Main

Commercial Status
Commercialised
Range
TeSys
Product name
TeSys D
Product or component type
Reversing contactor
Device short name
LC2D
Contactor application
Motor control
Contactor application
Resistive load
Utilisation category
AC-1
Utilisation category
AC-3
Device presentation
Preassembled with reversing power busbar
Poles description
3P
Pole contact composition
3 NO
[Ie] rated operational current
12 A (25 A (
Motor power kW
7.5 kW at 660...690 V AC 50/60 Hz
Motor power kW
7.5 kW at 500 V AC 50/60 Hz
Motor power kW
5.5 kW at 415...440 V AC 50/60 Hz
Motor power kW
5.5 kW at 380...400 V AC 50/60 Hz
Motor power kW
3 kW at 220...230 V AC 50/60 Hz
Motor power hp
10 hp at 575/600 V AC 50/60 Hz 3 phases motors
Motor power hp
7.5 hp at 460/480 V AC 50/60 Hz 3 phases motors
Motor power hp
3 hp at 230/240 V AC 50/60 Hz 3 phases motors
Motor power hp
3 hp at 200/208 V AC 50/60 Hz 3 phases motors
Motor power hp
2 hp at 230/240 V AC 50/60 Hz 1 phase motors
Motor power hp
1 hp at 115 V AC 50/60 Hz 1 phase motors
Control circuit type
AC 50/60 Hz
Control circuit voltage
480 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
Overvoltage category
III
[Ith] conventional free air thermal current
25 A at 10 A at
Irms rated making capacity
250 A DC signalling circuit conforming to IEC 60947-5-1
Irms rated making capacity
140 A AC signalling circuit conforming to IEC 60947-5-1
Irms rated making capacity
250 A at 440 V power circuit conforming to IEC 60947
Rated breaking capacity
250 A at 440 V power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
140 A 100 ms signalling circuit
[Icw] rated short-time withstand current
120 A 500 ms signalling circuit
[Icw] rated short-time withstand current
100 A 1 s signalling circuit
[Icw] rated short-time withstand current
210 A 105 A 61 A 30 A
Associated fuse rating
25 A gG at 40 A gG at 10 A gG signalling circuit conforming to IEC 60947-5-1
Average impedance
2.5 mOhm at 50 Hz - Ith 25 A power circuit
[Ui] rated insulation voltage
600 V signalling circuit certifications UL
[Ui] rated insulation voltage
600 V signalling circuit certifications CSA
[Ui] rated insulation voltage
690 V signalling circuit conforming to IEC 60947-1
[Ui] rated insulation voltage
600 V power circuit certifications UL
[Ui] rated insulation voltage
600 V power circuit certifications CSA
[Ui] rated insulation voltage
690 V power circuit conforming to IEC 60947-4-1
Electrical durability
0.8 Mcycles 25 A AC-1 at Ue 2 Mcycles 12 A AC-3 at Ue
Power dissipation per pole
0.36 W AC-3
Power dissipation per pole
1.56 W AC-1
Protective cover
With
Interlocking type
Mechanical
Mounting support
Plate
Mounting support
Rail
Standards
EN 60947-4-1
Standards
EN 60947-5-1
Standards
IEC 60947-4-1
Standards
IEC 60947-5-1
Standards
UL 508
Standards
CSA C22.2 No 14
Product certifications
BV
Product certifications
CCC
Product certifications
CSA
Product certifications
DNV
Product certifications
GL
Product certifications
GOST
Product certifications
RINA
Product certifications
UL
Product certifications
LROS
Connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
Connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
Connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
Connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end
Connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
Connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
Connections - terminals
Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
Connections - terminals
Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
Connections - terminals
Power circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
Connections - terminals
Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end
Connections - terminals
Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
Connections - terminals
Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
Tightening torque
Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2
Tightening torque
Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
Tightening torque
Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2
Tightening torque
Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
Operating time
4...19 ms opening
Operating time
12...22 ms closing
Safety reliability level
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Mechanical durability
15 Mcycles
Operating rate
3600 cyc/h at

Complementary

Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.85...1.1 Uc at 140 °F (60 °C) operational 60 Hz
Control circuit voltage limits
0.8...1.1 Uc at 140 °F (60 °C) operational 50 Hz
Control circuit voltage limits
0.3...0.6 Uc at 140 °F (60 °C) drop-out 50/60 Hz
Inrush power in VA
70 VA at 68 °F (20 °C) (cos ϕ 0.75) 50 Hz
Inrush power in VA
70 VA at 68 °F (20 °C) (cos ϕ 0.75) 60 Hz
Hold-in power consumption in VA
7 VA at 68 °F (20 °C) (cos ϕ 0.3) 50 Hz
Hold-in power consumption in VA
7.5 VA at 68 °F (20 °C) (cos ϕ 0.3) 60 Hz
Heat dissipation
2...3 W at 50/60 Hz
Auxiliary contacts type
Type mirror contact (1 NC) conforming to IEC 60947-4-1
Auxiliary contacts type
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Signalling circuit frequency
25...400 Hz
Minimum switching current
5 mA signalling circuit
Non-overlap time
1.5 ms on energisation (between NC and NO contact)
Non-overlap time
1.5 ms on de-energisation (between NC and NO contact)
Insulation resistance
> 10 MOhm signalling circuit

Environment

IP degree of protection
IP2x front face conforming to IEC 60529
Protective treatment
TH conforming to IEC 60068-2-30
Pollution degree
3
Ambient air temperature for operation
-4 To 140 °F (-20 To 60 °C)
Ambient air temperature for storage
-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device
-40...158 °F (-40...70 °C) at Uc
Operating altitude
9842.52 ft (3000 m) without derating in temperature
Fire resistance
1562 °F (850 °C) conforming to IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Shocks contactor closed 15 Gn for 11 ms
Mechanical robustness
Shocks contactor open 10 Gn for 11 ms
Mechanical robustness
Vibrations contactor closed 4 Gn, 5...300 Hz
Mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz
Height
3.03 in (77 mm)
Width
3.54 in (90 mm)
Depth
3.39 in (86 mm)
Product weight
1.54 lb(US) (0.697 kg)

Ordering and Shipping Details

Category
22346 - CTR,D-LINE,OPEN,REVERSING-NEW
Discount Schedule
I12
GTIN
00785901542872
Nbr. of units in pkg.
1
Product availability
Non-Stock - Not normally stocked in distribution facility
Returnability
N
Country of origin
FR

Offer Sustainability

Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Compliant - since 0627 -
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Available
Product environmental profile
Download Product Environmental Profile
Product end of life instructions
Need no specific recycling operations

Contractual Warranty

Warranty period
18 months

Documents

Data Sheet

Download