600 cyc/h 0.5 EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
500 V EN/IEC 60947-1 || 600 V CSA C22.2 No 14
Connections - Terminals
screw clamp terminals, 2 x 1.5 mm² with or without cable end || screw clamp terminals, 2 x 2.5 mm² without cable end
[Ie] Rated Operational Current
A300, AC-15, Ue = 240 V, Ie = 3 A EN/IEC 60947-5-1 || Q300, DC-13, Ue = 250 V, Ie = 0.27 A EN/IEC 60947-5-1
Contact Operation
snap action
Mechanical Durability
10000000 cycles
Differential Snap Over Angle
30 ° contact actuators measured at finger
Number Of Teeth
16 pinion C) || 26 pinion A) || 49 pinion B) || 59 pinion D)
[Ithe] Conventional Enclosed Thermal Current
10 A

Offer Sustainability

Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Not applicable, out of EU RoHS legal scope

Environment

Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/IEC 60947-5-1
Shock Resistance
50 gn 11 ms
Vibration Resistance
> 5 gn 10-55 Hz)
Ip Degree Of Protection
IP54 EN/IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Protective Treatment
TC