- Product Certifications
- CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
- Height
- 154 mm
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Maximum Operating Rate
- 3600 cyc/h
- Connections - Terminals
- control circuit screw clamp terminals 1 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² rigid || power circuit screw clamp terminals 1 1-10 mm² rigid || power circuit screw clamp terminals 1 1-6 mm² flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² rigid || power circuit screw clamp terminals 2 1.5-6 mm² flexible without cable end
- Net Weight
- 0.9 kg
- Fixing Mode
- clipped DIN rail) || screw-fixed plate)
- [Uimp] Rated Impulse Withstand Voltage
- 6 kVIEC 60947-6-2
- Standards
- EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
- [Ui] Rated Insulation Voltage
- 690 V IEC 60947-6-2 3) || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
- Typical Current Consumption
- 130 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 140 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 150 mA 24 V DC I maximum while closing with LUCM || 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 35 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 35 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 35 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 35 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 60 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 70 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 70 mA 24 V DC I rms sealed with LUCM
- Mechanical Durability
- 15 Mcycles
- Compatibility Code
- LUB
- Operating Time
- 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit || 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 75 ms closing with LUCM control circuit
- Width
- 45 mm
- Tightening Torque
- control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips no 1 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm
- Safe Separation Of Circuit
- 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
- Depth
- 126 mm
- Heat Dissipation
- 2-2 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.7-1.7 W control circuit with LUCM