Schmersal
101209551
1 / 4
- Part Number
- 101209551
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Position switch with guard locking
- Class Code : EC002593
- Version : 7
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 6 pcs.In-StockUpdated at: 19-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Electrical data
- Time to readiness, maximum
- 4,000 ms
Electrical data - AS-Interface specification
- AS-i Specification
- Safety-Slave
- AS-i Version
- V 2.1
- AS-i Profile
- S-7.B.F.E
- AS-i, IO-Code
- 0x7
- AS-i, ID-Code
- 0xB
- AS-i, ID-Code1
- 0xF
- AS-i, ID-Code2
- 0xE
- AS-i Input, Channel 1
- Data bits DI 0 / DI 1 = dynamic code transmission
- AS-i Input, Channel 2
- Data bits DI 2 / DI 3 = dynamic code transmission
- AS-i Outputs, DO 0
- Solenoid control
- AS-i Outputs, DO 1
- For the variable setting of the latching force
- AS-i Outputs, DO 2
- For the variable setting of the latching force
- AS-i Outputs, DO 3
- For the variable setting of the latching force
- AS-i Parameter bits, P0
- Actuator in
- AS-i Parameter bits, P1
- Solenoid interlock locked
- AS-i Parameter bits, P2
- Auxiliary voltage in
- AS-i Parameter bits, P3
- Device error (fault detected)
- Note (AS-i Parameter bits)
- Set the parameter outputs to "1111" (0xF)
- AS-i Input module address
- 0
- Note (AS-i Input module address)
- Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note
- Note (General)
- Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
Mechanical data - Dimensions
- Length of sensor
- 40 mm
- Width of sensor
- 40 mm
- Height of sensor
- 179 mm
Pin assignment
- PIN 1
- AS-i +
- PIN 2
- Aux - (P)
- PIN 3
- AS-Interface -
- PIN 4
- Aux + (P)
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
Electrical data - Magnet control
- Magnet switch-on time
- 100 %
General data - Features
- Power to lock
- Yes
- Actuator monitored
- Yes
- Latching
- Yes
- Safety functions
- Yes
- Integral system diagnostics, status
- Yes
General data
- Standards
- EN IEC 62026-2 | EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
- Coding
- Universal coding
- Coding level according to EN ISO 14119
- Low
- Working principle
- inductive
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 631 g
- Reaction time, maximum
- 150 ms
- Duration of risk, maximum
- 150 ms
Safety classification
- Standards
- EN IEC 60947-5-3 | EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 5.00 x 10⁻⁹ /h
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - AS Interface
- Rated operating voltage
- 26.5 ... 31.6 VDC (Protection against polarity reversal)
- AS-i Current consumption, maximum
- 100 mA
Ambient conditions
- Degree of protection
- IP67
- Ambient temperature
- -25 ... +55 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Relative humidity, minimum
- 30 %
- Relative humidity, maximum
- 95 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations
- 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- III
Mechanical data - Connection technique
- Termination
- Connector plug M12, 4-pole, (A-coding)
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical life)
- Actuating speed ≤ 0.5 m/s | Operations for door weights ≤ 5 kg
- Holding force, typically
- 750 N
- Holding force, guaranteed
- 500 N
- Latching force, minimum
- 30 N
- Latching force, maximum
- 100 N
Accessory
- Recommendation (actuator)
- MZM 100-B1.1
Approvals - Standards
- Certificates
- TÜV | cULus | ASi-SaW | UKCA
Electrical data - Auxiliary voltage
- Operating voltage
- 24 VDC -15 % / +10 % (stabilised PELV power supply)
- Current consumption
- 600 mA
- Rated operating voltage
- 24 VDC
Status indication
- Note (LED switching conditions display)
- (1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0 | (2) LED yellow: Device condition | (3) LED red: Internal device error
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories