Schneider Electric
LX1G3QLSEA
1 / 1
Description
Active Mature
It is a 200-500V AC/DC control module for 3 poles TeSys Giga 115-225 contactor (advanced version). Coil designed for less energy consumption and wider voltage band-width, connection by spring terminal. It allows contactor operation with high AC-3 operating rates until 600 cycles/hour and environments until 60°C. Control module has connectors for connecting the coil control A1, A2 circuit & PLC output control, pole status and diagnostic signaling circuits. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It is accessible from the front and maintained with very low down times. Unique QR code provides quick access to complete product data.- Country of Origin
- CN
- Part Number
- LX1G3QLSEA
- Tariff Code
- 85059090
- EAN
- 3606481946188
- UNSPSC
- 39121010
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 5 pcs.In-StockUpdated at: 22-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Environment
- Ambient Air Temperature For Operation
- -25-60 °C
- Height
- 144.5 mm
- Standards
- EN/IEC 60947-4-1 || UL 60947-4-1A || CSA C22.2 No 60947-4-1
- Electromagnetic Compatibility
- EMC immunity conforming to IEC 60947-4-1 || emission tests criteria A conforming to IEC 60947-4-1 || immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 || voltage dips and interruptions immunity test conforming to SEMI F47
- Ip Degree Of Protection
- IP20 IEC 60529
- Pollution Degree
- 3 IEC 60947-1
- Ambient Air Temperature For Storage
- -60-80 °C
- Operating Altitude
- 9842.52 ft (3000 m) without derating || 5000 m with derating factor
- Quantity Per Set
- 1
- Width
- 105.7 mm
- Depth
- 94.0 mm
- Permissible Ambient Air Temperature Around The Device
- -40-70 °C at Uc
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP2105013
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI2105013
- Eu Rohs Directive
- Compliant with Exemptions
- Halogen Content Performance
- Halogen free plastic parts product
Specifications
- [Uc] Control Circuit Voltage
- 200...500 V AC/DC 50/60 Hz
- Range Compatibility
- TeSys G LX1G contactor coil
- Product Or Component Type
- contactor coil
- Range
- TeSys
- Maximum Operating Rate
- 600 cyc/mn 60 °C
- Poles Description
- 3P
- Operating Time
- 20...35 ms opening || 40...55 ms closing
- Product Compatibility
- LC1G115...225
- Device Short Name
- LX1G
- Mechanical Durability
- 5 Mcycles
Complementary
- Control Circuit Voltage Limits
- operational 0.8...1.1 Uc 60 °C) || drop-out 0...0.45 Uc 60 °C)
- Hold-In Power Consumption In W
- 3.4-3.4 W DC
- Inrush Power In Va
- 255-255 VA 480 V AC, 60 Hz
- Connections - Terminals
- control circuit push-in termination 1 0.2-2.5 mm² solid stranded without cable end sleeve AWG 26...AWG 12 || control circuit push-in termination 1 0.25-2.5 mm² flexible with cable end sleeve AWG 24...AWG 14 || control circuit push-in termination 2 0.5-1.0 mm² rigid or stranded with cable end sleeve AWG 20...AWG 18
- Coil Technology
- built-in bidirectional peak limiting
- Hold-In Power Consumption In Va
- 13.4-13.4 VA 480 V AC, 60 Hz
- Inrush Power In W
- 155.0 W DC
CAD Models
traceparts