standard auxiliary contact, ComPact NSXm, circuit breaker status OF/SD, 1 changeover contact type
LV426950
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
€22.33
1
Payment methods:
A total of 355 Parts In-Stock from 22 Distributors
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
€7.20

Additional Information

Part Number
LV426950
UNSPSC
39121522
Tariff Code
8536507000
Country of Origin
CN

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive
Compliant

Specifications

Range Compatibility
PowerPact PowerPact B || ComPact ComPact NSXm
Product Or Component Type
auxiliary contact
Signal Contacts Composition
1 NO/NC
Device Application
breaker status monitoring
Device Short Name
SD || OF

Complementary

Fault Type
overload || short-circuit
Auxiliary Connection Terminal
spring
[Ith] Conventional Free Air Thermal Current
5 A
Wire Stripping Length
8 mm for front connection
Mounting Mode
clip-on
Auxiliary Contacts Type
standard
[Ie] Rated Operational Current
AC-12: 5 A at 24 V AC 50/60 Hz || AC-12: 5 A at 48 V AC 50/60 Hz || AC-12: 5 A at 110...127 V AC 50/60 Hz || AC-12: 5 A at 220/240 V AC 50/60 Hz || AC-12: 5 A at 380/440 V AC 50/60 Hz || AC-12: 5 A at 660/690 V AC 50/60 Hz || AC-15: 5 A at 24 V AC 50/60 Hz || AC-15: 5 A at 48 V AC 50/60 Hz || AC-15: 4 A at 110...127 V AC 50/60 Hz || AC-15: 3 A at 220/240 V AC 50/60 Hz || AC-15: 2.5 A at 380/440 V AC 50/60 Hz || AC-15: 0.1 A at 660/690 V AC 50/60 Hz || DC-12: 5 A at 24 V DC 50/60 Hz || DC-12: 2.5 A at 48 V DC 50/60 Hz || DC-12: 0.6 A at 110 V DC 50/60 Hz || DC-12: 0.3 A at 250 V DC || DC-13: 2.5 A at 24 V DC || DC-13: 1.2 A at 48 V DC || DC-13: 0.35 A at 110 V DC || DC-13: 0.05 A at 250 V DC || DC-14: 1 A at 24 V DC || DC-14: 0.2 A at 48 V DC || DC-14: 0.05 A at 110 V DC || DC-14: 0.03 A at 250 V DC
Local Signalling
for open/close ON/OFF indication || for relay trip indicator trip indicator
Minimum Load
2 mA 17 V DC