Need more information?

Call us at:+48 17 778 34 19

Schneider Electric LA1KN40

Auxiliary contact block, TeSys K, 4NO, front mounting, screw clamp terminals

1 / 1
Schneider Electric LA1KN40 Auxiliary contact block, TeSys K, 4NO, front mounting, screw clamp terminals — PLCs
Manufacturer catalogue image

Product Description

Lifecycle Status:
TeSys K instantaneous auxiliary contact block, for contactors LC.K, LP.K, CA.K with screw clamp terminals (except LP4K, LP5K, CA4K). It provides 4NO contacts rated up to 10A 690V AC, connection by screw clamp terminals. Front mounting by clip-on, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC), Green Premium compliant (RoHS/REACh).
Send Inquiry
Payment methods:

Offer details

Best offer from:
Trusted supplier — France, member since 2021
Availability:
1 pc.
On Request
Updated at: 24-08-2026
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
The Seller is responsible for shipping the product and invoicing

Specifications

Ambient Air Temperature For Operation
-25-50 °C
Ip Degree Of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature For Storage
-50-80 °C
Environmental Characteristic
normal environment
Protective Treatment
TC IEC 60068
Operating Altitude
6561.68 ft (2000 m)

Available Offers

(11)
Best offer
LA1KN40 Schneider Electric, PLCs

Schneider Electric

Available:
2 pcs.
In-Stock
Updated at: 31-10-2025
Offer from:
Trusted supplier — United Kingdom, member since 2021
LA1KN40 Schneider Electric, PLCs

Schneider Electric

Available:
3 pcs.
In-Stock
Updated at: 31-10-2025
Offer from:
Trusted supplier — United Kingdom, member since 2021
LA1KN40 Schneider Electric, PLCs

Schneider Electric

Available:
7 pcs.
In-Stock
Updated at: 31-10-2025
Offer from:
Trusted supplier — United Kingdom, member since 2021

Access our platform to find more offers

Register now to explore 36 mln offers from verified suppliers worldwide.Including 7 more offers for this product.

  • Compare offers globally
  • Direct supplier contact
  • RFQs, Quotes, and Orders
  • BOM Search
Sign UpFree 14-day trial available
Offer with manufacturer lead time
Directly from the manufacturer - with a confirmed, predictable, and fully transparent delivery time.
Get Quote

Documents

Data Sheet

Datasheet for Schneider Electric LA1KN40, including specifications and features.

Download Data Sheet
TracePartsTraceParts

CAD Models

3D CAD model and technical drawings, ready for your design software.

Download CAD Model

Compatible Products

CA2KN22B7 Schneider Electric
CA2KN22B7
Schneider Electric
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN22E7 Schneider Electric
CA2KN22E7
Schneider Electric
Control relay featuring 4 contacts (2NO + 2NC), rated for 10A at 690V, designed for controlling electromagnetic loads in AC-15/DC-13 applications.
CA2KN22F7 Schneider Electric
CA2KN22F7
Schneider Electric
Control relay with 4 contacts (2NO + 2NC), rated for 10A at 690V, designed for controlling electromagnetic loads in AC-15/DC-13 applications.
CA2KN22G7 Schneider Electric
CA2KN22G7
Schneider Electric
Control relay with 4 contacts (2NO + 2NC), rated for 10A at 690V, designed for electromagnetic load control AC-15/DC-13.
CA2KN22M7 Schneider Electric
CA2KN22M7
Schneider Electric
Control relay with 4 contacts (2NO + 2NC), rated at 10A/690V, designed for controlling electromagnetic loads under AC-15/DC-13 applications.
CA2KN22P7 Schneider Electric
CA2KN22P7
Schneider Electric
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN22P72 Schneider Electric
CA2KN22P72
Schneider Electric
Control relay with 4 contacts (2NO + 2NC), rated for 10A at 690V, designed for controlling electromagnetic loads in AC-15/DC-13 applications.
CA2KN22U7 Schneider Electric
CA2KN22U7
Schneider Electric
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN31B7 Schneider Electric
CA2KN31B7
Schneider Electric
TeSys K control relay, 4 contacts (3NO + 1NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN31F7 Schneider Electric
CA2KN31F7
Schneider Electric
TeSys K control relay, 4 contacts (3NO + 1NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN31M7 Schneider Electric
CA2KN31M7
Schneider Electric
TeSys K control relay, 4 contacts (3NO + 1NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN31P7 Schneider Electric
CA2KN31P7
Schneider Electric
TeSys K control relay, 4 contacts (3NO + 1NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN31P72 Schneider Electric
CA2KN31P72
Schneider Electric
Control relay with 4 contacts (3NO + 1NC), rated for 10A/690V, suitable for controlling electromagnetic loads AC-15/DC-13.
CA2KN40B7 Schneider Electric
CA2KN40B7
Schneider Electric
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN40E7 Schneider Electric
CA2KN40E7
Schneider Electric
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN40F7 Schneider Electric
CA2KN40F7
Schneider Electric
The TeSys K control relay offers 4 contacts with a maximum voltage of 690V and is designed for the control of electromagnetic loads.
CA2KN40G7 Schneider Electric
CA2KN40G7
Schneider Electric
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA2KN40M7 Schneider Electric
CA2KN40M7
Schneider Electric
Control relay with 4 normally open contacts, rated for 10A and 690V, designed for electromagnetic load control in AC-15/DC-13 applications.
CA2KN40P7 Schneider Electric
CA2KN40P7
Schneider Electric
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN22BD Schneider Electric
CA3KN22BD
Schneider Electric
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN22BD3 Schneider Electric
CA3KN22BD3
Schneider Electric
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN22ED Schneider Electric
CA3KN22ED
Schneider Electric
Control relay featuring 4 contacts (2NO + 2NC), rated for 10A at 690V, designed for controlling electromagnetic loads in AC-15/DC-13 applications.
CA3KN22FD Schneider Electric
CA3KN22FD
Schneider Electric
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN22GD Schneider Electric
CA3KN22GD
Schneider Electric
Control relay with 4 contacts (2NO/2NC), rated for 10A at 690V, designed for controlling electromagnetic loads AC-15/DC-13.
CA3KN22JD Schneider Electric
CA3KN22JD
Schneider Electric
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN22MD Schneider Electric
CA3KN22MD
Schneider Electric
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN31BD Schneider Electric
CA3KN31BD
Schneider Electric
TeSys K control relay, 4 contacts (3NO + 1NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN31BD3 Schneider Electric
CA3KN31BD3
Schneider Electric
Control relay featuring 4 contacts (3NO + 1NC), rated for 10A at 690V, suitable for controlling electromagnetic loads AC-15/DC-13.
CA3KN31ED Schneider Electric
CA3KN31ED
Schneider Electric
Control relay featuring 4 contacts (3NO + 1NC) with a current rating of 10A at 690V, designed for controlling electromagnetic loads in AC-15 and DC-13 applications.
CA3KN31FD Schneider Electric
CA3KN31FD
Schneider Electric
TeSys K control relay with 4 contacts (3 normally open + 1 normally closed) for controlling electromagnetic loads up to 690V and 10A.
CA3KN31JD Schneider Electric
CA3KN31JD
Schneider Electric
TeSys K control relay, 4 contacts (3NO + 1NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN31MD Schneider Electric
CA3KN31MD
Schneider Electric
TeSys K control relay with 4 contacts for electromagnetic load control, rated at 10A and up to 690V.
CA3KN40BD Schneider Electric
CA3KN40BD
Schneider Electric
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN40BD3 Schneider Electric
CA3KN40BD3
Schneider Electric
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN40FD Schneider Electric
CA3KN40FD
Schneider Electric
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13
CA3KN40GD Schneider Electric
CA3KN40GD
Schneider Electric
TeSys K IEC industrial control relays are used in industrial control circuits
CA3KN40MD Schneider Electric
CA3KN40MD
Schneider Electric
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13
LC1K06015B7 Schneider Electric
LC1K06015B7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC1K0601B7 Schneider Electric
LC1K0601B7
Schneider Electric
TeSys K contactor with 3 poles for motor control applications rated up to 6A at 440V AC-3, featuring a 24VAC control coil and one normally closed auxiliary contact.
LC1K0601E7 Schneider Electric
LC1K0601E7
Schneider Electric
This 3-pole TeSys K contactor is designed for motor control applications, rated for 6A at 440V AC-3 and features a 48V AC coil with one normally closed auxiliary contact.
LC1K0601F7 Schneider Electric
LC1K0601F7
Schneider Electric
The TeSys K contactor features a 3-pole configuration for motor control applications, rated for 6A at 440V AC-3.
LC1K0601M7 Schneider Electric
LC1K0601M7
Schneider Electric
3-pole TeSys K contactor designed for motor control applications rated up to 6A and 690V AC-3, with a 220V 50/60Hz AC coil and 1 NC auxiliary contact.
LC1K0601P7 Schneider Electric
LC1K0601P7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC1K06105B7 Schneider Electric
LC1K06105B7
Schneider Electric
The Schneider Electric TeSys K contactor is a reliable and durable solution for motor control applications, capable of handling up to 6A/690V AC-3 (2.2kW@400V) with a 24V 50/60Hz AC coil.
LC1K0610B7 Schneider Electric
LC1K0610B7
Schneider Electric
Compact 3-pole TeSys K contactor for motor applications, rated 6A AC-3 2.2kW@400V, with 24V AC coil and 1NO auxiliary contact.
LC1K0610E7 Schneider Electric
LC1K0610E7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC1K0610F7 Schneider Electric
LC1K0610F7
Schneider Electric
Schneider Electric's compact TeSys K contactor for motor applications up to 2.2kW at 400V.
LC1K0610G7 Schneider Electric
LC1K0610G7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC1K0610M7 Schneider Electric
LC1K0610M7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC1K0610M72 Schneider Electric
LC1K0610M72
Schneider Electric
"TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (3kW@400V)," "and for non-inductive load control applications up to 20A/690V AC-1
LC1K0610P7 Schneider Electric
LC1K0610P7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC1K0610Q7 Schneider Electric
LC1K0610Q7
Schneider Electric
"TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (3kW@400V)," "and for non-inductive load control applications up to 20A/690V AC-1
LC1K0610T7 Schneider Electric
LC1K0610T7
Schneider Electric
Three-pole contactor designed for motor control applications up to 6A at 440V, featuring a 480VAC coil and one normally open auxiliary contact.
LC1K0610U7 Schneider Electric
LC1K0610U7
Schneider Electric
3-pole TeSys K contactor designed for motor control applications rated up to 6A at 690V AC-3.
LC1K09004B7 Schneider Electric
LC1K09004B7
Schneider Electric
4-pole (4NO) contactor designed for non-inductive load control applications rated up to 20A and 690V AC-1.
LC1K09004M7 Schneider Electric
LC1K09004M7
Schneider Electric
4-pole (4NO) contactor designed for non-inductive load control applications up to 20A/690V AC-1.
LC1K09004P7 Schneider Electric
LC1K09004P7
Schneider Electric
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1
LC1K09004U7 Schneider Electric
LC1K09004U7
Schneider Electric
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1
LC1K090085E7 Schneider Electric
LC1K090085E7
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1
LC1K090085F7 Schneider Electric
LC1K090085F7
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1
LC1K09008B7 Schneider Electric
LC1K09008B7
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V 50/60Hz AC coil without built-in auxiliary contact.
LC1K09008B7TQ Schneider Electric
LC1K09008B7TQ
Schneider Electric
TeSys K contactor, 4 poles (2NO/2NC), for motor control applications up to 9A/690V AC-3 (4kW/400V)
LC1K09008E7 Schneider Electric
LC1K09008E7
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1
LC1K09008F7 Schneider Electric
LC1K09008F7
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1
LC1K09008G7 Schneider Electric
LC1K09008G7
Schneider Electric
Contactor with 4 poles (2NO + 2NC) designed for non-inductive load control up to 20A/690V AC-1.
LC1K09008M7 Schneider Electric
LC1K09008M7
Schneider Electric
4-pole contactor with 2 normally open (NO) and 2 normally closed (NC) contacts designed for non-inductive load control applications up to 20A/690V AC-1.
LC1K09008P7 Schneider Electric
LC1K09008P7
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1
LC1K09017B7 Schneider Electric
LC1K09017B7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0901B7 Schneider Electric
LC1K0901B7
Schneider Electric
Compact and DIN-rail compatible TeSys K contactor from Schneider Electric for simple motor applications rated up to 4kW@400V. Includes a 24V AC coil and 1NC auxiliary contact.
LC1K0901E7 Schneider Electric
LC1K0901E7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0901F7 Schneider Electric
LC1K0901F7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0901M7 Schneider Electric
LC1K0901M7
Schneider Electric
3-pole contactor for motor control applications rated at 9A and suitable for loads up to 4kW at 400V AC.
LC1K0901P7 Schneider Electric
LC1K0901P7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0901U7 Schneider Electric
LC1K0901U7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K09105E7 Schneider Electric
LC1K09105E7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K09105F7 Schneider Electric
LC1K09105F7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0910B7 Schneider Electric
LC1K0910B7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0910B7TQ Schneider Electric
LC1K0910B7TQ
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0910E7 Schneider Electric
LC1K0910E7
Schneider Electric
3-pole TeSys K contactor for motor control applications rated up to 9A/690V AC-3 (4kW@400V), featuring an auxiliary contact.
LC1K0910F7 Schneider Electric
LC1K0910F7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0910G7 Schneider Electric
LC1K0910G7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0910M7 Schneider Electric
LC1K0910M7
Schneider Electric
3-pole TeSys K contactor for motor control applications rated up to 9A/690V AC-3 and 20A/690V AC-1.
LC1K0910P7 Schneider Electric
LC1K0910P7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0910Q7 Schneider Electric
LC1K0910Q7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K0910U7 Schneider Electric
LC1K0910U7
Schneider Electric
3-pole TeSys K contactor suitable for motor control applications, rated for 9A AC-3 at up to 4kW@400V, equipped with a 240VAC coil and 1NO auxiliary contact.
LC1K0910V7 Schneider Electric
LC1K0910V7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LC1K12004P7 Schneider Electric
LC1K12004P7
Schneider Electric
Contactor with 4 poles (4NO) designed for controlling non-inductive loads up to 20A/690V AC-1.
LC1K1201B7 Schneider Electric
LC1K1201B7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC1K1201F7 Schneider Electric
LC1K1201F7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC1K1201M7 Schneider Electric
LC1K1201M7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC1K1201P7 Schneider Electric
LC1K1201P7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC1K1210B7 Schneider Electric
LC1K1210B7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC1K1210F7 Schneider Electric
LC1K1210F7
Schneider Electric
TeSys K contactor with three poles for motor control applications rated at 12A and 440V AC-3, featuring a 110V AC coil and one normally open auxiliary contact.
LC1K1210G7 Schneider Electric
LC1K1210G7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC1K1210M7 Schneider Electric
LC1K1210M7
Schneider Electric
The TeSys K contactor is a 3-pole device for motor control applications rated up to 12A and 690V AC-3, featuring a 220V AC coil.
LC1K1210P7 Schneider Electric
LC1K1210P7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC1K1210Q7 Schneider Electric
LC1K1210Q7
Schneider Electric
Three-pole contactor designed for motor control applications up to 12A at 690V AC-3, featuring a 380-400V AC coil and one normally open auxiliary contact.
LC1K1210U7 Schneider Electric
LC1K1210U7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC1K1610B7 Schneider Electric
LC1K1610B7
Schneider Electric
The TeSys K Contactor is a reliable solution for motor control applications, offering compact design and high performance.
LC1K1610P7 Schneider Electric
LC1K1610P7
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 16A/690V AC-3 (7
LC2K0601B7 Schneider Electric
LC2K0601B7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC2K0601B72 Schneider Electric
LC2K0601B72
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC2K0601F7 Schneider Electric
LC2K0601F7
Schneider Electric
The TeSys K reversing contactor is a compact and reliable solution for motor applications. It is rated up to 2.2kW at 400V with a 110V AC coil and 2NC auxiliary contacts.
LC2K0601P7 Schneider Electric
LC2K0601P7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC2K0610B7 Schneider Electric
LC2K0610B7
Schneider Electric
The LC2K0610B7 is a compact TeSys K reversing contactor from Schneider Electric for motor applications. It's rated at 6A AC-3 and has a 24V AC coil, 2NO auxiliary contacts, a mechanical interlock, and pre-wired reversing circuit.
LC2K0610P7 Schneider Electric
LC2K0610P7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LC2K09015E7 Schneider Electric
LC2K09015E7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LC2K09015F7 Schneider Electric
LC2K09015F7
Schneider Electric
"TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)," "and for non-inductive load control applications up to 20A/690V AC-1
LC2K0901B7 Schneider Electric
LC2K0901B7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LC2K0901E7 Schneider Electric
LC2K0901E7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LC2K0901F7 Schneider Electric
LC2K0901F7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LC2K0901G7 Schneider Electric
LC2K0901G7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LC2K0901M7 Schneider Electric
LC2K0901M7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LC2K0901P7 Schneider Electric
LC2K0901P7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LC2K0910B7 Schneider Electric
LC2K0910B7
Schneider Electric
Compact and reliable 3-pole TeSys K reversing contactor from Schneider Electric for motor applications rated up to 4kW@400V.
LC2K0910E7 Schneider Electric
LC2K0910E7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LC2K0910M7 Schneider Electric
LC2K0910M7
Schneider Electric
3-pole reversing contactor designed for motor control applications with a rating of 9A/690V AC-3 (4kW@400V).
LC2K0910P7 Schneider Electric
LC2K0910P7
Schneider Electric
3-pole reversing contactor for motor control applications, rated at 9A AC-3 with a 230VAC coil.
LC2K1201B7 Schneider Electric
LC2K1201B7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC2K12107B7 Schneider Electric
LC2K12107B7
Schneider Electric
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NO, 24VAC coil
LC2K1210B7 Schneider Electric
LC2K1210B7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC2K1210F7 Schneider Electric
LC2K1210F7
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LC7K0901M7 Schneider Electric
LC7K0901M7
Schneider Electric
TeSys K contactor, 3 poles (3NO), 9A/690V AC-3, for motor applications up to 4kW@400V
LP1K0601BD Schneider Electric
LP1K0601BD
Schneider Electric
TeSys K 3-Pole Contactor designed for motor control applications, rated for 6A at up to 440V with a 24V DC coil and 1 NC auxiliary contact.
LP1K0601BD3 Schneider Electric
LP1K0601BD3
Schneider Electric
This contactor is designed for motor control applications with a current rating of up to 6A and operational voltage of 690V AC-3.
LP1K0601ED Schneider Electric
LP1K0601ED
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LP1K06105BD Schneider Electric
LP1K06105BD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LP1K0610BD Schneider Electric
LP1K0610BD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LP1K0610BD3 Schneider Electric
LP1K0610BD3
Schneider Electric
Contactor with three poles designed for motor control applications, supporting operational currents up to 6A at 690V AC-3.
LP1K0610JD Schneider Electric
LP1K0610JD
Schneider Electric
The Schneider Electric TeSys K Contactor is a reliable and compact solution for motor control applications. It offers a maximum load capacity of 6A/690V AC-3 (2.2kW@400V) with a 12V DC coil, 1 NO built-in auxiliary contact, and screw clamp terminals.
LP1K0610MD Schneider Electric
LP1K0610MD
Schneider Electric
3-pole contactor for motor control applications rated up to 6A at 690V AC-3 and suitable for non-inductive loads up to 20A at 690V AC-1.
LP1K090045BD Schneider Electric
LP1K090045BD
Schneider Electric
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1
LP1K09004BD Schneider Electric
LP1K09004BD
Schneider Electric
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1
LP1K09004BD3 Schneider Electric
LP1K09004BD3
Schneider Electric
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1
LP1K09004JD Schneider Electric
LP1K09004JD
Schneider Electric
Contactor with 4 poles (4NO) designed for non-inductive load control applications up to 20A/690V AC-1.
LP1K090085MD Schneider Electric
LP1K090085MD
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1
LP1K09008BD Schneider Electric
LP1K09008BD
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1
LP1K09008MD Schneider Electric
LP1K09008MD
Schneider Electric
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1
LP1K0901BD Schneider Electric
LP1K0901BD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LP1K0901BD3 Schneider Electric
LP1K0901BD3
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LP1K0901FD Schneider Electric
LP1K0901FD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LP1K0901JD Schneider Electric
LP1K0901JD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LP1K09105BD Schneider Electric
LP1K09105BD
Schneider Electric
3-pole contactor for motor control applications with a rated operational current of 9A at 440V AC-3 and non-inductive load control up to 20A at 690V AC-1.
LP1K0910BD Schneider Electric
LP1K0910BD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LP1K0910BD3 Schneider Electric
LP1K0910BD3
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LP1K0910ED Schneider Electric
LP1K0910ED
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1
LP1K0910FD Schneider Electric
LP1K0910FD
Schneider Electric
Three-pole contactor designed for motor control applications up to 9A at 690V AC-3 and non-inductive loads up to 20A at 690V AC-1, featuring a 110V DC coil and one built-in auxiliary contact.
LP1K0910JD Schneider Electric
LP1K0910JD
Schneider Electric
Contactor with 3 poles (3NO) designed for motor control applications up to 9A/690V AC-3 (4kW@400V) and non-inductive load control up to 20A/690V AC-1.
LP1K12004BD Schneider Electric
LP1K12004BD
Schneider Electric
The TeSys K contactor is a versatile solution for non-inductive load control applications. It features a 24V DC coil and can handle up to 20A/690V AC-1.
LP1K1201BD Schneider Electric
LP1K1201BD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LP1K1201BD3 Schneider Electric
LP1K1201BD3
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LP1K12105BD Schneider Electric
LP1K12105BD
Schneider Electric
The TeSys K Contactor is a robust solution for motor control applications up to 12A/690V AC-3 (5.5kW@400V) and non-inductive load control applications up to 20A/690V AC-1.
LP1K1210BD Schneider Electric
LP1K1210BD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LP1K1210BD3 Schneider Electric
LP1K1210BD3
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LP1K1210JD Schneider Electric
LP1K1210JD
Schneider Electric
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LP2K0601BD Schneider Electric
LP2K0601BD
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LP2K0610BD Schneider Electric
LP2K0610BD
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LP2K09015BD Schneider Electric
LP2K09015BD
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V)
LP2K0901BD Schneider Electric
LP2K0901BD
Schneider Electric
This compact 3-pole TeSys K reversing contactor features a 24V DC coil, 1NC auxiliary contact, and integrated mechanical interlock for reliable motor control.
LP2K0901BD3 Schneider Electric
LP2K0901BD3
Schneider Electric
The TeSys K reversing contactor is a reliable and durable solution for motor control applications, offering a compact design and multiple mounting options.
LP2K0910BD Schneider Electric
LP2K0910BD
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2
LP2K0910BD3 Schneider Electric
LP2K0910BD3
Schneider Electric
Schneider Electric's TeSys K reversing contactor is a reliable solution for motor control applications.
LP2K1201BD Schneider Electric
LP2K1201BD
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5
LP2K1210BD Schneider Electric
LP2K1210BD
Schneider Electric
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5

Market insights

AutomaINSIGHTS analytics dashboard

Get real-time analytics and market data to optimize your purchasing decisions for this component and similar products

  • Real-time stock availability data from 700 MRO distributors in Europe and USA
  • Price analysis by condition (new, used, refurbished) with market median prices
  • Critical component availability monitoring to prevent production downtime
  • Inventory optimization insights based on market supply trends
Get Started