Schneider Electric
XCSLF353531M3
1 / 1
Description
Active Mature
This XCSLF Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated slim Zamak body with a 19-pin M23 connector, allowing for flexible installation. It has 2 normally open and 1 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 2 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 500 000. Its IP65 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.- Country of Origin
- ID
- Part Number
- XCSLF353531M3
- Tariff Code
- 85365080
- EAN
- 3606480465482
- UNSPSC
- 39122213
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 1 pc.In-StockUpdated at: 21-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Specifications
- [Us] Rated Supply Voltage
- 24 V - 15...10 %
- Range Of Product
- Telemecanique Safety switches XCS
- Electrical Connection
- male connector M23, 19 pins
- Locking Options Description
- with interlocking, locking by solenoid
- Solenoid Contacts Type And Composition
- 1 NC + 2 NO slow-break, break before make)
- Product Or Component Type
- safety switch
- Signalling Circuit Voltage
- 24 V
- Component Name
- XCSLF
- Material
- metal
- Design
- slim
- Head Type
- key operated turret head
- Contacts Type And Composition
- 1 NC + 2 NO
- Contact Operation
- slow-break, break before make
- Local Signalling
- for actuator withdrawn 1 LED (orange) || for actuator inserted and locked 1 LED (green)
- Electromagnet Interlocking
- locking on de-energisation and unlocking on energisation of solenoid
- Cable Outer Diameter
- 7-13 mm
- Number Of Poles
- 3
Contractual warranty
- Warranty
- 18 months
Complementary
- Minimum Switching Current
- 10 mA at 20 °C
- Height
- 225-225 mm
- Short-Circuit Protection
- 4 A cartridge fuse gG (gl) || 6 A fast blow
- Maximum Load Current
- <= 15 A
- Minimum Actuation Speed
- 0.01 m/s
- [Ithe] Conventional Enclosed Thermal Current
- 4 A
- Supply Voltage Type
- AC/DC
- Head Material
- zamak
- Signalling Circuit Type
- AC/DC
- Net Weight
- 1.1 kg
- [Uimp] Rated Impulse Withstand Voltage
- 0.8 kV EN/IEC 60947-5-1
- Maximum Operating Rate
- 10 cyc/mn for maximum durability
- [Ui] Rated Insulation Voltage
- 60 V 3)EN/IEC 60947-1 || 50 VUL 508 || 50 VCSA C22.2 No 14
- Positive Opening
- with NC contact
- Load Factor
- 1
- [Ie] Rated Operational Current
- 1.5 A 24 V, AC-15 EN/IEC 60947-5-1 || 0.22 A 24 V, DC-13 EN/IEC 60947-5-1
- Minimum Actuator Force For Extraction
- 20 N
- Mechanical Durability
- 1000000 cycles
- Maximum Actuation Speed
- 0.5 m/s
- Body Material
- zamak
- Safety Reliability Data
- B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear
- Width
- 44 mm
- Depth
- 51 mm
- Minimum Switching Voltage
- 17 V
- Maximum Actuator Forcible Withdrawal Rtc
- 3000 N
- Resistance To Mechanical Impact
- 9.6 J against the partition || 6.4 J without partition
- Supply Frequency
- 50/60 Hz
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CSA || UL || TÜV
- Ambient Air Temperature For Operation
- -25-60 °C
- Standards
- UL 508 || CSA C22.2 No 14 || EN/IEC 60204-1 || EN/IEC 60947-5-1 || EN 1088/ISO 14119 || EN/ISO 13849-1 || EN/IEC 62061
- Shock Resistance
- 10 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 5 gn 10-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP65 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 || IP65
- Ambient Air Temperature For Storage
- -40-70 °C
- Electrical Shock Protection Class
- class I EN/IEC 61140
- Protective Treatment
- TC