Specifications

Type Of Approach
lateral approach, 2 directions
Series Name
standard format
Contacts Type And Composition
2 x (1 NC + 1 NO)
Movement Of Operating Head
linear
Body Type
fixed
Range Of Product
Telemecanique Limit switches XC Standard
Contact Operation
slow-break, break before make
Fixing Mode
by the body
Type Of Operator
spring return roller plunger metal
Body Material
zamak
Cable Entry
3 entries tapped for Pg 13.5 cable gland 9-12 mm
Product Or Component Type
limit switch
Material
metal
Device Short Name
XCKML
Number Of Poles
4
Head Type
plunger head

Contractual warranty

Warranty
18 months

Complementary

Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Height
81-81 mm
Terminals Description Iso N°1
(21-22)NC || (13-14)NO
Electrical Durability
5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force
50 N
Positive Opening
with
Minimum Actuation Speed
6 m/min
Contacts Insulation Form
Zb
Electrical Connection
screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Mechanical Durability
3000000 cycles
Maximum Actuation Speed
0.5 m/s
Minimum Force For Tripping
12 N
Width
77 mm
Depth
36 mm
Number Of Steps
1
Net Weight
0.405 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
[Ithe] Conventional Enclosed Thermal Current
10 A AC
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Environmental Disclosure
ENVPEP110614EN
Eu Rohs Directive
Not applicable, out of EU RoHS legal scope
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
UL || CSA
Ik Degree Of Protection
IK05 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
UL 508 || EN 60947-5-1 || IEC 60204-1 || IEC 60947-5-1 || EN 60204-1 || CSA C22.2 No 14
Electrical Shock Protection Class
class I IEC 61140 || class I NF C 20-030
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)EN/IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529