Wago

857-409

1 / 4
thumbnail
thumbnail
thumbnail
thumbnail
Part Number
857-409
Tariff Code
85437090300
UPC
4045454828493
ETIM
Group Code : EG000026
Group Description : Sensors
Class Description : Isolation amplifier
Class Code : EC002653
Version : 7
Payment methods:
Best offer from:
GBTrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 2 Parts In-Stock from 2 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (1)

857-409 product image
Condition:
New Factory Sealed
Available:
1 pc.
In-Stock
Updated at: 22-11-2024
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1

Output (Analog)

Output signal type
Current || Voltage
Output signal (voltage)
± 5 V; 0 … 5 V; 1 … 5 V; ± 10 V; 0 … 10 V; 2 … 10 V
Output signal (current)
±10 mA; 0 … 10 mA; 2 … 10 mA; ±20 mA; 0 … 20 mA; 4 … 20 mA
Load impedance (voltage output)
≥ 2 kΩ
Load impedance (current output)
≤ 600 Ω
Residual ripple
≤ 10 mV (rms)

Signal Processing

Limit frequency
100 Hz / 5 kHz (configurable via DIP switch)
Step response (typ.)
3.5 ms (100 Hz); 68 µs (5 kHz)

Configuration

Configuration options
DIP switch || Potentiometer

Environmental Requirements

Ambient temperature (operation)
-25 … +70 °C
Ambient temperature (storage)
-40 … +85 °C
Processing temperature
-25 … +50 °C
Temperature range of connection cable
≥ (Tambient + 10 K)
Relative humidity
5 … 95 % (no condensation permissible)
Operating altitude (max.)
2000 m

Connection Data

Connection technology
Push-in CAGE CLAMP®
Solid conductor
0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor
0.34 … 2.5 mm² / 22 … 14 AWG
Strip length
9 … 10 mm / 0.35 … 0.39 inches
Cable type
Shielded cable

Signaling And Communication

Configuration options
DIP switch || Potentiometer
Input signal (voltage)
±5 V; 0 … 5 V; 1 … 5 V; ±10 V; 0 … 10 V; 2 … 10 V

Supply

Power supply type
24 VDC (SELV)
Nominal supply voltage US
DC 24 V
Supply voltage range
±30 %
Current consumption (default)
≤ 20 mA
Current consumption (max.)
≤ 40 mA

Physical Data

Width
6 mm / 0.236 inches
Height
94 mm / 3.701 inches
Depth from upper-edge of DIN-rail
97.8 mm / 3.85 inches

Measurement Error

Transmission error (typ.)
≤ 0.1 % of upper-range value
Transmission error (max.)
≤ 0.2 % of upper-range value
Transmission error (under interference)
≤ 15 %
Temperature coefficient
≤ 0.01 %/K

Material Data

Fire load
0.598 MJ
Weight
38.400 g

Input

Input signal type
Voltage || Current
Input signal (voltage)
±5 V; 0 … 5 V; 1 … 5 V; ±10 V; 0 … 10 V; 2 … 10 V
Input signal (current)
±10 mA; 0 … 10 mA; 2 … 10 mA; ±20 mA; 0 … 20 mA; 4 … 20 mA
Input resistance (current input)
≤ 50 Ω
Input resistance (voltage input)
1 MΩ
Input current (max.)
50 mA
Input voltage (max.)
32 V
Zero/span adjustment
± 5 % of upper-range value

Standards And Specifications

Conformity marking
CE
EMC immunity to interference
EN 61000-6-2
EMC emission of interference
EN 61000-6-3
Standards/specifications
EN 61010-1 || EN 61373 || DNV

Mechanical Data

Mounting type
DIN-35 rail

Specifications

Product Group Code
0006

Commercial Data

Packaging type
Bag
Country of origin
DE
GTIN
4045454828493
Customs tariff number
85437090300

Notes

Safety information
Input and output must be safely isolated from any hazardous live parts!
Note
Use shielded signal lines! Only use shielded signal lines for analog input and output signals. Only then can you ensure that the accuracy and interference immunity specified for the device can be achieved, even in the presence of interference acting on the signal cable. Use in the living area is only permitted in conjunction with a power supply that meets the criteria of the living area according to EN 61000-6-3.

Test Voltage

Test voltage (input/output/supply)
AC 3 kV; 50 Hz; 1 min

Insulation Parameters

Overvoltage category
II
Pollution degree
2
Insulation type (input/analog output/supply)
Functional insulation
Insulation type (adjacent devices)
Reinforced insulation (safe isolation)