1 / 1
thumbnail

Description

Active Mature
TeSys K IEC motor control contactors are used in industrial control applications. This Type K IEC nonreversing contactor has 3 normally open contacts. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 2HP at 200 to 208VAC, 3HP at 240VAC, 5HP at 480VAC and 5HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 1.5HP at 240VAC single phase. The IEC contactor has a 200/208 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. Contactor is supplied with one normally open auxiliary contact. The contactor is 2.28 inches tall, 1.77 inches wide and 2.24 inches deep. It weighs 0.40 lbs. This IEC contactor is UL Listed and CSA certified.
Country of Origin
FR
Part Number
LC1K0910L7
Tariff Code
85364900
EAN
3389110374711
UNSPSC
39121529
Payment methods:
Best offer from:
CZTrusted Automa.Net Supplier
Availability:
2 pcs.
In-Stock
Updated at: 22-11-2024
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 31 Parts In-Stock from 14 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (14)

Best offer
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
FRTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€37.35
net
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
£37.40
net
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
NLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€38.29
net
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
LVTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
€38.58
net
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€43.21
net
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€44.30
net
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
ESTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€45.68
net
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
PLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
199,35 zł
net
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Factory Sealed
Available:
2 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
ROTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
LC1K0910L7 product image
Schneider Electric

LC1K0910L7

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 21-10-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
€11.54

Environment

Product Certifications
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Standards
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Flame Retardance
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Protective Treatment
TC IEC 60068 || TC DIN 50016
Operating Altitude
6561.68 ft (2000 m) without derating

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1503003EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
ENVEOLI1503003EN
Eu Rohs Directive
Compliant

Complementary

Minimum Switching Current
5 mA for signalling circuit
Mechanical Robustness
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
[Uc] Control Circuit Voltage
200...208 V AC 50/60 Hz
[Ue] Rated Operational Voltage
power circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz
Height
58 mm
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Auxiliary Contact Composition
1 NO
Control Circuit Voltage Limits
operational: 0.8...1.15 Uc (at <50 °C) || drop-out: >= 0.20 Uc (at <50 °C)
Non Overlap Distance
0.5 mm
[Ith] Conventional Free Air Thermal Current
20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Control Circuit Type
AC 50/60 Hz
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance
> 10 MOhm for signalling circuit
Rated Breaking Capacity
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Irms Rated Making Capacity
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947
Motor Power Kw
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/60 Hz AC-4 || 4 kW 380...415 V AC 50/60 Hz AC-4 || 4 kW 440/690 V AC 50/60 Hz AC-4
Associated Fuse Rating
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660
[Uimp] Rated Impulse Withstand Voltage
8 kV
Inrush Power In Va
30-30 VA (at 20 °C)
Connections - Terminals
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Pole Contact Composition
3 NO
Utilisation Category
AC-3 || AC-3e || AC-1 || AC-4
[Ie] Rated Operational Current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Minimum Switching Voltage
17 V for signalling circuit
Maximum Operating Rate
3600 cyc/h
Signalling Circuit Frequency
<= 400 Hz
Electrical Durability
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Mechanical Durability
10 Mcycles
Auxiliary Contacts Type
instantaneous 1 NO
Poles Description
3P
Hold-In Power Consumption In Va
4.5-4.5 VA (at 20 °C)
Operating Time
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Width
45 mm
Overvoltage Category
III
Depth
57 mm
[Icw] Rated Short-Time Withstand Current
90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit
Heat Dissipation
1.3-1.3 W

Specifications

Contactor Application
motor control || resistive load
Product Or Component Type
contactor
Range
TeSys
Device Application
control

CAD Models

traceparts
traceparts
Download