Wago
2000-2202
1 / 2
- Part Number
- 2000-2202
- Tariff Code
- 85369010000
- UPC
- 4055143267731
- ETIM
- Group Code : EG000012
- Group Description : Terminal blocks
- Class Description : Feed-through terminal block
- Class Code : EC000897
- Version : 7
€1.87
net1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 40 pcs.In-StockUpdated at: 22-11-2024
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 2,990 Parts In-Stock from 12 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Available Offers (21)
Offer with manufacturer lead time
Ships in:On Request
Best price:
€0.68
Ratings Per Iec/En
- Ratings per
- IEC/EN 60947-7-1
- Nominal voltage (III/3)
- 500 V
- Rated impulse voltage (III/3)
- 6 kV
- Rated current
- 13.5 A
- Current at conductor cross-section (max.) mm²
- 16 A
- Legend (ratings)
- (III / 3) ≙ Overvoltage category III / Pollution degree 3
Environmental Requirements
- Processing temperature
- -35 … +85 °C
- Continuous operating temperature
- -60 … +105 °C
Physical Data
- Width
- 3.5 mm / 0.138 inches
- Height
- 69.7 mm / 2.744 inches
- Depth from upper-edge of DIN-rail
- 51.7 mm / 2.035 inches
Material Data
- Note (material data)
- <a href="https://www.wago.com/us/material-specifications" href="_blank">Information on material specifications can be found here</a>
- Color
- Gray
- Material group
- I
- Insulation material
- Polyamide (PA66)
- Flammability class per UL94
- V0
- Fire load
- 0.152 MJ
- Weight
- 7.320 g
Mechanical Data
- Potential marking
- N/L
- Mounting type
- DIN-35 rail
- Marking level
- Center/side marking
Connection 2
- Number of connection points 2
- 2
Specifications
- Product Group Code
- 0022
Commercial Data
- Packaging type
- Box
- Country of origin
- CN
- GTIN
- 4055143267731
- Customs tariff number
- 85369010000
Ex Information
- Reference hazardous areas
- See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
- Ratings per
- ATEX: PTB 11 ATEX 1041 U / IECEx: PTB 11.0093U (Ex eb IIC Gb)
- Rated voltage EN (Ex e II)
- 350 V
- Rated current (Ex e II)
- 13 A
- Rated current (Ex e II) with jumper
- 12 A
Ratings Per Csa
- Approvals per
- CSA 22.2 No 158
- Rated voltage CSA (Use Group B)
- 600 V
- Rated current CSA (Use Group B)
- 10 A
- Rated voltage CSA (Use Group C)
- 600 V
- Rated current CSA (Use Group C)
- 10 A
Power Loss
- Power loss, per pole (potential)
- 0.4338 W
- Rated current IN for specified power loss
- 13.5 A
- Resistance value for specified, current-dependent power loss
- 0.00238 Ω
Connection 1
- Connection technology
- Push-in CAGE CLAMP®
- Number of connection points
- 2
- Actuation type
- Operating tool
- Connectable conductor materials
- Copper
- Nominal cross-section
- 1 mm²
- Solid conductor
- 0.14 … 1.5 mm² / 24 … 16 AWG
- Solid conductor; push-in termination
- 0.5 … 1.5 mm² / 20 … 16 AWG
- Fine-stranded conductor
- 0.14 … 1.5 mm² / 24 … 16 AWG
- Fine-stranded conductor; with insulated ferrule
- 0.14 … 0.75 mm² / 24 … 18 AWG
- Fine-stranded conductor; with ferrule; push-in termination
- 0.5 … 0.75 mm² / 20 … 18 AWG
- Note (conductor cross-section)
- Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
- Strip length
- 9 … 11 mm / 0.35 … 0.43 inches
- Wiring direction
- Front-entry wiring
Ratings Per Ul 1059
- Approvals per
- UL 1059
- Rated voltage UL (Use Group B)
- 300 V
- Rated current UL (Use Group B)
- 15 A
- Rated voltage UL (Use Group C)
- 300 V
- Rated current UL (Use Group C)
- 15 A