pump control relay, Harmony Control Relays, 5A, 1CO, 208...480V AC
RM35BA10
RM35BA10
RM35BA10
RM35BA10
RM35BA10
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
A total of 58 Parts In-Stock from 19 Distributors
Offer with manufacturer lead time
Ships in:On Request
Best price:
€73.83

Additional Information

Part Number
RM35BA10
UNSPSC
39122331
Tariff Code
8536490080
Country of Origin
ID

Environment

Product Certifications
C-tick || CSA || GOST || UL || GL
Ambient Air Temperature For Operation
-20-50 °C
Standards
IEC 60255-6
Immunity To Microbreaks
500 ms
Electromagnetic Compatibility
emission standard for industrial environments IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments IEC 61000-6-3 || immunity for industrial environments NF EN/IEC 61000-6-2
Shock Resistance
15 gn 11 ms IEC 60255-21-1
Vibration Resistance
0.35 mm 5-57.6 Hz)IEC 60068-2-6/IEC 60255-21-1 || 1 gn 57.6-150 Hz)IEC 60068-2-6/IEC 60255-21-1
Ip Degree Of Protection
IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
Pollution Degree
3 IEC 60664-1
Ambient Air Temperature For Storage
-40-70 °C
Relative Humidity
95-95 % 55-55 °C IEC 60068-2-30
Dielectric Strength
2 kV AC 50 Hz shock wave 4 kV)

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1504008EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1504008EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Maximum Measuring Cycle
140 ms as true rms value
Hysteresis
5-5 % threshold
Insulation Resistance
> 500 MOhm 500 V DC between supply and relay output 60255-5 || > 500 MOhm 500 V DC between measurement and relay output 60664-1 || > 1 MOhm 500 V DC between supply and measurement 60255-5 || > 500 MOhm 500 V DC between supply and relay output 60664-1 || > 500 MOhm 500 V DC between measurement and relay output 60255-5 || > 1 MOhm 500 V DC between supply and measurement 60664-1
[Us] Rated Supply Voltage
208...480 V AC 3 phase || 230 V AC 1 phase
Operating Rate
<= 360 operations/hour full load
Status Led
1 LED Green power ON || 1 LED Yellow fault || 1 LED Yellow relay ON
Output Contacts
1 C/O
Reset Time
2000 ms
Marking
CE : EMC 89/336/EEC || CE : 73/23/EEC
Response Time
< 300 ms (in the event of a fault)
Input Current
11 A permanent at 25 °C E1-L2 terminals || 50 A non repetitive < 1 s at 25 °C E1-L2 terminals
Maximum Switching Voltage
250 V AC/DC
Connections - Terminals
screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Ui] Rated Insulation Voltage
400 V IEC 60664-1
Overvoltage Category
III IEC 60664-1
Supply Voltage Limits
183-528 V AC
Mounting Support
35 mm symmetrical DIN rail conforming to IEC 60715
Nominal Output Current
5 A
Mechanical Durability
30000000 cycles
Housing Material
self-extinguishing plastic
Resistance Across Terminals
0.01 Ohm E1-L2 terminals
Operating Position
any position
Control Circuit Voltage Limits
15 % + 10 % Un
Measurement Accuracy
+/- 10 % of the full scale value
Measurement Error
1 % by volt over the whole range || +/- 0.05 %/°C
Width
35 mm
Tightening Torque
0.6-1 N.m IEC 60947-1
Electrical Durability
100000 cycles
[Us] Rated Supply Voltage
208...480 V AC 3 phase || 230 V AC single phase
Run-Up Delay At Power-Up
0.5 s
Supply Frequency
50/60 Hz +/- 10 %
Repeat Accuracy
+/- 1 % input and measurement circuit || +/- 1 % time delay

Specifications

Minimum Switching Current
10 mA 5 V DC
Maximum Switching Current
5 A AC/DC
Range Of Product
Harmony Control Relays
Measurement Range
1...10 A AC
Switching Capacity In Va
1250 VA
Product Or Component Type
pump control relay
Utilisation Category
AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1
Relay Name
RM35BA
Relay Type
pump control relays
Product Specific Application
for 3-phase and single-phase pump
Time Delay Type
adjustable 1...60 s, +/- 10 % Ti on energisation || fixed 0.3 s reset on terminal Y2 || adjustable 0.1...10 s, +/- 10 % Tt on crossing the threshold
Relay Monitored Parameters
overcurrent and undercurrent control || phase sequence on 3-phase supply || phase failure on 3-phase supply
Maximum Power Consumption In Va
5 VA AC