- Product Certifications
- IEC || CCC || EAC || UA || TR || UKCA
- Non-Overlap Time
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Minimum Switching Current
- 5 mA for signalling circuit
- Power Dissipation Per Pole
- 2.5 W AC-1 || 0.8 W AC-3 || 0.8 W AC-3e
- Average Impedance
- 2.5 mOhm - Ith 32 A 50 Hz for power circuit
- Auxiliary Contact Composition
- 1 NO + 1 NC
- [Ith] Conventional Free Air Thermal Current
- 10 A (at 60 °C) for signalling circuit || 32 A (at 60 °C) for power circuit
- Control Circuit Voltage Limits
- 0.1...0.25 Uc -40-70 °C drop-out DC || 0.7...1.25 Uc -40-70 °C operational DC
- Mounting Support
- plate || rail
- Contact Compatibility
- M5
- Control Circuit Type
- DC low consumption
- Standards
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || EN 45545: R22 HL3 || EN 45545: R26 HL3 || DIN 5510-2
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Hold-In Power Consumption In W
- 4-4 W 20 °C
- Insulation Resistance
- > 10 MOhm for signalling circuit
- Rated Breaking Capacity
- 300 A at 440 V for power circuit conforming to IEC 60947
- Irms Rated Making Capacity
- 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
- Associated Fuse Rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947
- Pole Contact Composition
- 3 NO
- Connections - Terminals
- control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 9.5 mm
- Coil Technology
- with integral suppression device
- Time Constant
- 37 ms
- Operating Time
- 55...75 ms closing || 16...32 ms opening
- Minimum Switching Voltage
- 17 V for signalling circuit
- Maximum Operating Rate
- 3600 cyc/h 60 °C
- Tightening Torque
- control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || power circuit 1.7 N.m screw clamp terminals pozidriv No 2 M3.5 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 M3.5
- Electrical Durability
- 1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V || 1.65 Mcycles 18 A AC-3e <= 440 V
- Mechanical Durability
- 30 Mcycles
- Inrush Power In W
- 4-4 W 20 °C)
- Auxiliary Contacts Type
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Compatibility Code
- LC1D
- Operating Altitude
- 0...9842.52 ft (0...3000 m)
- Overvoltage Category
- III
- Motor Power Kw
- 4 kW at 220/230 V AC 50 Hz (AC-3) || 7.5 kW at 380/400 V AC 50 Hz (AC-3) || 9 kW at 415 V AC 50 Hz (AC-3) || 9 kW at 440 V AC 50 Hz (AC-3) || 10 kW at 500 V AC 50 Hz (AC-3) || 10 kW at 660/690 V AC 50 Hz (AC-3) || 4 kW at 220/230 V AC 50 Hz (AC-3e) || 7.5 kW at 380/400 V AC 50 Hz (AC-3e) || 9 kW at 415 V AC 50 Hz (AC-3e) || 9 kW at 440 V AC 50 Hz (AC-3e) || 10 kW at 500 V AC 50 Hz (AC-3e) || 10 kW at 660/690 V AC 50 Hz (AC-3e)
- [Ui] Rated Insulation Voltage
- power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1
- Protective Cover
- with