Wago
767-6403
1 / 4
- Part Number
- 767-6403
- Tariff Code
- 85389099990
- UPC
- 4045454951108
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Environmental Requirements
- Ambient temperature (operation)
- -25 … +60 °C
- Ambient temperature (storage)
- -40 … +85 °C
- Protection type
- IP67
- Protection class
- III
- Operating altitude
- −1000 … 2000 m; Air pressure: 1080 … 795 hPa
- Relative humidity (without condensation)
- 95 %
- Vibration resistance
- 5g per IEC 60068-2-6
- Shock resistance
- Short-term: 50g/11 ms/half-sine per IEC 60068-2-27; Long-term: 30g/6 ms/half-sine per IEC 60068-2-29
- EMC immunity to interference
- Per EN 61000-6-2
- EMC emission of interference
- Per EN 61000-6-4
Connection Data
- Connection technology: inputs/outputs
- 4 x M12 socket; 5-pole; A-coded
- Connection technology: field supply
- 1 x M12 plug; 4-pole; A-coded; 1 x M12 socket; 4-pole; A-coded
- Connection technology: system supply
- 1 x M12 socket; 4-pole; A-coded; 1 x M12 plug; 4-pole; A-coded
- Connection technology: system bus
- 1 x M12 socket, 5-pole, B-coded, shielded; 1 x M12 plug, 5-pole, B-coded, shielded
- Connection requirement (permissible cable length)
- 30 m
- Connection requirement (permissible cable type)
- Analog inputs: unshielded
Physical Data
- Width
- 50 mm / 1.969 inches
- Height
- 35.7 mm / 1.406 inches
- Depth
- 117 mm / 4.606 inches
Material Data
- Housing material
- Polyamide (PA), Makrolon (address switch cover), flammability per UL94-V0, halogen/silicon-free
- Fire load
- 0.009 MJ
- Weight
- 263.000 g
- Conformity marking
- CE
- Encapsulation
- Polyurethane (PUR), halogen/silicon-free
Technical Data
- Number of analog inputs
- 4
- Total number of channels (module)
- 4
- Signal type
- Thermocouple || Low voltages
- Signal type (configurable)
- Yes
- Sensor connection
- 4 x (2-wire); External shield via knurled nut
- Resolution [bit]
- 16 bits
- Process data width
- 8-byte data + status
- Parameterizable functions
- I/O diagnostics (per module): Undervoltage (ULS + UA) || I/O diagnostics (per channel): Measurement range overflow/underflow; Limit value violation (min./max.); Wire break || Online simulation (per module): Diagnostics || Online simulation (per channel): Lock/Unlock; Simulation value: according to measurement range; Diagnostics || Measurement range (per channel): Parameterizable || Limiting values (per channel): Min./Max. || Linearization (per channel)): Linear; Type B; C; E; J; K; N; R; S; T || Cold junction compensation (per channel): Type: fixed temperature at current input; Compensation connector on the previous inpu; Temperature: value; Offset: value || Integration time (per channel): 2/ 4/ 8/ 16.7/ 20/ 30/ 60/ 120 ms || Substitute value (per channel): Value
- Protection
- Reverse voltage protection for ULS + Uo
- Resolution (over entire range)
- 0.1 °C or 0.01 mV
- Temperature coefficient
- ±0.05 K/K (type K)
- Sensor types
- Thermocouple K; Configurable: B, C, E, J, N, R, S, T; Voltage sensors: ± 36 mV, ± 72 mV, ± 145 mV, ± 290 mV
- Temperature range
- Type-dependent from −100 to +1,800 °C
- Measurement range
- Thermocouples: Type B: +200 … +1,820 °C; Type C: 0 … +2,320 °C; Type E: –250 … +1,000 °C; Type J: –210 … +1,200 °C; Type K: –210 … +1,370 °C; Type N: –210 … +1,300 °C; Type R: –50 … +1,768 °C; Type S: –50 … +1,768 °C; Type T: –210 … +400 °C; Voltage sensors: MB1: ±36 mV; MB2: ±72 mV; MB3: ±145 mV; MB4: ±290 mV
- Supply voltage (system and sensor)
- 24 VDC(-25 … +30 %); Logic and sensors (ULS)
- Current consumption (system and sensor)
- 40 mA
- Supply voltage (field)
- 24 VDC (-25 … +30 %); Actuators (UA), for transmission only
- Current consumption, field supply (module with no external load)
- 5 mA
- Isolation
- 500 V supply/system bus
- Indicators
- LED (F) red: Error status; LED (SB) green/red/orange: System bus status; LED (ULS, UA) green: Power supply status; LED (Ch1 … Ch4) yellow: Status AI 1 … AI 4; LED (Er1 … Er4) red: Error AI 1 … AI 4; Non-retentive displays
- Current carrying capacity (supply connections)
- 8 A
- Sampling repetition time
- Number of active channels x conversion time
- Integration time
- 2 … 120 ms
- Monotonicity without error codes
- Yes
- Conversion method (2)
- SigmaDelta
- Conversion time (2)
- Integration time x 3
- Max. measurement error (cold junction)
- ≤ ± 1 K
- Max. measurement error (without temperature compensation)
- ≤ ± 1 K over the entire measurement range (for type K)
- Maximum error over the full temperature range
- ± 3 K
Specifications
- Product Group Code
- 0015
Commercial Data
- Packaging type
- Bag
- Country of origin
- DE
- GTIN
- 4045454951108
- Customs tariff number
- 85389099990
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther