Rittal

3311491

Description

Refrigerant-based enclosure cooling in redundant version for VX IT or Micro Data Center without heating up the installation room. With two output categories 3 kW and 6.5 kW, the ideal cooling solution for smaller IT applications.
Part Number
3311491
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Benefits
Space-saving solution by installing the redundant internal unit in the VX IT server enclosure or the Micro Data Center, Maximum energy efficiency due to EC fan technology and IT-based control, Control of the server inlet temperature, The inverter-controlled compressor matches the cooling output to the current level of heat loss in the enclosure, Absorbed thermal energy is emitted directly into the ambient air at the location of the (inverter controlled) external unit , without heating up the installation room
Duty cycle
1
Function principle
["Within the internal unit, the redundant versions each have two cooling circuits and two controllers, plus two inverter-controlled external units. The fault and operating hours switchover mechanism ensures regular switching between the external units and a switchover in the event of a fault or a failure.","The device supports "front to back" air routing typical of IT applications, and regulates the server inlet temperature to the set value"]
Installation options in VX
["19" profile rails, standard or dynamic, must be off-centered by 50 mm in regards to width","The distance between the front of the 19" profile rails and the front edge of the VX frame must be at least 100 mm","Two system chassis for the inner mounting level are required to fasten the internal unit","Air baffle plates are required to separate the hot/cold zones within an enclosure","A base/plinth is needed to route cables downwards"]
Material
Carbon steel, spray finished
Max. cooling output
3 kW
Modulation range
13kW
Note
If the cooling output falls below its minimum value, fluctuations in the air intake temperature may result, The electrical connection is made to the external unit, the internal unit is supplied by the external unit, A separate power supply is required for each external unit
Packaging unit
1 pc(s).
Pre-fuse
16 A
Protection category IP to EN 60 529
Internal unit IP 20, External unit IP X4
Protection category IP to IEC 60 529
Internal unit IP 20, External unit IP X4
Rated current
7A
Rated operating voltage
230 V, 1~, 50 Hz
Refrigerant/cooling medium
Refrigerant:R410A
Supply includes
Internal unit (condenser)2 external units (inverter controlled)482.6 mm (19") mounting bracket cover with control and display elementsCondensate hose
Type of connection (electrical)
Connection clamp
Version
LCU DX 3 kW redundant
Weight/packaging unit
161 kg