This XCSB Key Operated Safety Switch for guard doors with unlocking by pushbutton has an adjustable turret head and a robust red coated Zamak body with a Pg 13.5 cable gland entry, allowing for flexible installation. It has 2 normally open and 1 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 3 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
FR
Part Number
XCSB501
Tariff Code
85365080
EAN
3389110184914
UNSPSC
39122213
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
A total of 2 Parts In-Stock from 2 Distributors
Delivery from:
DE
DE
GB
GB
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (1)

XCSB501 product image
Schneider Electric

XCSB501

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 21-10-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Specifications

Range Of Product
Telemecanique Safety switches XCS
Cable Entry
1 entry tapped Pg 13.5
Electrical Connection
terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Description
with locking of actuator, unlocking by push-button
Product Or Component Type
safety switch
Component Name
XCSB
Design
industrial
Material
metal
Head Type
key operated turret head
Contacts Type And Composition
1 NC + 2 NO
Contact Operation
slow-break, break before make
Local Signalling
without
Cable Outer Diameter
9-12 mm
Number Of Poles
3

Contractual warranty

Warranty
18 months

Complementary

Height
114-114 mm
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Minimum Actuation Speed
0.01 m/s
[Ithe] Conventional Enclosed Thermal Current
10 A
Head Material
zamak
Net Weight
0.475 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
Positive Opening
with NC contact
[Ie] Rated Operational Current
6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction
20 N
Mechanical Durability
600000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width
52 mm
Actuator Forcible Withdrawal Rtc
1500 N
Depth
44 mm
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || UL
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/IEC 60204-1 || UL 508 || EN 1088/ISO 14119 || CSA C22.2 No 14 || EN/ISO 12100 || EN/IEC 60947-5-1
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I EN/IEC 61140
Protective Treatment
TC