Schneider Electric
RM35TF30SP01
1 / 1
Description
Active Mature
- Country of Origin
- ID
- Part Number
- RM35TF30SP01
- Tariff Code
- 8536490075
- EAN
- 39122329
- UNSPSC
- 39122329
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 1 pc.In-StockUpdated at: 22-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Specifications
- Range Of Product
- Harmony Relay
- Measurement Range
- 194...528 V AC
- Switching Capacity In Va
- 1250 VA
- Product Or Component Type
- modular measurement and control relays
- Relay Name
- RM35TF
- Relay Type
- multifunction control relay
- Product Specific Application
- for 3-phase supply
- Time Delay Type
- adjustable 0.1...10 s, +/- 10 % of the full scale value
- Relay Monitored Parameters
- phase sequence || asymmetry || undervoltage and overvoltage in window mode || phase failure detection
Contractual warranty
- Warranty
- 18 months
Complementary
- Voltage Range
- 220...480 V phase to phase
- Safety Reliability Data
- B10d = 360000 || MTTFd = 399.5 years
- Minimum Switching Current
- 10 mA 5 V DC
- Maximum Measuring Cycle
- 140 ms measurement cycle as true rms value
- Control Circuit Voltage Limits
- 12 % + 10 % Un
- Maximum Switching Current
- 5 A AC || 5 A DC
- Hysteresis
- 2-2 %
- Insulation Resistance
- > 500 MOhm 500 V DC IEC 60255-5 || > 500 MOhm 500 V DC IEC 60664-1
- Measurement Error
- < 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation
- Operating Rate
- <= 360 operations/hour full load
- Power Consumption In Va
- 0-22 VA 400 V AC 50 Hz
- Output Contacts
- 2 C/O
- Voltage Detection Threshold
- < 194 V
- Adjustment Of Asymmetry Threshold
- 5...15 % of Un selected
- Marking
- CE
- Response Time
- < 200 ms (in the event of a fault)
- Operating Position
- any position without derating
- Utilisation Category
- AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1
- Net Weight
- 0.13 kg
- Maximum Switching Voltage
- 250 V AC || 250 V DC
- Reset Time
- 1500 ms at 480 V
- Connections - Terminals
- screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
- [Ui] Rated Insulation Voltage
- 400 V IEC 60664-1
- Overvoltage Category
- III IEC 60664-1
- Supply Voltage Limits
- 194-528 V AC, 3 phase
- Mounting Support
- 35 mm symmetrical DIN rail conforming to EN/IEC 60715
- Nominal Output Current
- 5 A
- Local Signalling
- for power ON LED (green) || for relay ON LED (yellow) || for fault LED (yellow)
- Mechanical Durability
- 30000000 cycles
- Housing Material
- self-extinguishing plastic
- Control Circuit Frequency
- 50...60 Hz +/- 10 %
- Threshold Adjustment Voltage
- 2...20 % of Un selected || -12...-2 % in the range 220 V AC || +2...+10 % in the range 480 V AC || -20...-2 % in the range 380...480 V AC || +2...+20 % in the range 220...440 V AC
- Width
- 35 mm
- Tightening Torque
- 0.6-1 N.m IEC 60947-1
- Electrical Durability
- 100000 cycles
- Run-Up Delay At Power-Up
- 650 ms
- Supply Frequency
- 50/60 Hz +/- 10 %
- Repeat Accuracy
- 0.3 % time delay || 0.5 % input and measurement circuit
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1504008EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1504008EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CSA || C-tick || GL || GOST || UL
- Standards
- EN/IEC 60255-1
- Non-Dissipating Shock Wave
- 4 kV
- Dielectric Test Voltage
- 2 kV AC 50 Hz, 1 min
- Electromagnetic Compatibility
- emission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments EN/IEC 61000-6-2
- Shock Resistance
- 15 gn 11 ms IEC 60255-21-1
- Ambient Air Temperature For Operation
- -20-50 °C
- Vibration Resistance
- 0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
- Ip Degree Of Protection
- IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
- Pollution Degree
- 3 IEC 60664-1
- Directives
- 89/336/EEC - electromagnetic compatibility || 73/23/EEC - low voltage directive
- Ambient Air Temperature For Storage
- -40-70 °C
- Relative Humidity
- 95-95 % 55-55 °C IEC 60068-2-30
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther