Weidmuller

8444990000

1 / 3
thumbnail
thumbnail
thumbnail

Description

Signal converter/insulator, Tension-clamp connection
Part Number
8444990000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

General Data

Accuracy
± 0.2 % of final value
Configuration
none
Current consumption
< 32 mA @ IOUT = 20 mA
Current-carrying capacity of cross-connect.
≤ 2 A
Galvanic isolation
2-way isolator
Input/Output
4...20 mA/ 4...20 mA
Rail
TS 35
Step response time
≤ 30 ms (typ. 20 ms)
Temperature coefficient
≤ 250 ppm/K of final value
Voltage supply
24 V DC ± 20 %

Probability Of Failure

MTTF
520 Years

Approvals

Approvals
CE, CSA, CULUS, EAC
ROHS
Conform
UL File Number Search
E141197

Dimensions And Weights

Length
92.4 mm
Length (inches)
3.638 inch
Width
12.5 mm
Width (inches)
0.492 inch
Depth
112.4 mm
Depth (inches)
4.425 inch
Net weight
111 g

Connection Data

Type of connection
Tension-clamp connection
Stripping length, rated connection
7 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²

Tender Specification Sheets

Long specification
Standard signal isolating converter, 2-way isolation1-channel signal isolating converter in 12.5 mm width with output-sidepower supply for transmitting and isolating analogue 4...20 mADC current signals.The input circuit is powered by the current loop.Add-on housing for TS35 rail mountingDimensions: L/W/H 92.4/ 12.5/ 112.4 mmTension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20   Input                         4...20 mA / current-loop poweredOutput                                             4...20 mAApparent resistance at output            < 500 OhmTransmission error               < 0,2% v. E. Limit frequency 15 HzAuxiliary power                                     24 VDC +/- 20 %Ambient temperature range 0 °C...55 °CSecure isolation                   EN 50178, 2-way isolation up to 4 kV AC/DC Test voltage                               4 kV input against outputRated voltage                                         300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULusEX, CULus, CSAType                                                            WAZ4 CCC DC 4-20/4-20MA
Short specification
Standard signal isolating converter, 2-way isolation1-channel signal isolating converter in 12.5 mm width with output-side power supply for transmitting and isolating analogue 4...20 mA DC current signals. The input circuit is powered by the current loop.

Input

Number of inputs
1
Input current
4...20 mA
Voltage drop
Approx. 5.6 V at 20 mA

Output (Analogue)

Load resistance current
≤ 500 Ω
Output current
4...20 mA

Classifications

ETIM 6.0
EC002653
ETIM 7.0
EC002653
EClass 9.0
27-21-01-20
EClass 9.1
27-21-01-20
EClass 10.0
27-21-01-20
UNSPSC
31-12-10-07

Output

Number of outputs
1
Output current
4...20 mA
Cut-off frequency (-3 dB)
≥ 15 Hz (typ. 20 Hz)
Load impedance current
≤ 500 Ω

Product Information

Product information
This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Insulation Coordination

Clearance & creepage distances
≥ 3 mm
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
2-way isolator
Impulse withstand voltage
4 kV
Insulation voltage
1.2 kVeff / 5 s
Insulation voltage input or output/rail
4 kVeff / 1 min.
Insulation voltage input or output/supply
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III

Temperatures

Humidity
40 °C / 93 % rel. humidity, no condensation
Operating temperature, max.
55 °C
Operating temperature, min.
0 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-20 °C
Operating temperature
0 °C...55 °C
Storage temperature
-20 °C...85 °C

Ratings Iecex/Atex/Cul

Certificate no. (cULus)
E141197