1 / 3
thumbnail
thumbnail
thumbnail

Description

Active Mature
This Schneider Electric Zelio Logic SR3 compact smart relay / programmable controller uses a supply voltage of 12 volts direct current, has 26 inputs / outputs with screw-clamp terminals. It has an integrated clock and LCD display. This compact smart relays / programmable controller is ideal for management, remote control or monitoring of simple automation systems. It is suitable for both industrial and commercial applications. It has compact form-factor, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Simple ladder programming, adapted for non-specialists. Discovery package, coming with Zelio Soft programming software, the simplest way to learn and use this relay. Built-in EEPROM flash memory for data backup up to 10 years, easy-to-recover after a power shortage or incident. More I/O than SR2 model, for larger applications. Simple to select, install and program, Zelio Logic is suitable for all your applications. Flexible, it offers you the choice of 2 ranges, compact or modular, extendable and 2 programming languages (FBD or LADDER). Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards.
Country of Origin
FR
Part Number
SR3B261JD
Tariff Code
85371098
EAN
3389119203920
UNSPSC
39122331
€137.82
net
€153.14
Shipping from:
€25.00
1
Payment methods:
Best offer from:
ITTrusted Automa.Net Supplier
Availability:
41 pcs.
In-Stock
Updated at: 22-11-2024
Warranty:
12 months
Estimated Delivery:
27-29 November to United Kingdom
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Environment

Product Certifications
C-tick || UL || CSA || GL || GOST
Standards
IEC 60068-2-6 Fc || IEC 61000-4-12 || IEC 61000-4-3 || IEC 61000-4-6 level 3 || IEC 61000-4-5 || IEC 61000-4-11 || IEC 61000-4-2 level 3 || IEC 60068-2-27 Ea || IEC 61000-4-4 level 3
Disturbance Radiated/Conducted
class B EN 55022-11 group 1
Ambient Air Temperature For Operation
-20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
Immunity To Microbreaks
1 ms repeated 20 times
Environmental Characteristic
EMC directive IEC 61000-6-2 || EMC directive IEC 61000-6-3 || EMC directive IEC 61000-6-4 || EMC directive IEC 61131-2 zone B || low voltage directive IEC 61131-2
Ip Degree Of Protection
IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Pollution Degree
2 IEC 61131-2
Ambient Air Temperature For Storage
-40-70 °C
Relative Humidity
95-95 % without condensation or dripping water
Maximum Altitude Transport
3048 m
Operating Altitude
6561.68 ft (2000 m)

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP060406EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI0604006EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Contacts Type And Composition
NO relay output
Input Impedance
14 kOhm IB...IG used as analogue input circuit || 14 kOhm IB...IG used as discrete input circuit || 2.7 kOhm I1...IA and IH...IR discrete input circuit
Discrete Input Type
resistive
Number Of Outputs
10 relay
Analogue Input Range
0...12 V || 0...10 V
Conversion Error
+/- 5 % 25 °C analogue input circuit || +/- 6.2 % 55 °C analogue input circuit
Output Thermal Current
5 A for 2 outputs relay output || 8 A for 8 outputs relay output
Discrete Input Voltage
12 V DC
Number Or Control Scheme Lines
0-500 FBD || 0-240 ladder
Lsb Value
39 mV analogue input circuit
Backup Time
10 years 25 °C
Clock Drift
12 min/year 0-55 °C || 6 s/month 25-25 °C
Analogue Input Type
common mode
Discrete Input Current
4 mA
Current State 1 Guaranteed
>= 2 mA I1...IA and IH...IR discrete input circuit) || >= 0.5 mA IB...IG used as discrete input circuit)
Response Time
10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
Clock
with
Power Dissipation In W
3 W without extension || 5 W with extensions
Local Display
with
Net Weight
0.4 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Voltage State 0 Guaranteed
<= 3 V IB...IG used as discrete input circuit || <= 2.4 V I1...IA and IH...IR discrete input circuit
Output Voltage Limits
24...250 V AC relay output) || 5...30 V DC relay output)
Conversion Time
smart relay cycle time analogue input circuit
Electrical Durability
AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1
Connections - Terminals
screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid || screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid || screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end
Analogue Input Number
6
Voltage State 1 Guaranteed
>= 7 V IB...IG used as discrete input circuit || >= 5.6 V I1...IA and IH...IR discrete input circuit
Input Compatibility
3-wire proximity sensors PNP discrete input
Current State 0 Guaranteed
<= 0.2 mA IB...IG used as discrete input circuit) || <= 0.9 mA I1...IA and IH...IR discrete input circuit)
Supply Voltage Limits
10.4-14.4 V
Operating Distance
10 m between stations, with screened cable (sensor not isolated) analogue input circuit
Overvoltage Category
III IEC 60664-1
Mechanical Durability
10000000 cycles relay output
Maximum Supply Current
250 mA without extension) || 400 mA with extensions)
Tightening Torque
0.5 N.m
Switching Capacity In Ma
>= 10 mA 12 V relay output)
Analogue Input Resolution
8 bits at maximum voltage
Operating Rate In Hz
0.1 Hz at Ie)relay output || 10 Hz no load)relay output
Counting Frequency
1 kHz discrete input
Discrete Input Number
16 IEC 61131-2 Type 1
Cycle Time
6-90 ms
Reverse Polarity Protection
with
Maximum Permissible Voltage
14.4 V analogue input circuit
Repeat Accuracy
+/- 2 % 55 °C analogue input circuit
[Us] Rated Supply Voltage
12 V
Checks
program memory on each power up

Specifications

Range Of Product
Zelio Logic
Product Or Component Type
modular smart relay

CAD Models

traceparts
traceparts
Download