ABB 1SBL177001R1101AF16-30-01-11 24-60V50/60HZ 20-60VDC Contactor

1 / 1
1SBL177001R1101 ABB, Contactors
Reference Image - Not actual item!

Offer Description

3 POLE CONTACTOR, 3 NORMALLY OPEN CONTACTS, 7.5KW, 20-60 VDC, 1 NC AUXILIARY, 6 KV IMPULSE

Product Description

The AF16-30-01-11 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 7.5 kW / 400 V AC (AC-3) or 10 hp / 480 V UL and switching power circuits up to 30 A (AC-1) or 30 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Product Details

Brand
ABB
Country of Origin
FR
Part Number
1SBL177001R1101
Tariff Code
85364900
EAN
3471523110717
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7
$58.45
excl. tax
Supplier Price
€53.62
Payment methods:

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
23 pcs.
In-Stock
Updated at: 19-05-2025
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Return & Refund Policies

Secure Payment Process

Dimensions

Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.27 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 VMain Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 Aacc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 30 A(690 V) 60 °C 30 A(690 V) 70 °C 26 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 18 A(440 V) 60 °C 18 A(500 V) 60 °C 15 A(690 V) 60 °C 10.5 A(380 / 400 V) 60 °C 18 A(220 / 230 / 240 V) 60 °C 18 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 18 A(440 V) 60 °C 18 A(500 V) 60 °C 15 A(690 V) 60 °C 10.5 A(380 / 400 V) 60 °C 18 A(220 / 230 / 240 V) 60 °C 18 A
Rated Operational Power AC-3 (Pe)
(400 V) 7.5 kW(415 V) 9 kW(440 V) 9 kW(500 V) 9 kW(690 V) 9 kW(380 / 400 V) 7.5 kW(220 / 230 / 240 V) 4 kW
Rated Operational Power AC-3e (Pe)
(415 V) 9 kW(440 V) 9 kW(500 V) 9 kW(690 V) 9 kW(380 / 400 V) 7.5 kW(220 / 230 / 240 V) 4 kW
Rated Operational Current AC-15 (Ie)
(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 Afor 0.1 s 140 Afor 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 20 A(110 V) 1-Pole, 60 °C 20 A(110 V) 1-Pole, 70 °C 20 A(110 V) 2 Poles in Series, 40 °C 30 A(110 V) 2 Poles in Series, 60 °C 30 A(110 V) 2 Poles in Series, 70 °C 26 A(110 V) 3 Poles in Series, 40 °C 30 A(110 V) 3 Poles in Series, 60 °C 30 A(110 V) 3 Poles in Series, 70 °C 26 A(220 V) 2 Poles in Series, 40 °C 20 A(220 V) 2 Poles in Series, 60 °C 20 A(220 V) 2 Poles in Series, 70 °C 20 A(220 V) 3 Poles in Series, 40 °C 30 A(220 V) 3 Poles in Series, 60 °C 30 A(220 V) 3 Poles in Series, 70 °C 26 A(72 V) 1-Pole, 40 °C 30 A(72 V) 1-Pole, 60 °C 30 A(72 V) 1-Pole, 70 °C 26 A(72 V) 2 Poles in Series, 40 °C 30 A(72 V) 2 Poles in Series, 60 °C 30 A(72 V) 2 Poles in Series, 70 °C 26 A(72 V) 3 Poles in Series, 40 °C 30 A(72 V) 3 Poles in Series, 60 °C 30 A(72 V) 3 Poles in Series, 70 °C 26 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 8 A(110 V) 1-Pole, 60 °C 8 A(110 V) 1-Pole, 70 °C 8 A(110 V) 2 Poles in Series, 40 °C 30 A(110 V) 2 Poles in Series, 60 °C 30 A(110 V) 2 Poles in Series, 70 °C 26 A(110 V) 3 Poles in Series, 40 °C 30 A(110 V) 3 Poles in Series, 60 °C 30 A(110 V) 3 Poles in Series, 70 °C 26 A(220 V) 2 Poles in Series, 40 °C 8 A(220 V) 2 Poles in Series, 60 °C 8 A(220 V) 2 Poles in Series, 70 °C 8 A(220 V) 3 Poles in Series, 40 °C 30 A(220 V) 3 Poles in Series, 60 °C 30 A(220 V) 3 Poles in Series, 70 °C 26 A(72 V) 1-Pole, 40 °C 30 A(72 V) 1-Pole, 60 °C 30 A(72 V) 1-Pole, 70 °C 26 A(72 V) 2 Poles in Series, 40 °C 30 A(72 V) 2 Poles in Series, 60 °C 30 A(72 V) 2 Poles in Series, 70 °C 26 A(72 V) 3 Poles in Series, 40 °C 30 A(72 V) 3 Poles in Series, 60 °C 30 A(72 V) 3 Poles in Series, 70 °C 26 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 4 A(110 V) 1-Pole, 60 °C 4 A(110 V) 1-Pole, 70 °C 4 A(110 V) 2 Poles in Series, 40 °C 20 A(110 V) 2 Poles in Series, 60 °C 20 A(110 V) 2 Poles in Series, 70 °C 20 A(110 V) 3 Poles in Series, 40 °C 30 A(110 V) 3 Poles in Series, 60 °C 30 A(110 V) 3 Poles in Series, 70 °C 26 A(220 V) 2 Poles in Series, 40 °C 4 A(220 V) 2 Poles in Series, 60 °C 4 A(220 V) 2 Poles in Series, 70 °C 4 A(220 V) 3 Poles in Series, 40 °C 16 A(220 V) 3 Poles in Series, 60 °C 16 A(220 V) 3 Poles in Series, 70 °C 16 A(72 V) 1-Pole, 40 °C 16 A(72 V) 1-Pole, 60 °C 16 A(72 V) 1-Pole, 70 °C 16 A(72 V) 2 Poles in Series, 40 °C 30 A(72 V) 2 Poles in Series, 60 °C 30 A(72 V) 2 Poles in Series, 70 °C 26 A(72 V) 3 Poles in Series, 40 °C 30 A(72 V) 3 Poles in Series, 60 °C 30 A(72 V) 3 Poles in Series, 70 °C 26 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 Vacc. to IEC 60947-5-1 690 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V60 Hz 24 ... 60 VDC Operation 20 ... 60 V
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm²Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Rigid Solid 1/2x 1 ... 4 mm²Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mmControl Circuit 10 mmMain Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type
Screw Terminals

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3705805
E-Number (Sweden)
3211342

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 4 g closed position / 2 g open position
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 gOpen, Shock Direction: B1 5 gShock Direction: A 30 gShock Direction: B2 15 gShock Direction: C1 25 gShock Direction: C2 25 g
RoHS Status
Following EU Directive 2011/65/EU

Technical UL/CSA

Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1-1/2 hp(200 ... 208 V AC) Three Phase 5 hp(220 ... 240 V AC) Three Phase 5 hp(240 V AC) Single Phase 3 hp(440 ... 480 V AC) Three Phase 10 hp(550 ... 600 V AC) Three Phase 15 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWGRigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lbControl Circuit 11 in·lbMain Circuit 13 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900

Related products

1SNA031805R1200 ABB, Other
1SNA031805R1200
ABB
BNMS-T230VAC-1 - Optocoupler plug
1SNA020839R2400 ABB, Other
1SNA020839R2400
ABB
BFMHE-10/16-2E - Connecting Interface
1SNA020847R2400 ABB, Other
1SNA020847R2400
ABB
BFMSUBD-9F-2E - Connecting Interface
CE3T-10R-11 ABB, Other
CE3T-10R-11
ABB
30MM TW-REL RED 1 NO/1NC
1SDA060268R1 ABB, Other
1SDA060268R1
ABB
T6N 800 PR221DS-LS/I In=800 3p F F
1SDA072412R1 ABB, PLCs
1SDA072412R1
ABB
E2.2N 2500 Ekip Dip LSI 3p WMP
EE1880K ABB, Control Cabinets
EE1880K
ABB
IS2-EE1880K Control and Automation Board
1SDA072266R1 ABB, PLCs
1SDA072266R1
ABB
E2.2H 800 Ekip Touch LSIG 3p WMP
1SDA071004R1 ABB, Circuit Breakers
1SDA071004R1
ABB
E2.2S 1600 Ekip Touch LI 3p F HR
1SDA071779R1 ABB, Circuit Breakers
1SDA071779R1
ABB
E4.2N 3200 Ekip Hi-Touch LSIG 4p F HR
1SDA071894R1 ABB, Circuit Breakers
1SDA071894R1
ABB
E6.2H 5000 Ekip Touch LI 4p F HR
1SDA073279R1 ABB, Other
1SDA073279R1
ABB
E6.2H 6300 Ekip Hi-Touch LSIG 4p WMP
1SDA073341R1 ABB, Other
1SDA073341R1
ABB
E6.2V/f 5000 Ekip Dip LI 4p WMP
1SDA063094R1 ABB, PLCs
1SDA063094R1
ABB
LTC T7-T7M-X1 F 4p TERM.COVERS LOW 2pcs