- Height
- 50-50 mm
- Short-Circuit Protection
- 4 A cartridge fuse gG
- Minimum Actuation Speed
- 0.01 m/min
- Electrical Connection
- male connector M12, 5 pins
- [Ithe] Conventional Enclosed Thermal Current
- 4 A
- Net Weight
- 0.1 kg
- [Uimp] Rated Impulse Withstand Voltage
- 0.8 kV IEC 60664 || 0.8 kV IEC 60947-1
- Switch Actuation
- on end
- [Ui] Rated Insulation Voltage
- 60 V 3)IEC 60947-5-1
- Electrical Durability
- 5000000 cycles, DC-13, 24 V, 3 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 2 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
- Positive Opening Minimum Force
- 42.5 N
- Positive Opening
- with
- Contacts Insulation Form
- Zb
- [Ie] Rated Operational Current
- 0.22 A 50 V, DC-13 EN/IEC 60947-5-1 appendix A || 3 A 50 V, AC-15 EN/IEC 60947-5-1 appendix A
- Mechanical Durability
- 10000000 cycles
- Maximum Actuation Speed
- 0.5 m/s
- Minimum Force For Tripping
- 8.5 N
- Width
- 30 mm
- Depth
- 16 mm
- Maximum Resistance Across Terminals
- 25 mOhm IEC 60255-7 category 3