Part Number
787-2852
Tariff Code
85044082900
UPC
4055143295529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : DC-power supply
Class Code : EC002540
Version : 7
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Safety And Protection

Isolation voltage (pri.-sec.)
DC 4.242 kV
Protection class
II
Protection type
IP20; per EN 60529
Resistance to reverse feed
≤ DC 60 V
Pollution degree
2
Transient suppression (primary)
Varistor
Overvoltage protection; secondary
Internal protective circuit || ≤ 29 … 31 VDC (in the event of a fault)
Short-circuit-protected
Yes
Open-circuit-proof
Yes
Parallel operation
Yes, for 2 devices of the same type
Series operation
Yes, for 2 devices of the same type
MTBF
> 500,000 h (at 25 °C per IEC 61709)

Environmental Requirements

Ambient temperature (operation)
-25 … +70 °C (Nominal mounting position; −25 … +55 °C (in any mounting position))
Ambient temperature (storage)
-25 … +85 °C
Relative humidity
5 … 96 % (no condensation permissible)
Derating
-2 %/K (> 60 °C)

Connection Data

Number of jumper slots
4
Connection type 1
Input/output/signaling
Connection technology
Push-in CAGE CLAMP®
WAGO connector
picoMAX® 5.0
Solid conductor
0.2 … 2.5 mm² / 24 … 10 AWG
Fine-stranded conductor
0.2 … 2.5 mm² / 24 … 10 AWG
Strip length
9 … 10 mm / 0.35 … 0.39 inches

Signaling And Communication

Signaling
1 x LED DC OK (green) || 1 x Overload LED (red) || 1 x Active signal output DC OK (24 VDC; 20 mA)
Operation status indicator
Green LED (Uo > 21.5 V) || Red LED (overload)

Physical Data

Width
22.5 mm / 0.886 inches
Height from upper-edge of DIN-rail
107 mm / 4.213 inches
Depth
105 mm / 4.122 inches

Material Data

Fire load
1.417 MJ
Weight
200.000 g

Input

Phases
1
Nominal input voltage Ui nom
1 x AC 100 … 240 V
Input voltage range
1 x AC 85 … 264 V; DC 120 … 372 V
Nominal mains frequency range
47 … 63 Hz; 0 Hz
Input current Ii
≤ 0.28 A (240 VAC; nominal load); ≤ 0.49 A (100 VAC; nominal load)
Discharge current
≤ 1 mA
Inrush current
≤ 30 A
Power factor
≥ 0.6 (230 VAC; Nominal load; per EN 61000-3-2)
Power factor correction (PFC)
None
Mains failure hold-up time
≥ 20 ms (100 VAC)

Output

Nominal output voltage Uo nom
DC 24 V (SELV)
Default setting
DC 24 V
Nominal output current Io nom
1 A
Nominal output power
24 W
Deviation
≤ 2 %
Deviation, dynamic load change 10 … 90 %
≤ 1 %
Residual ripple
≤ 100 mV (peak-to-peak)
Current limitation
1.1 x Io nom (typ.)
Overload behavior
Constant current

Standards And Specifications

Conformity marking
CE
Standards/specifications
EN 61000-6-2 || EN 61000-6-3 || EN 60950-1 || DNV
Standards/specifications (pending)
UL 60950 || CULus 508 || ANSI/ISA 12.12.01 (Class I Div. 2) || ATEX/IEC Ex

Mechanical Data

Mounting type
DIN-35 rail

Specifications

Product Group Code
0006

Commercial Data

Packaging type
Box
Country of origin
DE
GTIN
4055143295529
Customs tariff number
85044083900

Efficiency/Power Losses

Power loss Pl
≤ 1 W; ≤ 4.3 W (230 VAC; nominal load)
Power loss (max.) Pl (max.)
5 W (100 VAC / 24 VDC; 1 A)
Efficiency (typ.)
86 % (230 VAC; nominal load); 84 % (110 VAC; nominal load)

<B>Circuit Protection</B>

Internal fuse
T 2 A / 250 VAC
Backup fusing (recommended)
Circuit breaker: 6 A, 10 A, 16 A; Tripping characteristic: B or C