Description

Active Mature
This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors both the 42 branch circuits and mains values, incoming power and energy. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with serial connection for either Modbus RTU or BACnet MS/TP, and an Ethernet connection for Modbus TCP, BACnet IP and SNMP. The meter need to be powered by a 100V AC to 277V AC supply source. Include 2 21-CTs board strips with 3/4inch (19mm) spacing between each CT connectors, for 42 circuits. The device dimensions are 353mm in width, 253mm in height, 71mm in depth and weight 1.5 kilograms.
Country of Origin
US
Part Number
BCPME042S
Tariff Code
9028300000
EAN
83101808
UNSPSC
83101808
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Environment

Height
307 mm
Standards
UL 508 || IEC 61036 || ANSI C12.1 || EN 61010
Mounting Support
enclosure || panel
Product Certifications
UL
Net Weight
1.5 kg
Mounting Mode
panel-mounted
Ambient Air Temperature For Storage
-40-70 °C
Relative Humidity
0-95 % 0-60 °C
Width
253 mm
Depth
71 mm
Operating Altitude
9842.52 ft (3000 m)

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Eu Rohs Directive
Compliant with Exemptions

Complementary

Communication Port Support
RS485 || ETHERNET
Connection Pitch
19 mm
Measurement Voltage
90-277 V phase to neutral || 150-480 V phase to phase
Sampling Rate
256 samples/cycle
Communication Port Protocol
Modbus RTU || BACnet IP || BACnet MS/TP || Modbus TCP || SNMP v2
Communication Of Data
low current alarm || low-low current alarm || under voltage alarm || high current alarm || high-high current alarm || over voltage alarm
Provided Equipment
42 x current transformer || 2 x cables
Measurement Accuracy
branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V
Update Time
1.8 s
Analogue Input Type
solid core CT 100 A42 x

Specifications

Network Frequency
60 Hz || 50 Hz
Power Quality Analysis
voltage sag and swell detection
Variant
advanced + ethernet
Type Of Measurement
voltage || current || frequency || active power || power factor || active energy
Power Monitoring
basic instrumentation
Product Or Component Type
multi-circuit energy meter
Product Name
PowerLogic BCPM
Range
PowerLogic
Energy Management
sub billing and cost allocation
[Us] Rated Supply Voltage
90...277 V AC 50/60 Hz +/- 1 %
Device Application
sub billing
Device Short Name
BCPME

Documents

Data Sheet

Download