Description
Active Mature
TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 10A, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).- Country of Origin
- FR
- Part Number
- LRD103
- Tariff Code
- 85364900
- EAN
- 3389110822052
- UNSPSC
- 39122330
£38.93
net1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 3 pcs.In-StockUpdated at: 21-11-2024
- Estimated Delivery:
- On Request
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Environment
- Product Certifications
- IEC || UL || CSA || CCC || EAC || BV || RINA || DNV-GL || LROS (Lloyds register of shipping) || ATEX INERIS || UKCA
- Mechanical Robustness
- vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
- Standards
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5 || EN 50495
- Climatic Withstand
- IACS E10
- Ambient Air Temperature For Operation
- -20-60 °C without derating IEC 60947-4-1
- Dielectric Strength
- 1.89 kV 50 Hz IEC 60947-1
- Ip Degree Of Protection
- IP20 conforming to IEC 60529
- Flame Retardance
- V1 conforming to UL 94
- Ambient Air Temperature For Storage
- -60-70 °C
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Environmental Disclosure
- ENVPEP080405EN
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI0804005_V1
- Eu Rohs Directive
- Compliant with Exemptions
Complementary
- Network Frequency
- 0...400 Hz
- Height
- 93 mm
- [Ith] Conventional Free Air Thermal Current
- 5 A signalling circuit
- Auxiliary Contact Composition
- 1 NO + 1 NC
- Connections - Terminals
- control circuit spring terminals 1 1-2.5 mm² solid without cable end || control circuit spring terminals 1 1-2.5 mm² flexible without cable end || power circuit spring terminals 1 1.5-4 mm² flexible without cable end || power circuit spring terminals 1 1.5-4 mm² flexible with cable end
- Phase Failure Sensitivity
- tripping current 130 % of Ir on two phase, the last one at 0
- [Ue] Rated Operational Voltage
- 690 V AC 0...400 Hz power circuit IEC 60947-4-1
- Associated Fuse Rating
- 4 A gG for signalling circuit || 4 A BS for signalling circuit
- Net Weight
- 0.14 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV
- Permissible Current
- 3 A 120 V AC-15 signalling circuit || 0.22 A 125 V DC-13 signalling circuit
- Tripping Threshold
- 1.14 +/- 0.06 Ir IEC 60947-4-1
- Control Type
- Red push-button stop || Blue push-button reset
- Mounting Support
- plate, with specific accessories || rail, with specific accessories || under contactor
- Width
- 45 mm
- Depth
- 72 mm
- Temperature Compensation
- -20-60 °C
Specifications
- Network Type
- DC || AC
- Thermal Protection Adjustment Range
- 4-6 A
- Relay Application
- motor protection
- Product Or Component Type
- differential thermal overload relay
- Product Name
- TeSys LRD || TeSys Deca
- Thermal Overload Class
- class 10A IEC 60947-4-1
- Range
- TeSys || TeSys Deca
- [Ui] Rated Insulation Voltage
- power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Product Compatibility
- LC1D32 || LC1D12 || LC1D25 || LC1D38 || LC1D09 || LC1D18
- Device Short Name
- LRD
CAD Models
traceparts
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther