TE Connectivity
OSA-SH-212DM5,000
1 / 1
- Part Number
- OSA-SH-212DM5,000
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Packaging Features
- Packaging Method
- Box/Carton
Dimensions
- Insulation Clearance Class
- 5 – 8mm
- Length Class (Mechanical) (mm)
- 20 – 25
- Width
- 12.9 mm [ .508 in ]
- Height
- 24.8 mm [ .976 in ]
- Height Class (Mechanical) (mm)
- 20 – 25
- Width Class (Mechanical) (mm)
- 12 – 16
- Insulation Clearance Between Contact and Coil
- 7 mm [ .276 in ]
- Length
- 24.4 mm [ .961 in ]
Mechanical Attachment
- Mounting Type
- Printed Circuit Board
Usage Conditions
- Environmental Category of Protection
- RTIII
- Environmental Ambient Temperature (Max)
- 60 °C [ 140 °F ]
- Environmental Ambient Temperature Class
- 50 – 70°C
Contact Features
- Contact Number of Poles
- 2
- Contact Material
- AgNi90/10
- Contact Current Rating (A)
- 5
- Contact Arrangement
- 2 Form A (NO)
- Contact Current Class
- 2 – 5 A, Less Than 16A
- Terminal Type
- PCB-THT
Body Features
- Weight
- 13 g [ .459 oz ]
- Insulation Special Features
- 7000V Initial Surge Withstand Voltage between Contacts & Coil
Product Type Features
- Relay Type
- Miniature PCB Relay
- Product Type
- Relay
Electrical Characteristics
- Insulation Creepage Class
- 5.5 – 8mm
- Contact Limiting Short-Time Current (A)
- 5
- Coil Magnetic System
- Monostable, DC
- Insulation Initial Resistance (MΩ)
- 1000
- Insulation Creepage Between Contact and Coil
- 7 mm [ .276 in ]
- Coil Power Rating (DC) (mW)
- 540
- Coil Resistance (Ω)
- 270
- Insulation Initial Dielectric Between Open Contacts (Vrms)
- 1000
- Insulation Initial Dielectric Between Adjacent Contacts (Vrms)
- 2500
- Coil Power Rating Class
- 500 – 600 mW
- Contact Switching Voltage (Max)
- 240 VAC [ 30 VDC ]
- Contact Switching Load (Min)
- 100mA @ 5V
- Insulation Initial Dielectric Between Contacts and Coil (Vrms)
- 4000
- Contact Limiting Making Current (A)
- 5
- Coil Special Features
- UL Coil Insulation Class A
- Contact Voltage Rating (VAC)
- 240
- Contact Limiting Breaking Current (A)
- 5
- Insulation Initial Dielectric Between Coil/Contact Class
- 3500 – 4000 V
- Coil Voltage Rating (VDC)
- 12
- Contact Limiting Continuous Current (A)
- 5
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther