The softstarter PSTX210-600-70 has a rated maximum operational current of 210 A with an operating voltage span from 208600 V AC. The rated control voltage is between 100250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional

Product Description

The softstarter PSTX210-600-70 has a rated maximum operational current of 210 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional ANYBUS modules with every major protocol such as for example Profinet, Profibus, Modbus TCP, Ethernet IP and others. Another way to communicate with PSTX is to use an external adaptor and a Fieldbus plug. PSTX is the complete alternative for any motor starting application. It’s suitable for medium to large-sized three-phase motors with nominal currents from 30...1250 A inline connection or 52...2160 A inside delta connection. Typical applications are, for example, pumps, fans, compressors, and conveyors.

Product Details

Brand
ABB
Part Number
1SFA898112R7000
EAN
39121521
UNSPSC
39121521
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Soft starter
Class Code : EC000640
Version : 7
$4,501.75
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 18-07-2025
Warranty:
12 months
Estimated Delivery:
25-30 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
258 mm
Product Net Height
470 mm
Product Net Depth / Length
279 mm
Product Net Weight
13.3 kg

Technical

Rated Operational Voltage
208 ... 600 V AC
Rated Control Supply Voltage (Us)
100 ... 250 V AC
Rated Control Circuit Voltage (Uc)
24 V DC
Rated Frequency (f)
50/60 HzMain Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)
(230 V) 59 kW(400 V) 110 kW(500 V) 132 kW
Rated Operational Current - In-Line Connection (Ie)
210 A
Rated Operational Power - Inside Delta Connection
at 230 V 102 kWat 400 V 184 kWat 500 V 250 kW
Rated Operational Current - Inside Delta Connection
360 A
Service Factor Percentage
100 %
Overload Protection
Built-in electronic overload protection
Integrated Electronic Overload
Yes
Adjustable Rated Motor Current Ie
30 ... 100 %
Starting Capacity at Maximum Rated Current Ie
4xIe for 10s
Ramp Time
1 ... 120 second [unit of time]
Initial Voltage During Start
10 ... 99 %
Step Down Voltage Special Ramp
100 ... 10 %
Current Limit Function
1.5 ... 7.5 xle
Switch for Inside Delta Connection
Yes
Run Signal Relay
Yes
By-pass Signal Relay
Yes
Fault Signal Relay
Yes
Overload Signal Relay
Yes
Analog Outputs
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED)
Green
Signal Indication Running R (LED)
Green
Signal Indication Protection (LED)
Yellow
Signal Indication Fault (LED)
Red
Communication
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection
IP00
Terminal Type
Main Circuit: Bars
Connecting Capacity Main Circuit
Hole Diameter 10.2 mm
Connecting Capacity Control Circuit
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit
Rigid 1 x 2.5 mm²
Tightening Torque
Main Circuit 25 N·m
Product Main Type
PSTX210
Function
Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logFull voltage startJog with slow speed, forward and reverseKeypad passwordKick startLimp mode with two-phase motor control if one set of thyristors is shortedMotor heatingPre-start functionPump cleaningReal time clockSequence startSoft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampStand still brakeStart reverse (external contactors)Thyristor runtime measurementTorque limitVoltage sags detection
Protection Function
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Classifications

Object Classification Code
Q
ETIM 9
EC000640 - Soft starter
EClass
V11.0 : 27370907
IDEA Granular Category Code (IGCC)
4740 >> Soft starter

Environmental

Ambient Air Temperature
Operation -25 ... +60 °CStorage -40 ... +70 °C
Degree of Protection
IP00
RoHS Status
Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Tightening Torque UL/CSA
Main Circuit 221.3

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85371091

Related products

05093 ABB, Cables
05093
ABB
WIRING DUCT PVC 120X80 8/12
1SDA014185R1 ABB, Other
1SDA014185R1
ABB
UVR 220/250VDC S6-S7
1SDA054749R1 ABB, Circuit Breakers
1SDA054749R1
ABB
T5 400 P FP 3p EF
1SDA066660R1 ABB, PLCs
1SDA066660R1
ABB
LTC XT3 3p TERMINAL COVERS LOW 2pcs
1SDA072041R1 ABB, Circuit Breakers
1SDA072041R1
ABB
E1.2N 250 Ekip Dip LI 3p WMP
1SDA072435R1 ABB, Other
1SDA072435R1
ABB
E2.2H 2500 Ekip Touch LSI 3p WMP
1SDA073409R1 ABB, Other
1SDA073409R1
ABB
E2.2N/MS 1600 3p F HR
1SDA073553R1 ABB, Other
1SDA073553R1
ABB
E6.2H/f/MS 4000 4p WMP
5354SST6 ABB, Other
5354SST6
ABB
1 Inch Liquidtight Fitting for Flexible Metallic Conduit, 90 Degree, UL/CSA Listed, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 3.32 Inches/84.33mm, Width 1.87 Inches/47.50mm, Height 2.95 Inches/74.93mm, Temperature Range 0 to 105 Degrees C, 316 Stainless Steel with Duraplated Ground Cone
EA1602 ABB, Control Cabinets
EA1602
ABB
IS2-EA1602 Control and Automation Board
EA2101 ABB, Other
EA2101
ABB
IS2-EA2101 Control and Automation Board
EN2105K ABB, Control Cabinets
EN2105K
ABB
IS2-EN2105K Control and Automation Board
NCG-M631LG ABB, Other
NCG-M631LG
ABB
NYLON CG M63X1.5 29.0-35.0MM LGRY
PF4810 ABB, Control Cabinets
PF4810
ABB
K-PF4810 Main Distribution Board, 71 mm x 381 mm x 650 mm
RF2040 ABB, Control Cabinets
RF2040
ABB
K-RF2040 Main Distribution Board