- Prospective Line Isc
- 22 kA
- Electrical Connection
- VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 25-25 mm² / AWG 3
- Network Frequency
- 47.5...63 Hz
- Discrete Input Logic
- positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
- Type Of Cable
- without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
- Height
- 330 mm
- Acceleration And Deceleration Ramps
- automatic based on the load || linear adjustable separately from 0.01 to 3200 s
- Analogue Output Type
- FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
- Speed Drive Output Frequency
- 0.5-200 Hz
- Discrete Output Type
- configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
- Transmission Frame
- RTU
- Torque Accuracy
- +/- 15 %
- Asynchronous Motor Control Profile
- flux vector control without sensor, standard || voltage/frequency ratio, 2 points || voltage/frequency ratio, 5 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio - Energy Saving, quadratic U/f
- Maximum Switching Current
- 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
- Communication Service
- read device identification (43) || monitoring inhibitable || read holding registers (03) 2 words maximum || write multiple registers (16) 2 words maximum || write single register (06) || time out setting from 0.1 to 100 s
- Transient Overtorque
- 120-120 % of nominal motor torque +/- 10 % 60 s
- Insulation Resistance
- >= 1 mOhm 500 V DC for 1 minute
- Response Time
- FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
- Data Format
- 8 bits, 1 stop, odd even or no configurable parity
- Apparent Power
- 17.6 kVA 240 V
- Dielectric Strength
- 2830 V DC between earth and power terminals || 4230 V DC between control and power terminals
- Power Range
- 7-11 kW 200-240 V 3 phase
- Net Weight
- 11.55 kg
- Type Of Polarization
- no impedance
- Frequency Resolution
- display unit 0.1 Hz || analog input 0.024/50 Hz
- Accuracy
- +/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
- Switching Frequency
- 6...16 kHz adjustable || 12...16 kHz with derating factor
- Maximum Transient Current
- 50.8 A 60 s
- Connector Type
- 1 open style || 1 RJ45
- Analogue Input Number
- 2
- Motor Slip Compensation
- automatic whatever the load || adjustable || not available in voltage/frequency ratio motor control
- Motor Starter Type
- variable speed drive
- Discrete Output Number
- 2
- Minimum Switching Current
- 3 mA 24 V DC configurable relay logic
- Analogue Output Number
- 1
- Physical Interface
- 2-wire RS 485
- Power Dissipation In W
- 459 W
- Continuous Output Current
- 46.2 A 230 V
- Number Of Addresses
- 1-247
- Tightening Torque
- 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 4.5 N.m, 40 lb.in L1/R, L2/S, L3/T)
- Discrete Input Type
- F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
- Speed Range
- 1-10
- Isolation
- electrical between power and control
- Local Signalling
- for DC bus energized 1 LED (red)
- Linearity Error
- VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
- Specific Application
- HVAC
- Output Voltage
- <= power supply voltage
- Nominal Switching Frequency
- 12 kHz
- Width
- 245 mm
- Transmission Rate
- 9600 bps or 19200 bps
- Braking To Standstill
- by DC injection
- Air Flow
- 157 m3/h
- Depth
- 190 mm
- Protection Type
- overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit drive || against exceeding limit speed drive || line supply overvoltage and undervoltage drive || line supply undervoltage drive || against input phase loss drive || thermal protection motor || motor phase break motor || with PTC probes motor
- Supply
- internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
- Analogue Input Type
- VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
- Discrete And Process Manufacturing
- building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
- Sampling Duration
- 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
- Speed Accuracy
- +/- 10 % of nominal slip 0.2 Tn to Tn
- Option Card
- communication card LonWorks