Wago
2206-1621/1000-836
1 / 1
- Part Number
- 2206-1621/1000-836
- Tariff Code
- 85369095000
- UPC
- 4066966306613
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Ratings Per Iec/En
- Ratings per
- IEC/EN 60947-7-3
- Ratings (note)
- Electrical ratings are given by the fuse and blown fuse indication.
- Nominal voltage (III/3)
- 800 V
- Rated impulse voltage (III/3)
- 8 kV
- Rated current
- 10 A
- Note (rated current)
- Leakage current in case of a blown fuse: LED 2 mA
- Operation status indicator
- 230 V
- Legend (ratings)
- (III / 3) ≙ Overvoltage category III / Pollution degree 3
Environmental Requirements
- Processing temperature
- -35 … +85 °C
- Continuous operating temperature
- -60 … +105 °C
Physical Data
- Width
- 7.5 mm / 0.295 inches
- Height
- 96.3 mm / 3.791 inches
- Depth from upper-edge of DIN-rail
- 59 mm / 2.323 inches
Material Data
- Note (material data)
- <a href="https://www.wago.com/us/material-specifications" href="_blank">Information on material specifications can be found here</a>
- Color
- Gray
- Material group
- I
- Insulation material
- Polyamide (PA66)
- Flammability class per UL94
- V0
- Fire load
- 0.474 MJ
- Weight
- 25.226 g
Mechanical Data
- Mounting type
- DIN-35 rail
- Marking level
- Center/side marking
General
- Fuse receptacle
- Pivoting
- Fuse type
- Cylindrical fuse; 5 x 30 mm
Specifications
- Product Group Code
- 0036
Commercial Data
- Country of origin
- PL
- GTIN
- 4066966306613
- Customs tariff number
- 85369095000
Ratings Per Csa
- Approvals per
- CSA 22.2 No 158
- Rated voltage CSA (Use Group B)
- 600 V
- Rated current CSA (Use Group B)
- 15 A
- Rated voltage CSA (Use Group C)
- 600 V
- Rated current CSA (Use Group C)
- 15 A
Power Loss
- Power loss Pl max. overload and short-circuit protection (individual arrangement)
- 1.6 W
- Power loss Pl max. overload and short-circuit protection (group arrangement)
- 1.6 W
- Power loss Pl max. short-circuit protection (individual arrangement)
- 2.5 W
- Power loss Pl max. short-circuit protection (group arrangement)
- 2.5 W
Connection 1
- Connection technology
- Push-in CAGE CLAMP®
- Actuation type
- Push-button
- Connectable conductor materials
- Copper
- Nominal cross-section
- 6 mm²
- Solid conductor
- 0.5 … 10 mm² / 20 … 8 AWG
- Solid conductor; push-in termination
- 1 … 10 mm² / 14 … 8 AWG
- Fine-stranded conductor
- 0.5 … 10 mm² / 20 … 8 AWG
- Fine-stranded conductor; with insulated ferrule
- 0.5 … 6 mm² / 20 … 10 AWG
- Fine-stranded conductor; with ferrule; push-in termination
- 2.5 … 6 mm² / 16 … 10 AWG
- Note (conductor cross-section)
- Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
- Strip length
- 13 … 15 mm / 0.51 … 0.59 inches
- Wiring direction
- Front-entry wiring
Ratings Per Ul 1059
- Approvals per
- UL 1059
- Rated voltage UL (Use Group B)
- 230 V
- Rated current UL (Use Group B)
- 15 A
- Rated voltage UL (Use Group C)
- 230 V
- Rated current UL (Use Group C)
- 15 A
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther