Schneider Electric
XB5AK123M5C0
1 / 5
Description
Active Mature
This illuminated selector switch provides a versatile and highly visible interface for controlling your machines. It is easily installed into standard 22mm cut-outs and connected to your control circuits with simple screw-clamp connections. It provides a clear help to set up your machines in various operating modes, even in darker rooms with clear visual feedback.- Country of Origin
- FR
- Part Number
- XB5AK123M5C0
- Tariff Code
- 85365080
- EAN
- 3606489758516
- UNSPSC
- 39122217
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Environment
- Product Certifications
- CSA || DNV || BV || LROS (Lloyds register of shipping) || GL || UL
- Ik Degree Of Protection
- IK04 IEC 50102
- Ambient Air Temperature For Operation
- -40-70 °C
- Resistance To Electromagnetic Fields
- 10 V/m IEC 61000-4-3
- Standards
- JIS C8201-5-1 || CSA C22.2 No 14 || IEC 60947-5-4 || UL 508 || IEC 60947-5-1 || IEC 60947-1 || JIS C8201-1
- Shock Resistance
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Vibration Resistance
- 5 gn 2-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP66 IEC 60529 || IP67 IEC 60529
- Ambient Air Temperature For Storage
- -40-70 °C
- Nema Degree Of Protection
- NEMA 13 || NEMA 4X
- Resistance To Electrostatic Discharge
- 6 kV on contact (on metal parts) IEC 61000-4-2 || 8 kV in free air (in insulating parts) IEC 61000-4-2
- Electrical Shock Protection Class
- class II IEC 60536
- Protective Treatment
- TH
- Resistance To Fast Transients
- 2 kV IEC 61000-4-4
- Electromagnetic Emission
- class B IEC 55011
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Important Information
- Important Message
- A change in appearance may be noted on the product but does not affect its use in terms of function and safety. This makes it compatible with our Universal LED blocks
Complementary
- Contacts Usage
- standard contacts
- Height
- 42 mm
- Terminals Description Iso N°1
- (13-14)NO || (11-12)NC
- Short-Circuit Protection
- 10 A cartridge fuse gG IEC 60947-5-1
- Contacts Material
- silver alloy (Ag/Ni)
- Light Source
- universal LED
- Positive Opening
- with IEC 60947-5-1 appendix K
- [Ith] Conventional Free Air Thermal Current
- 10 A IEC 60947-5-1
- Net Weight
- 0.516 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947-1
- Current Consumption
- 14 mA
- Device Presentation
- complete product
- Resistance To High Pressure Washer
- 7000000 Pa 55 °C 0.1 m
- Electrical Durability
- 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
- Service Life
- 100000 h at rated voltage and 25 °C
- Surge Withstand
- 1 kV IEC 61000-4-5
- [Ui] Rated Insulation Voltage
- 600 V 3)IEC 60947-1
- Signalling Type
- steady
- Operating Torque
- 0.14 N.m NO changing electrical state
- [Ie] Rated Operational Current
- 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
- Supply Voltage Limits
- 195-264 V AC
- Mechanical Durability
- 1000000 cycles
- Electrical Reliability
- λ < 10exp(-6) 5 V 1 mA in clean environment IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA in clean environment IEC 60947-5-4
- Width
- 30 mm
- Depth
- 70 mm
- Tightening Torque
- 0.8-1.2 N.m IEC 60947-1
- Shape Of Screw Head
- cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
Specifications
- Range Of Product
- Harmony XB5
- Mounting Diameter
- 22 mm
- Type Of Operator
- stay put
- Product Or Component Type
- illuminated selector switch
- Shape Of Signaling Unit Head
- round
- Head Type
- standard
- Connections - Terminals
- screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
- Contacts Type And Composition
- 1 NO + 1 NC
- Sale Per Indivisible Quantity
- 1
- Bezel Material
- plastic colour plated grey
- Contact Operation
- slow-break
- Operator Profile
- green standard handle
- Operator Position Information
- 2 positions 90°
- Device Short Name
- XB5
- [Us] Rated Supply Voltage
- 230...240 V AC 50/60 Hz
- Bulb Base
- integral LED
CAD Models
traceparts
Download