Schneider Electric

XCSLF3837512

1 / 1
thumbnail

Description

Active Mature
Country of Origin
ID
Part Number
XCSLF3837512
Tariff Code
85365080
EAN
3606489053444
UNSPSC
39122205
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

[Us] Rated Supply Voltage
24 V - 15...10 %
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
3 entries tapped M20 x 1.5
Electrical Connection
spring terminal 1 x 1.5 mm² flexible or solid cable || spring terminal 2 x 0.5 mm² flexible cables with 13 mm bared ends
Locking Options Description
with interlocking, locking by solenoid
Solenoid Contacts Type And Composition
2 NC + 1 NO slow-break, simultaneous)
Product Or Component Type
safety switch
Signalling Circuit Voltage
24 V
Component Name
XCSLF
Design
slim
Material
metal
Head Type
key operated turret head
Contacts Type And Composition
3 NC
Contact Operation
slow-break, simultaneous
Local Signalling
for actuator withdrawn 1 LED (orange) || for actuator inserted and locked 1 LED (green)
Electromagnet Interlocking
locking on energisation and unlocking on de-energisation of solenoid
Cable Outer Diameter
7-13 mm
Number Of Poles
3

Contractual warranty

Warranty
18 months

Complementary

Minimum Switching Current
10 mA at 20 °C
Height
205-205 mm
Maximum Load Current
<= 15 A
Short-Circuit Protection
4 A cartridge fuse gG (gl) || 6 A fast blow
Minimum Actuation Speed
0.01 m/s
[Ithe] Conventional Enclosed Thermal Current
4 A
Supply Voltage Type
AC/DC
Head Material
zamak
Signalling Circuit Type
AC/DC
Net Weight
1.1 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 250 V 3)EN/IEC 60947-1
Positive Opening
with NC contact
Load Factor
1
[Ie] Rated Operational Current
0.55 A 24 V, DC-13, R300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction
20 N
Mechanical Durability
1000000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
Safety Reliability Data
B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear
Width
44 mm
Depth
51 mm
Minimum Switching Voltage
17 V
Maximum Actuator Forcible Withdrawal Rtc
3000 N
Resistance To Mechanical Impact
9.6 J against the partition || 6.4 J without partition
Supply Frequency
50/60 Hz
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110916EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI110903EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
TÜV || UL || CSA
Ambient Air Temperature For Operation
-25-60 °C
Standards
EN/IEC 60204-1 || EN 1088/ISO 14119 || EN/IEC 62061 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508 || EN/ISO 13849-1
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 || IP67
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I EN/IEC 61140
Protective Treatment
TC