Need more information?

Call us at:+48 17 778 34 19

ABB 1SAM360000R1007MO132-2.5 Manual Motor Starter Magnetic Only 2.5 A

1 / 3
1SAM360000R1007 ABB, Motors
Reference Image - Not actual item!
1SAM360000R1007 ABB, Motors
Reference Image - Not actual item!
1SAM360000R1007 ABB, Motors
1SAM360000R1007 ABB, Motors
1SAM360000R1007 ABB, Motors
1SAM360000R1007 ABB, Motors

Offer Description

The MO132-2.5 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 2.50 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.MO132-2.5 Manual Motor Starter Magnetic Only 2.5 A ABB 1SAM360000R1007

Product Description

The MO132-2.5 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 2.50 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.

Product Details

Brand
ABB
Country of Origin
DE
Part Number
1SAM360000R1007
Tariff Code
85362010
EAN
4013614400223
UPC
40136144002230
UNSPSC
39121521
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Motor protection circuit-breaker
Class Code : EC000074
Version : 7
$148.80
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 16-07-2025
Warranty:
12 months
Estimated Delivery:
24-29 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
45 mm
Product Net Height
90 mm
Product Net Depth / Length
86.75 mm
Product Net Weight
0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 100 kA(500 V AC) 100 kA(690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 100 kA(500 V AC) 100 kA(690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)
31.3 A
Setting Range
None
Rated Operational Power AC-3 (Pe)
(400 V) Three Phase 0.75 kW
Rated Operational Power AC-3e (Pe)
(400 V) Three Phase 0.75 kW
Rated Operational Voltage
Main Circuit 690 V AC
Rated Operational Current (Ie)
2.5 A
Rated Operational Current AC-3 (Ie)
2.5 A
Rated Operational Current AC-3e (Ie)
2.5 A
Rated Frequency (f)
Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 1.7 W
Number of Poles
3
Conventional Free-air Thermal Current (Ith)
Main Circuit 2.5 A
Degree of Protection
Housing IP20Main Circuit Terminals IP10
Pollution Degree
3
Electrical Durability
50000 cycle
Mechanical Durability
100000 cycle
Terminal Type
Screw Terminals
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
Tightening Torque
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Main Circuit 9 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance
Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator Type
Rotary Handle
Contact Position Indication
ON / OFF / TRIP
Standards
IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1
Remarks
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used

Classifications

Object Classification Code
F
ETIM 4
EC000074 - Motor protective circuit-breaker
ETIM 5
EC000074 - Motor protective circuit-breaker
EClass
V11.0 : 27370401
IDEA Granular Category Code (IGCC)
4731 >> Manual Starters
E-Number (Finland)
3705885
E-Number (Sweden)
3110035

Environmental

Ambient Air Temperature
Around the Enclosure 0 ... +40 °COperation -25 ... +60 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation
No
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6
5g / 3 ... 150 Hz
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Technical UL/CSA

Short-Circuit Current Rating (SCCR)
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Horsepower Rating UL/CSA
(200 V AC) Three Phase 0.5 Hp(208 V AC) Three Phase 0.5 Hp(220 ... 240 V AC) Three Phase 0.5 Hp(440 ... 480 V AC) Three Phase 1 Hp(550 ... 600 V AC) Three Phase 1.5 Hp
Full Load Amps Motor Use
(200 V AC) Three Phase 2.5 A(208 V AC) Three Phase 2.5 A(220 ... 240 V AC) Three Phase 2.5 A(440 ... 480 V AC) Three Phase 2.5 A(550 ... 600 V AC) Three Phase 2.5 A
Locked Rotor Amps
(200 V AC) Three Phase 15 A(208 V AC) Three Phase 15 A(220 ... 240 V AC) Three Phase 15 A(440 ... 480 V AC) Three Phase 15 A(550 ... 600 V AC) Three Phase 15 A
General Use Rating UL/CSA
(600 V AC) 2.5 A
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 16-12 AWGStranded 1/2x 16-12 AWG
Tightening Torque UL/CSA
Main Circuit 10 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85362010

Related products

ED2212SK ABB, Control Cabinets
ED2212SK
ABB
IS2-ED2212SK Control and Automation Board
MP1-11R ABB, Other
MP1-11R
ABB
PB MOM RED FLUSH ILL
SN201-S ABB, Distribution boards
SN201-S
ABB
SN201-S Signal contact
1SAJ924007R0001 ABB, Other
1SAJ924007R0001
ABB
PROFIBUS DP Termination Unit
1SDA047825R1 ABB, Other
1SDA047825R1
ABB
Isolating jaw-type contact Kit E3 8pcs
1SDA072473R1 ABB, Circuit Breakers
1SDA072473R1
ABB
E4.2V 2500 Ekip Dip LSIG 3p WMP
1SDA073133R1 ABB, Other
1SDA073133R1
ABB
E4.2S 3200 Ekip Dip LSIG 4p WMP
1SDA073890R1 ABB, Other
1SDA073890R1
ABB
Lever interlock E4.2
1SVR405618R4400 ABB, Relays
1SVR405618R4400
ABB
CR-M012DC4LDG PLUGGABLE INTERFACE R
EH3083K ABB, Control Cabinets
EH3083K
ABB
IS2-EH3083K Control and Automation Board
LF1626 ABB, Control Cabinets
LF1626
ABB
K-LF1626 Main Distribution Board
NCG-1002LG ABB, Other
NCG-1002LG
ABB
NYLON CG 1 NPT 18.0-25.0MM LGRY
PO1431 ABB, Control Cabinets
PO1431
ABB
L-PO1431 Cabinet, 1400 mm x 300 mm x 1.5 mm, IP43
SK8060 ABB, Control Cabinets
SK8060
ABB
K-SK8060 Main Distribution Board