Tools & Accessories SolaHD

36 results

E500TH SolaHD, General Accessories
SolaHD

E500TH

SBE Series Encapsulated Copper Wound Transformers - PN

In-Stock

The SBE Series encapsulated copper wound transformers are designed for industrial applications, featuring epoxy encapsulation that safeguards the cores and coils from moisture, dirt, and other contaminants. This design enhances durability and reliability in demanding environments.With a primary voltage range that includes configurations such as 120 x 240 Volt, 220 x 440 Volt, and 240 x 480 Volt, these transformers support multiple secondary voltage outputs, including 24 Volt and 120 Volt. The transformers are available with a KVA rating from 50 to 1000, accommodating various power needs.Additional features include extra deep, molded terminal barriers that minimize the risk of electrical failures due to arcing or frayed lead wires. The rugged construction of the SBE design is ideal for industrial control applications, ensuring longevity and consistent performance.

Available in:
US
Quantity
  • Unknown
    2 pcs.
HTS6F9AS SolaHD, General Accessories
SolaHD

HTS6F9AS

Automation Transformers Non Ventilated 50 VA to 45 kVA - PN

On Request

These automation transformers are engineered for non-ventilated applications, offering power ratings from 50 VA to 45 kVA. Their encapsulated design ensures protection in hazardous locations as well as in harsh industrial environments. The rugged NEMA 3R enclosures guard against dust and moisture ingress, while providing enhanced shock and vibration resistance. UL Listed, these transformers meet the latest edition of the National Electrical Code for Class I, Division 2, Group A-D locations when installed in accordance with NEC 501.100(B). They are available in both single and three-phase configurations and utilize aluminum windings. With frequency options of 50 or 60 Hz, these transformers are suitable for a variety of industrial applications, ensuring reliable performance under demanding conditions.

Ask for a quote
HS19F1B SolaHD, General Accessories
SolaHD

HS19F1B

Buck-Boost Transformers - PN

On Request

Buck-Boost Transformers are engineered to offer a compact and energy-efficient solution for voltage adjustment. These transformers can increase or decrease voltage by a small margin, typically between 5 to 27 percent, making them ideal for applications where the voltage requirements differ from the available line voltage. They are particularly effective for powering control panels and landscape lighting, ensuring optimal performance and longevity of the connected equipment. These transformers come in various specifications, including a primary voltage of 120 x 240 Volts with secondary options of 12/24 Volts. They are available in both non-encapsulated and encapsulated designs, accommodating frequencies of either 50/60 Hz or 60 Hz. The non-encapsulated variants are rated at 0.05, 0.1, 0.15, and 0.25 kVA, while the encapsulated models range from 0.5 to 7.5 kVA. Additionally, configurations with a primary voltage of 240 x 480 Volts and secondary options of 24/48 Volts are also available. These transformers utilize aluminum windings and are designed for single-phase applications, providing reliable voltage modification for a variety of loads.

Available in:
CZ
FR
DE
IT
NL
PL
+4 suppliers
Ask for a quote
E150EW SolaHD, General Accessories
SolaHD

E150EW

SBE Series Encapsulated Copper Wound Transformers - PN

On Request

The SBE Series encapsulated copper wound transformers are specifically designed for industrial applications, featuring epoxy encapsulation that safeguards the cores and coils from moisture, dirt, and other contaminants. This construction ensures durability and reliability in challenging environments.These transformers support various primary voltage configurations, including 120 x 240 Volts and 220 x 440 Volts, with secondary outputs of 24 Volts, 110 Volts, and 120 Volts, operating at frequencies of 50/60 Hz. The transformers are available in a range of continuous VA ratings, from 50 to 1000 VA, accommodating diverse power requirements.Additionally, the transformers are equipped with extra deep, molded terminal barriers that minimize the risk of electrical failures caused by arcing or damaged lead wires. The use of copper windings contributes to their efficiency, while their steel mounting plate facilitates stable installation. With a temperature rise of +55°C, these transformers are well-suited for demanding industrial settings.

Available in:
US
Ask for a quote
E050JL SolaHD, General Accessories
SolaHD

E050JL

Encapsulated Copper Wound Transformer - PN

On Request

The encapsulated copper wound transformer, designated as PN E050JL, is designed for industrial control applications. It is epoxy encapsulated, providing protection against moisture, dirt, and various industrial contaminants. The transformer features extra deep, molded terminal barriers to minimize the risk of electrical failure due to arcing or frayed lead wires. Its rugged construction ensures reliable operation in demanding environments.With a versatile configuration, this transformer supports multiple primary voltages including 120 x 240, 220 x 440, and 240 x 480 Volts, and offers secondary voltage options of 24, 110, and 115 Volts. The product operates at both 50 and 60 Hz with continuous VA ratings available from 50 to 1000, catering to a range of load requirements. Additionally, the temperature rise is rated at +55°C, and it is equipped with copper windings mounted on a steel plate, making it suitable for various industrial applications.

Available in:
US
Ask for a quote
K4E2H45S SolaHD, General Accessories
SolaHD

K4E2H45S

K-Factor Ventilated Transformers - PN

On Request

The K-Factor Ventilated Transformers are engineered to accommodate harmonic currents generated by non-linear loads, preventing overheating and premature failure. This design aspect is critical as standard transformers may not withstand the added losses associated with such loads. The transformers incorporate a core and coil structure that effectively manages DC flux produced by triplen harmonics, ensuring stable operation. With a K-4 rating, these transformers operate with a 480 ∆ primary and a 208Y/120 secondary configuration, available in various capacities ranging from 15 kVA to 500 kVA. The windings are constructed from aluminum, contributing to their reliability in performance.This model operates at a frequency of 60 Hz and is configured for three-phase applications with a temperature rise rating of +150°C, which is essential for maintaining optimal operational conditions.

Ask for a quote
E250EWB SolaHD, General Accessories
SolaHD

E250EWB

Encapsulated Copper Wound Transformers - PN

On Request

The encapsulated copper wound transformers in the SBE Series are specifically designed for industrial control applications, providing multiple voltage configurations to suit various operational needs. With a primary voltage range including 120 x 240 Volt, 220 x 440 Volt, and 240 x 480 Volt among others, these transformers are capable of delivering secondary voltages of 24 Volt, 110 Volt, 115 Volt, and 120 Volt.These transformers feature epoxy encapsulation, offering enhanced protection for the cores and coils against moisture, dirt, and industrial contaminants. This construction reduces the risk of electrical failure due to arcing or frayed lead wires, thanks to the extra deep, molded terminal barriers. The SBE design, with a temperature rise rating of +55°C, is well-suited for demanding industrial environments, ensuring reliability and longevity.With KVA ratings available from 50 to 750, including continuous VA options, this series accommodates diverse power requirements. The windings are constructed of copper, mounted on a steel mounting plate, providing a robust solution for various applications.

Available in:
US
Ask for a quote
DT661H27S SolaHD, General Accessories
SolaHD

DT661H27S

Drive Isolation Transformers - PN

On Request

Drive Isolation Transformers facilitate SCR (Silicon Control Rectifier) variable speed motor drive systems by providing magnetic isolation between the incoming line and the motor drive. These transformers also adjust the voltage to align with the SCR Drive requirements. The standard configurations include a delta primary and a wye secondary, which are compatible with the typical power sources found in three-phase rectifier circuits. This model, designated as PN DT661H27S, supports various kVA ratings ranging from 7.5 to 440 kVA. It operates on multiple input voltage ranges of 460-575 Vac and features an output voltage range of 133-460 Vac. The transformers are designed for three-phase systems and can accommodate varying drive horsepower from 5 to 400 HP. With aluminum windings, the transformers are rated for a temperature rise of +150°C, ensuring durability in demanding applications.

Ask for a quote
HT5F15AS SolaHD, General Accessories
SolaHD

HT5F15AS

Automation Transformers Non Ventilated 50 VA to 45 kVA - PN

On Request

The Automation Transformers, designated as PN HT5F15AS, are designed for non-ventilated operation, serving a range from 50 VA to 45 kVA. These transformers are specifically constructed for deployment in hazardous locations and challenging industrial settings. Their encapsulation, combined with rugged NEMA 3R enclosures, ensures protection against dust and moisture while enhancing resistance to shock and vibration.These UL Listed transformers conform to the latest National Electrical Code standards for Class I, Division 2, Group A-D locations, contingent upon installation in accordance with NEC 501.100(B). The units are available in both single and three-phase configurations and support operational frequencies of 50 or 60 Hz. The windings are made of aluminum, contributing to their efficiency and durability.

Available in:
US
Ask for a quote
HZ1000 SolaHD, General Accessories
SolaHD

HZ1000

HZ Series Industrial Control Transformers - PN

On Request

The HZ Series industrial control transformers are specifically engineered for scenarios where external mounting outside the control panel is necessitated by thermal or economic constraints. This transformer features encapsulated copper windings tailored for industrial use. With a UL Class +180°C insulation system, it supports a temperature rise of +80°C when operating at full load.Standard configurations are UL Listed and NEMA Type 3R rated for rainproof applications, while custom options can be provided to meet UL Listed and NEMA Type 4, 4X, and 12 specifications. The transformers are available with various primary voltage options ranging from 220 to 575 volts and secondary voltage choices from 110 to 240 volts, designed for operation at 50/60 Hz.

Available in:
US
Ask for a quote
HSP1F1BS SolaHD, General Accessories
SolaHD

HSP1F1BS

Automation Transformers Non Ventilated 50 VA to 45 kVA - PN

On Request

These automation transformers are designed for non-ventilated applications with power ratings ranging from 50 VA to 45 kVA. They are encapsulated and constructed to operate effectively in hazardous locations and tough industrial settings. The encapsulation process, along with rugged NEMA 3R enclosures, provides essential protection against dust and moisture, enhancing durability and resistance to shock and vibration. These transformers are UL Listed and comply with the latest National Electrical Code (NEC) for Class I, Division 2, Group A-D locations, provided they are installed according to NEC 501.100(B). Operating at either 50 or 60 Hz and available in single or three-phase configurations, these transformers utilize aluminum windings which contribute to their reliability in demanding operational conditions.

Ask for a quote
E075EW SolaHD, General Accessories
SolaHD

E075EW

SBE Series Encapsulated Copper Wound Transformers - PN

On Request

The SBE Series encapsulated copper wound transformers offer a robust solution for industrial control applications. These transformers are epoxy encapsulated, ensuring that the cores and coils are shielded from moisture, dirt, and various industrial contaminants. The design incorporates extra deep, molded terminal barriers, significantly minimizing the risk of electrical failures caused by arcing or damaged lead wires.These transformers support a range of primary voltages including 120 x 240V, 220 x 440V, and 240 x 480V with corresponding secondary voltages of 24V, 110V, and 120V. They operate efficiently at both 50Hz and 60Hz, with continuous VA ratings spanning from 50 to 1000. Notably, the SBE Series is rated for a temperature rise of +55°C, and features copper windings mounted on a durable steel plate, making them particularly well-suited for demanding industrial environments.

Available in:
US
Ask for a quote
DT631H175S SolaHD, General Accessories
SolaHD

DT631H175S

Drive Isolation Transformers - PN

On Request

Drive Isolation Transformers facilitate the magnetic isolation of the incoming line from motor drives in SCR (Silicon Control Rectifier) variable speed applications. They are essential for matching the voltage requirements of the SCR drive. The typical configuration includes a delta primary with a wye secondary, aligning with the prevalent power sources used in three-phase rectifier circuits.This specific model operates with a primary voltage of 460 ∆ or 575 ∆, and secondary voltages of 266 or 133 Vac, depending on the configuration. The transformers are rated for a kVA range of 7.5 to 440 kVA and can accommodate drive horsepower from 5 to 400. The input voltage range spans 460-575 Vac, and the output voltage varies from 133 to 460 Vac. The design incorporates aluminum windings and is rated for a temperature rise of +150°C, ensuring reliable performance in demanding environments.

Available in:
US
Ask for a quote
F2F112S SolaHD, General Accessories
SolaHD

F2F112S

Automation Transformers, Floor Mount, Non-Ventilated 15 kVA to 150 kVA - PN

On Request

The automation transformers offered in this range are designed for floor mounting and feature a non-ventilated encapsulated construction. With power ratings varying from 15 kVA to 150 kVA, these transformers are suitable for use in Class I, Division 2/Zone 2 hazardous locations as well as in demanding industrial conditions. The UL Listed/NEMA Type 1, 2, 3R, 4, and 12 encapsulated enclosure ensures that these transformers are protected from dust and moisture, providing enhanced resistance to shock and vibration.These transformers comply with the latest National Electrical Code standards, ensuring reliability and safety in operation. The design includes options for aluminum or copper windings, with a frequency rating of 60 Hz and a three-phase configuration. Additionally, custom designs are available, including NEMA 4X stainless steel enclosures, low temperature copper wound options, and K-factor designs that cater to specific application needs.

Ask for a quote
E100D SolaHD, General Accessories
SolaHD

E100D

SBE Series Encapsulated Copper Wound Transformers - PN

On Request

The SBE Series encapsulated copper wound transformers provide reliable performance in industrial settings, featuring epoxy encapsulation that safeguards the cores and coils from moisture, dirt, and other contaminants. This design includes extra deep, molded terminal barriers to minimize the risk of electrical failures due to arcing or damaged lead wires.These transformers support multiple primary and secondary voltage configurations, including 120 x 240 Volt and 24 Volt, as well as 220 x 440 Volt with 110 Volt secondary options. They are rated for continuous VA ranging from 50 to 1000, accommodating various operational requirements. The windings are constructed from copper and mounted on a robust steel plate, ensuring durability and longevity.With a temperature rise of +55°C, these transformers are engineered for effective heat management, making them suitable for demanding industrial applications. The SBE Series is designed for 60 Hz and 50/60 Hz operations, providing versatility in different environments. For specifications, refer to Designation Code PN E100D.

Available in:
US
Ask for a quote
HZ7500A SolaHD, General Accessories
SolaHD

HZ7500A

HZ Series Industrial Control Transformers - PN

On Request

The HZ Series industrial control transformers are specifically designed for scenarios where mounting within the control panel is impractical due to cost or heat constraints. This particular transformer is encapsulated and constructed with copper windings, making it suitable for a range of industrial applications. The transformer is rated for a temperature rise of +80°C under full load, supported by a UL Class +180°C insulation system. Standard configurations are UL Listed and meet NEMA Type 3R specifications, ensuring rainproof performance. Additionally, custom versions are available that comply with UL Listed/NEMA Type 4, 4X, and 12 standards, providing flexibility in installation and environmental adaptability. The transformer supports various primary voltage options from 220 to 575 volts and secondary voltage configurations between 110 and 240 volts, accommodating diverse operational requirements.

Available in:
US
Ask for a quote
HS22F75A SolaHD, General Accessories
SolaHD

HS22F75A

Buck-Boost Transformers - PN

On Request

Buck-Boost Transformers offer a compact solution for adjusting voltage, providing an efficient and cost-effective method to raise or lower voltage by a small percentage. With a primary voltage of 120 x 240 Volts and secondary options of 12/24 Volts, these transformers are well-suited for applications that require specific voltage levels differing from the standard line voltage. The encapsulated design operates at 60 Hz and is available in various kVA ratings, including 0.5, 0.75, 1, 1.5, 2, 3, 5, and 7.5 kVA, ensuring compatibility with various loads. Additionally, the non-encapsulated versions cater to both 50 and 60 Hz at 0.05, 0.1, 0.15, and 0.25 kVA. Proper selection of a buck-boost transformer can enhance the performance and longevity of connected equipment. These transformers feature single-phase aluminum windings, ensuring reliable operation across multiple configurations, including 240 x 480 Volt primary with 24/48 Volt secondary options.

Ask for a quote
K20E2H150S SolaHD, General Accessories
SolaHD

K20E2H150S

K-Factor Ventilated Transformers - PN

On Request

K-Factor Transformers are specifically engineered to accommodate harmonic currents generated by non-linear loads, ensuring the insulation system's temperature rating is not exceeded. This model incorporates a core and coil design that effectively manages the DC flux resulting from triplen harmonics, which can lead to overheating in standard transformers.The transformer operates with a primary voltage of 480 ∆ and a secondary voltage of 208Y/120, providing reliable performance across multiple kVA ratings, including 15, 30, 45, 75, 112.5, 150, 225, 300, and 500 kVA for Group A with a K-4 rating, Group B with a K-13 rating, and Group C with a K-20 rating. Designed for a three-phase system and rated at 60 Hz, this unit incorporates aluminum windings and maintains a temperature rise of +150°C.

Available in:
US
Ask for a quote
T2000 SolaHD, General Accessories
SolaHD

T2000

SMT Series Aluminum Wound Open Style Transformers - PN

On Request

The SMT Series aluminum wound open style transformers are available in ratings from 1 KVA to 5 KVA. These transformers are designed with varnished coils and operate under a class +180°C insulation system, achieving a temperature rise of +115°C at full load. The primary voltage options range from 220 to 480 volts, with secondary voltage configurations of 110, 115, or 120 volts depending on the application. Compliance with NEMA specifications ensures reliable electrical performance and regulation, offering significant cost advantages. The transformers are equipped with mounting feet for versatile installation.

Available in:
US
Ask for a quote
K4E2H500S SolaHD, General Accessories
SolaHD

K4E2H500S

K-Factor Ventilated Transformers - PN

On Request

K-Factor Ventilated Transformers are engineered to accommodate the harmonic currents generated by non-linear loads, ensuring that the temperature rating of the insulation system is not exceeded. This transformer model, designated as K-Factor Group A with a K-4 rating, operates with a primary voltage of 480 ∆ and a secondary voltage of 208Y/120. It is available in kVA ratings of 15, 30, 45, 75, 112.5, 150, 225, 300, and 500. The design effectively addresses the increase in stray losses that can lead to overheating and premature failure of standard transformers when subjected to non-linear loads. With a robust core and coil configuration, these transformers manage the DC flux induced by triplen harmonics, enhancing reliability. This model features a three-phase configuration, operates at a frequency of 60 Hz, and includes aluminum windings. It also has a temperature rise rating of +150°C, which is critical for applications demanding high performance under varying electrical loads.

Available in:
US
Ask for a quote