ABB

S201-K32

1 / 4
thumbnail
thumbnail
thumbnail
thumbnail

Description

System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Part Number
S201-K32
UPC
40167794961310
UNSPSC
39121603
€4.52
net
€5.03
Shipping from:
€40.00
1
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 19-11-2024
Warranty:
24 months
Estimated Delivery:
28 November - 02 December to United Kingdom
Condition:
Refurbished
Refurbished - A refurbished item inspected, cleaned, and repaired to full working order by either the manufacturer or a certified technician. The item is in excellent condition and fully operational.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Installation

Instructions and Manuals
2CDS207104P0002

Dimensions

Width in Number of Modular Spacings
1
Product Net Width
17.5 mm
Product Net Height
88 mm
Product Net Depth / Length
69 mm
Product Net Weight
0.125 kg
Pole Net Weight
0.125 kg
Built-In Depth (t2)
69 mm
Dimension Diagram
2CDC022007F0010

ABB EcoSolutions

ABB EcoSolutions
Yes

Technical

Standards
IEC/EN 60898-1IEC/EN 60947-2UL 1077
Tripping Characteristic
K
Rated Operational Voltage
acc. to IEC 60898-1 230 / 400 V ACacc. to IEC 60947-2 230 V AC
Operational Voltage
Maximum (Incl. Tolerance) 253 V ACMaximum (Incl. Tolerance) 72 V DC
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp)
4 kVat 2000 m 5 kVat Sea Level 6.2 kV
Dielectric Test Voltage
50/60 Hz, 1 min: 2 kV
Input Voltage Type
AC/DC
Rated Current (In)
32 A
Rated Short-Circuit Capacity
(AC) 6 kA(DC) 6 kA(230 V AC) 6 kA(400 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(133 V AC) 20 kA(230 V AC) 10 kA(24 V DC) 20 kA(60 V DC) 10 kA
Rated Conditional Short-Circuit Current (Inc)
(230 V) 10 kA(400 V) 10 kA
Rated Service Short-Circuit Breaking Capacity (Ics)
(133 V AC) 15 kA(230 V AC) 7.5 kA
Frequency (f)
50 Hz
Rated Frequency (f)
50 / 60 Hz
Power Loss
3.6 Wat Rated Operating Conditions per Pole 3.6 W
Power Supply Connection
Arbitrary
Contact Position Indication
Red ON / Green OFF
Electrical Endurance
10000 AC cycle
Mechanical Endurance
20000 cycle
Number of Poles
1
Number of Protected Poles
1
Overvoltage Category
III
Tightening Torque
2.8 N·m
Mounting Type
DIN-Rail
Screw Terminal Type
Failsafe Bi-directional Cylinder-lift Terminal
Actuator Marking
I / O
Actuator Material
Insulation Group II, Black, Sealable
Housing Material
Insulation Group II, RAL 7035
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Position
any
Recommended Screw Driver
Pozidriv 2
Accessories Available
Yes
Connecting Capacity
Busbar 10 / 10 mm²Flexible with Ferrule 0.75 ... 25 mm²Flexible 0.75 ... 25 mm²Rigid 0.75 ... 35 mm²Stranded 0.75 ... 35 mm²
Installation Size
acc. to DIN 43880 1
Wire Stripping Length
12.5 mm
Terminal Type
Screw Terminals

Eco Transparency

Environmental Product Declaration - EPD
9AKK108467A7832

Classifications

ETIM 9
EC000042 - Miniature circuit breaker (MCB)
EPLAN Function Definition
Circuit breaker / Single circuit breaker / Circuit breaker 1_2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Business
CN8
8536 20 10
EClass
V11.0 : 27141901
IDEA Granular Category Code (IGCC)
4897 >> Miniature circuit breakers
Object Classification Code
F

Environmental

Ambient Air Temperature
Operation -25 ... +55 °CStorage -40 ... +70 °C
Degree of Protection
IP20Enclosure with Cover IP40
Pollution Degree
3
Environmental Conditions
28 cycleswith 55 °C / 90-96 %and 25 °C / 95-100 %
Resistance to Vibrations acc. to IEC 60068-2-6
5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
Resistance to Shock acc. to IEC 60068-2-27
25g 2 shocks 13 ms
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Information
2CDK403001D0607
REACH Declaration
9AKK107492A1906
SCIP
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany (DE)

Circular Value

Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 90 %
Sustainable Material Content
0 %
Offered with Extended Lifetime
Product Durability
Offered with Takeback Services
Take Back for Recycling

Technical UL/CSA

Maximum Operating Voltage UL/CSA
60 V DC480Y / 277 V AC
Interrupting Rating acc. to UL1077
(277 V AC) 6 kA(60 V DC) 10 kA(120 V) 10 kA
Connecting Capacity UL/CSA
Busbar 18-8 AWGConductor 18-4 AWG
Tightening Torque UL/CSA
18 in·lb

Ordering

Minimum Order Quantity
1 piece
Package Level 1 Units
carton 10 piece
Package Level 1 Gross Weight
1.295 kg
E-Number (Finland)
3210690
E-Number (Sweden)
2100701