Wago

767-5801/000-800

1 / 4
thumbnail
thumbnail
thumbnail
thumbnail
Part Number
767-5801/000-800
Tariff Code
85389091890
UPC
4050821374299
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Environmental Requirements

Ambient temperature (operation)
-25 … +60 °C
Ambient temperature (storage)
-40 … +85 °C
Protection type
IP67
Protection class
III
Operating altitude
−1000 … 2000 m; Air pressure: 1080 … 795 hPa
Relative humidity (without condensation)
95 %
Vibration resistance
5g per IEC 60068-2-6
Shock resistance
Short-term: 50g/11 ms/half-sine per IEC 60068-2-27; Long-term: 30g/6 ms/half-sine per IEC 60068-2-29
EMC immunity to interference
Per EN 61000-6-2
EMC emission of interference
Per EN 61000-6-4
Permissible H2S contaminant concentration at a relative humidity 75 %
0.1 ppm
Permissible SO2 contaminant concentration at a relative humidity 75 %
0.5 ppm

Connection Data

Connection technology: inputs/outputs
8 x M8 socket; 3-pole
Connection technology: field supply
1 x M12 plug; 4-pole; A-coded; 1 x M12 socket; 4-pole; A-coded
Connection technology: system supply
1 x M12 socket; 4-pole; A-coded; 1 x M12 plug; 4-pole; A-coded
Connection technology: system bus
1 x M12 socket, 5-pole, B-coded, shielded; 1 x M12 plug, 5-pole, B-coded, shielded
Connection requirement (permissible cable length)
30 m
Connection requirement (permissible cable type)
Digital inputs/outputs: unshielded

Physical Data

Width
50 mm / 1.969 inches
Height
35.7 mm / 1.406 inches
Depth
117 mm / 4.606 inches

Material Data

Color
Light gray
Housing material
Polyamide (PA), Makrolon (address switch cover), flammability per UL94-V0, halogen/silicon-free
Fire load
0.016 MJ
Weight
275.000 g
Conformity marking
CE
Encapsulation
Polyurethane (PUR), halogen/silicon-free

Technical Data

Number of digital inputs
8
Number of digital outputs
8
Number of configurable digital inputs/outputs
8
Number of counters
2
Total number of channels (module)
8
Signal type
Voltage
Signal type (voltage)
24 VDC
Counter type
Event/peak-time counter, pulse duration
Counting/switching frequency
0 Hz … 1 kHz
Sensor connection
8 x (2-wire, 3-wire)
Actuator connection
8 x (2-wire, 3-wire)
Input characteristic
High-side switching || Type 1, per IEC 61131-2
Input filter (digital)
0.1 ms || 0.5 ms || 3 ms || 15 ms || 20 ms
Input filter
Hardware: ≤ 110 µs; Software: parameterizable
Input current per channel for signal (0) max.
0.6 mA
Input current per channel for signal (1) typ.
3 mA
Input current per channel for signal (1) min.
2.6 mA
Input current per channel for signal (1) max.
3.2 mA
Output characteristic
High-side switching
Output current per channel
0.5 A
Output current (module)
4 A
Output current
Short-circuit/overload-protected
Leakage current in OFF state
5 µA
Switching frequency (max.)
500 Hz; Inductive load
Switching frequency (max.) (2)
20 Hz; Resistive load
Switching frequency (max.) (3)
500 Hz; Lamp load
Load type
Resistive, inductive, lamp load
Voltage range for signal (0)
−3 … +5 VDC
Voltage range for signal (1)
15 … 30 VDC
Load type of switching frequency
Inductive load
Process data width
Depends on operating mode
Parameterizable functions
I/O diagnostics (per module): Short circuit (sensor/actuator supply); Undervoltage (ULS + UA) || I/O diagnostics (per channel): Overtemperature || Online simulation (per module): Diagnostics || Online simulation (per channel): Lock/Unlock; Simulation value: 0/1; Diagnostics || Operating mode (per module): DO module/DI module/DIO module/DIO module + 1 counter/DIO module + 2 counters || Input filter (per channel): 0.1/ 0.5/ 3 /15 /20 ms/ Filter "Off" || Inversion (per channel): On/Off || Substitute value (per channel): 0/1 || Substitute value strategy (per channel): Switch substitute value/Hold last value || Manual mode (per channel): On/Off || Manual mode value (by channel): 0/1
Protection
Reverse voltage protection for ULS + Uo; Short circuit protection for sensor/actuator supply
Output resistance
0.4 Ω
Supply voltage (system and sensor)
24 VDC(-25 … +30 %); Logic and sensors (ULS)
Current consumption (system and sensor)
45 mA
System and sensor power consumption (note)
Logic component only
Supply voltage (field)
24 VDC (-25 … +30 %); Actuators (UA)
Current consumption, field supply (module with no external load)
75 mA
Isolation
500 V supply/system bus
Interference-free with safety function
Yes
Indicators
LED (F) red: Error status; LED (SB) green/red/orange: System bus status; LED (ULS, UA) green: Power supply status; LED (0 … 7) yellow/red: Status/diagnostics DI/DO 1 … DI/DO 8; Non-retentive displays
Current carrying capacity (supply connections)
8 A
Drop-out time from “1” to “0”
Typ. 45 µs (resistive load)
Connection of 2-wire BEROs
Admissible closed current: 1.5 mA (max.)
Rise time from “0” to “1”
Typ. 60 µs (resistive load)
Output operation
Non-retentive
Protection against reverse voltages
0.5 A
Voltage drop against UA
0.2
S-bus (system bus) disruption
0 V status

Specifications

Product Group Code
0015

Commercial Data

Packaging type
Box
Country of origin
DE
GTIN
4050821374299
Customs tariff number
85389091890