Need more information?
Call us at:+48 17 778 34 19
ABB 1SFL467002R1411AF146-30-11B-14 Contactor
1 / 1
Offer Description
CONTACTOR BAR CONNECTION, 3 POLE, 75KW AC3, COIL 250-500V50/60HZ 250-500VDC NO+NC AUX
Product Description
The AF146-30-11B-14 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Product Details
- Brand
- ABB
- Country of Origin
- SE
- Part Number
- 1SFL467002R1411
- Tariff Code
- 85364900
- EAN
- 7320500478424
- UNSPSC
- 39121529
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Power contactor, AC switching
- Class Code : EC000066
- Version : 7
≈
$543.88
excl. taxSupplier Price
€498.97
Payment methods:
Offer details
- Best offer from:
Trusted Automa.Net Supplier
- Availability:
- 2 pcs.In-StockUpdated at: 19-05-2025
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing
Are you a Supplier?
Join 650 suppliers, sell to 3500+ verified buyers.
Policies and Information
Return & Refund Policies
14 days for return
Secure Payment Process
Dimensions
- Product Net Width
- 90 mm
- Product Net Depth / Length
- 126 mm
- Product Net Height
- 150 mm
- Product Net Weight
- 1.3 kg
Technical
- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 1
- Number of Auxiliary Contacts NC
- 1
- Rated Operational Voltage
- Main Circuit 1000 V
- Rated Frequency (f)
- Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 225 A
- Rated Operational Current AC-1 (Ie)
- (1000 V) 40 °C 225 A(1000 V) 55 °C 200 A(1000 V) 60 °C 200 A(1000 V) 70 °C 175 A(690 V) 40 °C 225 A(690 V) 55 °C 200 A(690 V) 60 °C 200 A(690 V) 70 °C 175 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 55 °C 146 A(440 V) 55 °C 146 A(500 V) 55 °C 130 A(690 V) 55 °C 93 A(1000 V) 55 °C 60 A(380 / 400 V) 55 °C 146 A(220 / 230 / 240 V) 55 °C 146
- Rated Operational Current AC-3e (Ie)
- (415 V) 60 °C 146 A(440 V) 60 °C 146 A(500 V) 60 °C 130 A(690 V) 60 °C 93 A(1000 V) 60 °C 54 A(380 / 400 V) 60 °C 146 A(220 / 230 / 240 V) 60 °C 146 A
- Rated Operational Power AC-3 (Pe)
- (415 V) 75 kW(440 V) 90 kW(500 V) 90 kW(690 V) 90 kW(1000 V) 75 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW
- Rated Operational Power AC-3e (Pe)
- (415 V) 75 kW(440 V) 90 kW(500 V) 90 kW(690 V) 90 kW(1000 V) 75 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW
- Rated Breaking Capacity AC-3
- 8 x Ie AC-3
- Rated Breaking Capacity AC-3e
- 8.5 x Ie AC-3e
- Rated Making Capacity AC-3
- 10 x Ie AC-3
- Rated Making Capacity AC-3e
- 12 x Ie AC-3e
- Short-Circuit Protective Devices
- gG Type Fuses 315 A
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
- Maximum Electrical Switching Frequency
- (AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- Main Circuit 8 kV
- Mechanical Durability
- 5 million
- Maximum Mechanical Switching Frequency
- 300 cycles per hour
- Coil Operating Limits
- (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
- Rated Control Circuit Voltage (Uc)
- 50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V
- Coil Consumption
- Average Pull-in Value 50 Hz 260 V·AAverage Pull-in Value 60 Hz 260 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·AHolding at Max. Rated Control Circuit Voltage DC 4 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·APull-in at Max. Rated Control Circuit Voltage DC 230 W
- Operate Time
- Between Coil De-energization and NO Contact Opening 37 ... 47 msBetween Coil Energization and NO Contact Closing 25 ... 55 ms
- Connecting Capacity Main Circuit
- Flexible 1 x 10 ... 70 mm²Rigid Cu-Cable 1 x 10 ... 95 mm²
- Connecting Capacity Auxiliary Circuit
- Flexible with Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 1x0.75 ... 2.5 mm²Solid 1 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Terminal Type
- Main Circuit: Bars
Eco Transparency
- Environmental Product Declaration - EPD
- 1SFC100092D0201
Classifications
- Object Classification Code
- Q
- ETIM 4
- EC000066 - Magnet contactor, AC-switching
- ETIM 5
- EC000066 - Magnet contactor, AC-switching
- EClass
- V11.0 : 27371003
- IDEA Granular Category Code (IGCC)
- 4758 >> Iec Contactors
- E-Number (Finland)
- 3706385
- E-Number (Norway)
- 4117636
- E-Number (Sweden)
- 3210127
Environmental
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Circular Value
- ABB EcoSolutions
- Yes
- Circular Design Principles Recyclability Rate
- Design for Closing Resource Loops - Standard EN45555 - 87.8 %
- End of Life Instructions
- 1SFC100112M0001
- Group Waste to Landfill Target
- Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
- Improved Resource Efficiency for Customers
- Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
- Sustainable Material Content
- Recycled Metal - 37 %
Technical UL/CSA
- Maximum Operating Voltage UL/CSA
- Main Circuit 1000 V
- General Use Rating UL/CSA
- (600 V AC) 200 A
- Horsepower Rating UL/CSA
- (200 V AC) Three Phase 40 hp(208 V AC) Three Phase 40 hp(220 ... 240 V AC) Three Phase 50 hp(440 ... 480 V AC) Three Phase 100 hp(550 ... 600 V AC) Three Phase 125 hp
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900