Schneider Electric

SER8350A0B00

1 / 1
thumbnail

Description

Active Mature
Country of Origin
MX
Part Number
SER8350A0B00
Tariff Code
90321020
EAN
3606480771491
UNSPSC
39121601
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Housing Colour
silver
Ambient Air Temperature For Operation
0-50 °C
Height
120 mm
Calibration Certificate
1 Pt
Standards
EN/IEC 60730-1 || FCC part 15 Subpart B || ICES-003 || ETSI EN 300 328 || ETSI EN 301 489-1:v1.9.2 || FCC part 15 Subpart C || UL 60730-2-9 || ETSI EN 301 489-17:v2.2.1, 2012
Output Voltage
24 V AC relay output || 0...10 V DC analog output
Targeted Region
North America.
Product Or Component Type
room controller
Output Type
5 xrelay output || 4 xuniversal
Humidity Measurement Drift
Less Than 1 % Yearly
Product Name
SE8000 Series
Net Weight
340 g
Range
EcoStruxure Building Expert
Input Type
dry contact 2 || analog 5
Communication Port Protocol
BACnet MS/TP || Modbus RTU
Directives
2014/30/EU - electromagnetic compatibility || 2014/35/EU - low voltage directive || 2014/53/EU - radio equipment directive
Awg Gauge
AWG 24...AWG 18
Ambient Air Temperature For Storage
-30-50 °C
Output Current
1 A relay output
Input Voltage
0...10 V DC
Sensor Type
10 kOhm T2 NTC thermistor Temperature || space RH sensor Humidity || bulk polymer Humidity
Relative Humidity
0-95 %
Temperature Setting Range
12-37.5 °C cooling || 4.5-32 °C heating
Line Rated Current
4 A
Width
86 mm
Humidity Setting Range
30-95 %
Market Segment
Lodging/Hotel || small commercial || buildings || healthcare || non-critical buildings || office || residential || school
Temperature Resolution
0.1 °C
Depth
25 mm
Device Application
line voltage fan coil
Device Short Name
SER8300

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1410006
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: LEAD, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI1410006
Eu Rohs Directive
Compliant with Exemptions

Complementary

Surface Finish
Matte
Surface Treatment
untreated