Wago
879-3020
Energy meter (MID); for direct connection; 65A; 3x230/400V; 50Hz; Modbus® and M-Bus; 2 x S0 interface; 4PS
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
A total of 8 Parts In-Stock from 10 Distributors
Product Conditions:
Offer with manufacturer lead time
Ships in:On Request
Best price:
€165.90
Additional Information
- Part Number
- 879-3020
- UPC
- 4066966125412
- Tariff Code
- 90283019000
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Current transformer
- Class Code : EC002048
- Version : 7
Safety And Protection
- Dielectric strength
- 4 kV; 1 min
- Impulse withstand voltage (1.2/50 μs)
- 6 kV
- Pollution degree
- 2
- Protection type
- IP51 / IP20; IP51 (front side); IP20 (connection)
- Protection class
- II
Communication
- Communication
- Modbus® || M-Bus || Bluetooth®
- Interface
- RS-485 (2-wire); 2x S0 interfaces (configurable)
- Rate control input
- 230 VAC
- Indicators
- LCD with backlight
Signal Processing
- Measured variables (calculated)
- Active and reactive energy in supply and reference direction
- Measurement type (load profile)
- No
Configuration
- Configuration options
- Touch-sensitive controls || Configuration app via Bluetooth®
Environmental Requirements
- Ambient temperature (operation)
- -40 … +70 °C
- Relative humidity
- ≤ 75% (during storage ≤ 95 %)
Connection Data
- Connection type 1
- Voltage/current
- Connection technology
- Push-in CAGE CLAMP®
- WAGO connector
- WAGO 2616 Series
- Actuation type
- Lever
- Solid conductor
- 0.75 … 16 mm² / 18 … 4 AWG
- Fine-stranded conductor
- 0.75 … 25 mm² / 18 … 4 AWG
- Fine-stranded conductor; with insulated ferrule
- 0.75 … 16 mm²
- Fine-stranded conductor; with uninsulated ferrule
- 0.75 … 16 mm²
- Strip length
- 18 … 20 mm / 0.71 … 0.79 inches
- Connection type 2
- Communication/rate control input
- Connection technology 2
- Push-in CAGE CLAMP®
- WAGO connector 2
- WAGO 2604 Series
- Actuation type 2
- Lever
- Solid conductor 2
- 0.2 … 4 mm² / 24 … 12 AWG
- Fine-stranded conductor 2
- 0.2 … 4 mm² / 24 … 12 AWG
- Fine-stranded conductor; with insulated ferrule 2
- 0.25 … 2.5 mm²
- Fine-stranded conductor; with uninsulated ferrule 2
- 0.25 … 2.5 mm²
- Strip length 2
- 9 … 11 mm / 0.35 … 0.43 inches
Signaling And Communication
- Communication
- Modbus® || M-Bus || Bluetooth®
- Configuration options
- Touch-sensitive controls || Configuration app via Bluetooth®
Supply
- Power supply type
- Via measurement circuit
- Power consumption Pmax. (phase; active power)
- 2 W
- Power consumption Pmax. (phase; apparent power)
- 10 VA
Physical Data
- Width
- 72 mm / 2.835 inches
- Height
- 140 mm / 5.512 inches
- Depth
- 63 mm / 2.48 inches
- Note (dimensions)
- Height without cover: 92 mm
Measurement Error
- Accuracy class
- Class B (= 1 % error); Active energy per EN 50470-3
- Calibration validity period
- 8 years
Material Data
- Housing material
- PC 940A
- Fire load
- 0.000 MJ
- Weight
- 280.000 g
Input
- Input signal type
- Voltage || Current
- Network configuration
- Two-wire, three-wire and four-wire networks
- Nominal input voltage Ui nom
- 3 x AC 230 … 400 V
- Input voltage range
- ±20 %
- Reference current Iref
- 5 A
- Input current Ii
- ≤ 65 A
- Frequency range
- 45 … 60 Hz
Standards And Specifications
- Conformity marking
- CE
- Standards/specifications
- EN 50470-1/3 || MID-compliant
Mechanical Data
- Mounting type
- DIN-35 rail
Specifications
- Product Group Code
- 0029
Commercial Data
- Country of origin
- CN
- GTIN
- 4066966125412
- Customs tariff number
- 90283019000
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther