Schneider Electric
XCKM115H29
1 / 5
Description
Active Mature
This XCKM classic format limit switch has a thermoplastic roller lever and a Zamak body. This limit switch has a robust Zamak body, 3 cable entries, a modular design allowing easier maintenance and a classic format. It is IP66 and IK05 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508, BV standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.- Country of Origin
- ID
- Part Number
- XCKM115H29
- Tariff Code
- 85365080
- EAN
- 3389110973075
- UNSPSC
- 39122213
€46.27
net1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 3 pcs.In-StockUpdated at: 12-11-2024
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Specifications
- Movement Of Operating Head
- rotary
- Range Of Product
- Telemecanique Limit switches XC Standard
- Fixing Mode
- by the body
- Type Of Operator
- spring return roller lever thermoplastic
- Cable Entry
- 3 entries tapped for M20 x 1.5 cable gland 7-13 mm
- Product Or Component Type
- limit switch
- Material
- metal
- Head Type
- rotary head
- Type Of Approach
- lateral approach, 2 directions
- Series Name
- standard format
- Contacts Type And Composition
- 1 NC + 1 NO
- Body Type
- fixed
- Contact Operation
- snap action
- Body Material
- zamak
- Device Short Name
- XCKM
- Number Of Poles
- 2
Contractual warranty
- Warranty
- 18 months
Complementary
- Height
- 64-64 mm
- Terminals Description Iso N°1
- (21-22)NC || (13-14)NO
- Short-Circuit Protection
- 10 A cartridge fuse gG
- Minimum Actuation Speed
- 0.01 m/min
- Electrical Connection
- screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
- Number Of Steps
- 1
- Net Weight
- 0.28 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60664 || 6 kV IEC 60947-1
- Switch Actuation
- by 30° cam
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
- Electrical Durability
- 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
- Positive Opening
- with
- Contacts Insulation Form
- Zb
- Positive Opening Minimum Torque
- 0.25 N.m
- Mechanical Durability
- 15000000 cycles
- Maximum Actuation Speed
- 1.5 m/s
- Contact Code Designation
- A300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
- Width
- 64 mm
- Depth
- 30 mm
- Minimum Torque For Tripping
- 0.1 N.m
- [Ithe] Conventional Enclosed Thermal Current
- 10 A AC
- Maximum Resistance Across Terminals
- 25 MOhm IEC 60255-7 category 3
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110614EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CSA || UL || CCC
- Ik Degree Of Protection
- IK05 EN 50102
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- EN 60947-5-1 || EN 60204-1 || IEC 60947-5-1 || UL 508 || IEC 60204-1 || CSA C22.2 No 14
- Shock Resistance
- 50 gn 11 ms EN/IEC 60068-2-27
- Vibration Resistance
- 25 gn 10-500 Hz)EN/IEC 60068-2-6
- Ip Degree Of Protection
- IP66 conforming to EN/IEC 60529
- Ambient Air Temperature For Storage
- -40-70 °C
- Electrical Shock Protection Class
- class I IEC 61140 || class I NF C 20-030
- Protective Treatment
- TC