Schneider Electric
BCPME142S
1 / 1
Description
Active Mature
This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors both the 42 branch circuits and mains values, incoming power and energy. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with serial connection for either Modbus RTU or BACnet MS/TP, and an Ethernet connection for Modbus TCP, BACnet IP and SNMP. The meter need to be powered by a 100V AC to 277V AC supply source. Include 2 21-CTs board strips with 1inch (26mm) spacing between each CT connectors, for 42 circuits. The device dimensions are 353mm in width, 253mm in height, 71mm in depth and weight 1.5 kilograms.- Part Number
- BCPME142S
- Tariff Code
- 9028300000
- EAN
- 83101808
- UNSPSC
- 83101808
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Network Frequency
- 50 Hz || 60 Hz
- Power Quality Analysis
- voltage sag and swell detection
- Variant
- advanced + ethernet
- Type Of Measurement
- voltage || current || frequency || active power || power factor || active energy
- Power Monitoring
- basic instrumentation
- Product Or Component Type
- multi-circuit energy meter
- Product Name
- PowerLogic BCPM
- Range
- PowerLogic
- Energy Management
- sub billing and cost allocation
- [Us] Rated Supply Voltage
- 90...277 V AC 50/60 Hz +/- 1 %
- Device Application
- sub billing
- Device Short Name
- BCPME
Environment
- Height
- 307 mm
- Standards
- IEC 61036 || ANSI C12.1 || UL 508 || EN 61010
- Mounting Support
- panel || enclosure
- Product Certifications
- UL
- Net Weight
- 1.5 kg
- Mounting Mode
- panel-mounted
- Ambient Air Temperature For Storage
- -40-70 °C
- Relative Humidity
- 0-95 % 0-60 °C
- Width
- 253 mm
- Depth
- 71 mm
- Operating Altitude
- 9842.52 ft (3000 m)
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Eu Rohs Directive
- Compliant with Exemptions
Complementary
- Communication Port Support
- RS485 || ETHERNET
- Connection Pitch
- 26 mm
- Measurement Voltage
- 90-277 V phase to neutral || 150-480 V phase to phase
- Sampling Rate
- 256 samples/cycle
- Communication Port Protocol
- Modbus RTU || BACnet IP || BACnet MS/TP || Modbus TCP || SNMP v2
- Communication Of Data
- low current alarm || high current alarm || over voltage alarm || high-high current alarm || low-low current alarm || under voltage alarm
- Provided Equipment
- 42 x current transformer || 2 x cables
- Measurement Accuracy
- branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V
- Update Time
- 1.8 s
- Analogue Input Type
- solid core CT 100 A42 x
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther