This pressure transmitter is part of the XMLP range, an offer of electronic pressure sensors. The XMLP transmitters are designed for the vacuum measuring and the pressure measuring. They are compatible with a large number of fluids. This product has a pressure range of 0psi to 300psi, with a maximum permissible accidental pressure at 900psi and a destruction pressure at 2200psi. Made of stainless steel, this transmitter is compact and rugged. It has an analogue output (4mA to 20mA), wich delivers a signal proportional to the measured pressure. It is appropriate for controlling air, fresh water, hydraulic oil, gas and refrigeration fluid. This pressure transmitter features a compact metal body, a 1/4-18NPT (male) 316L stainless steel fluid connector and a M12 electrical connector. It is suitable for machine tools, moulding presses, stamping presses and lifting gear. It complies with RCM, CULus, CE, EAC certifications, and with NSF ANSI 61 and EN/IEC 61326-2-3 standards. Dedicated accessories, to be ordered separatly, are available to facilitate the setting of the transmitter. Switches with a display, sealing gaskets, pre-wired connectors, etc. This transmitter is sold in lots of 25. It operates in all positions. The transmitters of the XMLP range integrate a ceramic pressure measuring cell, providing a high level of sensitivity and good resistance to abrasive fluids.
Country of Origin
CH
Part Number
XMLP300PD230Q
Tariff Code
9026204000
EAN
41111927
UNSPSC
41111927
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Pressure Sensor Type
pressure transmitter
Analogue Output Function
4...20 mA, 2-wire
Type Of Output Signal
analogue
Controlled Fluid
fresh water 0-135 °C) || air -40-135 °C) || hydraulic oil -40-135 °C) || gas -40-135 °C) || refrigeration fluid -40-135 °C)
Range Of Product
Telemecanique Pressure sensors XM
Electrical Connection
1 male connector M12 4 pins
Pressure Sensor Size
300-300 psi
Quantity Per Set
set of 25
Electrical Circuit Type
control circuit
Product Or Component Type
electronic pressure sensors
Type Of Packing
group
[Us] Rated Supply Voltage
12...24 V DC SELV 7-33 V)
Local Display
without
Pressure Sensor Name
XMLP
Current Consumption
< 23 mA
Fluid Connection Type
1/4" - 18 NPT (male)

Complementary

Accuracy
0.1 % of the measuring range
Diameter
26 mm
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Mechanical Durability
10000000 cycles
Drift Of The Zero Point
+/- 0.02 % of measuring range/°K
Operating Position
any position
Electromagnetic Compatibility
electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 4 kV contact || 1.2/50 µs shock waves immunity test EN/IEC 61000-4-5 1 kV 42 Ohm || immunity to magnetic fields EN/IEC 61000-4-8 100 A/m 50 Hz || electrical fast transient/burst immunity test EN/IEC 61000-4-4 4 kV || susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...3000 MHz || radiated RF fields EN/IEC 61000-4-6 10 V 0.01...80 MHz
Measurement Accuracy
+/- 0.5 % of the measuring range
Protection Type
reverse polarity || load short-circuit
Drift Of The Sensitivity
+/- 0.02 % of measuring range/°K
Maximum Permissible Accidental Pressure
900 psi
Materials In Contact With Fluid
stainless steel AISI 316L
Length
36 mm
Destruction Pressure
2200 psi
Net Weight
0.088 kg
Response Time On Output
<= 2 ms 10...90 % of full scale
Pressure Setting Range
0-300 psi

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1511013EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
RCM || cULus || CE || EAC
Ambient Air Temperature For Operation
-30-85 °C
Ambient Air Temperature For Storage
-50-100 °C
Standards
EN/IEC 61326-2-3 || NSF ANSI 61
Shock Resistance
100 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
20 gn 15-2000 Hz) EN/IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529 || IP69K conforming to EN/IEC 60529