Need more information?

Call us at:+48 17 778 34 19

ABB 1SAM350000R1011MS132-16 Manual Motor Starter 10 ... 16 A

1 / 3
1SAM350000R1011 ABB, PLCs
Reference Image - Not actual item!
1SAM350000R1011 ABB, PLCs
Reference Image - Not actual item!
1SAM350000R1011 ABB, PLCs
1SAM350000R1011 ABB, PLCs
1SAM350000R1011 ABB, PLCs
1SAM350000R1011 ABB, PLCs

Offer Description

The MS132-16 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 16.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.MS132-16 Manual Motor Starter 10 16 A ABB

Product Description

The MS132-16 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 16.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.

Product Details

Brand
ABB
Country of Origin
DE
Part Number
1SAM350000R1011
Tariff Code
85362010
EAN
4013614400117
UNSPSC
39121521
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Motor protection circuit-breaker
Class Code : EC000074
Version : 7
$152.91
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 18-07-2025
Warranty:
12 months
Estimated Delivery:
25-30 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
45 mm
Product Net Height
97.8 mm
Product Net Depth / Length
86.55 mm
Product Net Weight
0.31 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 100 kA(250 V DC) 3 Poles in Series 10 kA(400 V AC) 100 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)
240 A
Setting Range
10 ... 16 A
Rated Operational Power AC-3 (Pe)
(400 V) Three Phase 7.5 kW
Rated Operational Power AC-3e (Pe)
(400 V) Three Phase 7.5 kW
Rated Operational Voltage
Main Circuit 690 V ACMain Circuit 250 V DC
Rated Operational Current (Ie)
16 A
Rated Operational Current AC-3 (Ie)
16 A
Rated Operational Current AC-3e (Ie)
16 A
Rated Operational Current DC-5 (Ie)
16 A
Rated Frequency (f)
Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 1.1 ... 2.8 W
Number of Poles
3
Conventional Free-air Thermal Current (Ith)
Main Circuit 16 A
Degree of Protection
Housing IP20Main Circuit Terminals IP10
Pollution Degree
3
Electrical Durability
50000 cycle
Mechanical Durability
100000 cycle
Terminal Type
Screw Terminals
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²Flexible 1/2x 1 ... 2.5 mm²Flexible 1/2x 2.5 ... 6 mm²Rigid 1/2x 1 ... 2.5 mm²Rigid 1/2x 2.5 ... 6 mm²
Tightening Torque
Main Circuit 2 N·m
Wire Stripping Length
Main Circuit 10 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance
Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator Type
Rotary Handle
Contact Position Indication
ON / OFF / TRIP
Standards
IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1
Remarks
UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Classifications

Object Classification Code
F
ETIM 4
EC000074 - Motor protective circuit-breaker
ETIM 5
EC000074 - Motor protective circuit-breaker
EClass
V11.0 : 27370401
IDEA Granular Category Code (IGCC)
4731 >> Manual Starters
E-Number (Finland)
3705995
E-Number (Sweden)
3112127

Environmental

Ambient Air Temperature
Around the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6
5g / 3 ... 150 Hz
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Technical UL/CSA

Short-Circuit Current Rating (SCCR)
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Horsepower Rating UL/CSA
(200 V AC) Three Phase 3 Hp(208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 5 Hp(440 ... 480 V AC) Three Phase 10 Hp(550 ... 600 V AC) Three Phase 10 Hp
Full Load Amps Motor Use
(200 V AC) Three Phase 11 A(208 V AC) Three Phase 10.6 A(220 ... 240 V AC) Three Phase 15.2 A(440 ... 480 V AC) Three Phase 14 A(550 ... 600 V AC) Three Phase 11 A
Locked Rotor Amps
(200 V AC) Three Phase 73.6 A(208 V AC) Three Phase 71 A(220 ... 240 V AC) Three Phase 92 A(440 ... 480 V AC) Three Phase 81 A(550 ... 600 V AC) Three Phase 64.8 A
General Use Rating UL/CSA
(600 V AC) 16 A
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 16-8 AWGStranded 1/2x 16-8 AWG
Tightening Torque UL/CSA
Main Circuit 18 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85362010

Documents

Data Sheet

Datasheet for ABB 1SAM350000R1011, including specifications and features.

Download Data Sheet

Related products

1SDA023393R1 ABB, Circuit Breakers
1SDA023393R1
ABB
KIT EF T6 800 - S6 800 4pcs
1SDA044751R1 ABB, Other
1SDA044751R1
ABB
CONNECT.+CABLES FOR AUX F L=2MT S7
1SDA054286R1 ABB, Other
1SDA054286R1
ABB
T4L 250 TMA 250-2500 4p F F InN=100%In
1SDA054659R1 ABB, Other
1SDA054659R1
ABB
TMA 250-1250...2500 T4 3p
1SDA064588R1 ABB, Other
1SDA064588R1
ABB
E2B 1600 PR122/DC In=1600A 4p F VR
1SDA072295R1 ABB, PLCs
1SDA072295R1
ABB
E2.2H 1000 Ekip Touch LSI 3p WMP
1SDA072898R1 ABB, Circuit Breakers
1SDA072898R1
ABB
E2.2H 800 Ekip Hi-Touch LSI 4p WMP
1SDA073827R1 ABB, Other
1SDA073827R1
ABB
KLP-S Pos.lock N.20009 E1.2-XT7/M 1key
1SDA073834R1 ABB, Other
1SDA073834R1
ABB
KLP-A Pos.lockRonProfKirk E1.2-XT7/M1key
1SDA073892R1 ABB, Other
1SDA073892R1
ABB
Lever interlock E6.2 4p
1SL0262A00 ABB, PLCs
1SL0262A00
ABB
GMP4B IP66 Insulating switchboards accessories
1SL1923A00 ABB, Distribution boards
1SL1923A00
ABB
1SLM006500A1923 Metal base plate 2x18M Mistral65 ; 1SLM006500A1923
1SVR730831R1400 ABB, Relays
1SVR730831R1400
ABB
CM-ESS.2S is a voltage monitoring relay for AC/DC systems (3-600V). It offers over/undervoltage detection, adjustable hysteresis and tripping delay, with 2 c/o outputs.
EM2005 ABB, Cables
EM2005
ABB
IS2-EM2005 Control and Automation Board
GD4002 ABB, Control Cabinets
GD4002
ABB
K-GD4002 Main Distribution Board
KO2281 ABB, Control Cabinets
KO2281
ABB
K-KO2281 Main Distribution Board
LF2050 ABB, Control Cabinets
LF2050
ABB
K-LF2050 Main Distribution Board
SM1262 ABB, Distribution boards
SM1262
ABB
M-SM1262 Cabinet, Rows: 3, 1200 mm x 600 mm x 200 mm, Grounded (Class I), IP65