1 / 1
thumbnail

Description

Active Mature
This XCSM Miniature Safety Limit Switch has a metal end plunger, a Zamak body and head and a 5 meter pre-cabled. It has 1 normally open and 2 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 50 000 000. It has IK06 impact resistance and IP66 / IP67 / IP68 degree of protection, makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
ID
Part Number
XCSM3710L5
Tariff Code
85365080
EAN
3389110244182
UNSPSC
39122213
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

Contacts Type And Composition
1 NC + 1 NC + 1 NO
Type Of Approach
on end approach
Range Of Product
Telemecanique Safety switches XCS
Contact Operation
slow-break, break before make
Type Of Operator
metal end plunger
Product Or Component Type
safety limit switch
Protection Technology
plastic protective cover, secured by 5-lobe socket head safety screw
Component Name
XCSM
Material
metal
Design
miniature
Head Type
plunger head

Contractual warranty

Warranty
18 months

Complementary

Height
60-60 mm
[Ui] Rated Insulation Voltage
300 VUL 508 || 400 V 3)IEC 60947-5-1 || 300 VCSA C22.2 No 14
Short-Circuit Protection
6 A cartridge fuse gG (gl)
Positive Opening Minimum Force
42.5 N
Positive Opening
with NC contact
Minimum Actuation Speed
6 m/min
Repeat Accuracy
0.05 mm on the tripping points
Fixing Mode
by the body
Mechanical Durability
10000000 cycles
Maximum Actuation Speed
0.5 m/s
Cable Length
5 m
Body Material
zamak
Electrical Connection
pre-cabled
Minimum Force For Tripping
8.5 N
Cable Composition
7 x 0.5 mm²
Contact Code Designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN 60947-5-1 || B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN 60947-5-1 || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
Width
30 mm
Depth
16 mm
Head Material
zamak
Net Weight
0.165 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV IEC 60664 || 4 kV IEC 60947-1
Number Of Poles
3
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Circularity Profile
ENVEOLI110612EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110612EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CSA || UL
Ik Degree Of Protection
IK06 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN 1088 || EN/IEC 60204-1 || UL 508 || EN/IEC 60947-5-1 || CSA C22.2 No 14
Electrical Shock Protection Class
class I NF C 20-030 || class I EN/IEC 61140
Safety Reliability Data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Shock Resistance
25 gn 18 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529 || IP68 conforming to IEC 60529
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508