- Contact type
- 4 enabling current paths
- Contact type
- 2 semiconductor alarm outputs
- Contact material
- AgCuNi, +0.2 -0.4 µm Au
- Maximum switching voltage
- 250 V AC/DC
- Minimum switching voltage
- 10 V AC/DC
- Limiting continuous current
- 6 A (N/O contact)
- Limiting continuous current
- max. 100 mA (Alarm output (24 V DC))
- Maximum inrush current
- 6 A
- Inrush current, minimum
- 10 mA
- Sq. Total current
- 72 A² (TH² = I₁² + I₂²+ I₃²+ I₄² (note derating))
- Interrupting rating (ohmic load) max.
- 1500 VA (250 V AC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 66 W (220 V DC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 66 W (110 V DC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 100 W (48 V DC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 144 W (24 V DC, τ = 0 ms)
- Maximum interrupting rating (inductive load)
- 48 W (24 V DC, τ = 40 ms)
- Maximum interrupting rating (inductive load)
- 43 W (48 V DC, τ = 40 ms)
- Switching capacity min.
- 0.1 W
- Mechanical service life
- 10x 10⁶ cycles
- Switching capacity (360/h cycles)
- 5 A (0,1 Hz; DC13; 24 V)
- Output fuse
- 6 A gL/gG NEOZED (N/O contact)
- Output fuse
- 4 A gL/gG NEOZED (for low-demand applications)