- Height
- 87-87 mm
- Maximum Operating Rate
- 20 cyc/mn for maximum durability
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
- Short-Circuit Protection
- 10 A cartridge fuse gG (gl)
- Insulation
- double insulated
- Positive Opening
- with NC contact
- Minimum Actuation Speed
- 0.05 m/s
- [Ie] Rated Operational Current
- 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1 || 1.5 A 120 V, AC-15, C300 EN/IEC 60947-5-1
- Minimum Actuator Force For Extraction
- 8 N
- Mechanical Durability
- 1000000 cycles
- Maximum Actuation Speed
- 1.5 m/s
- Cable Length
- 2 m
- Body Material
- PA (polyamide)
- [Ithe] Conventional Enclosed Thermal Current
- 2.5 A
- Safety Reliability Data
- B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
- Cable Composition
- 4 x 0.5 mm²
- Width
- 15 mm
- Actuator Forcible Withdrawal Rtc
- 8 N
- Depth
- 30 mm
- Head Material
- PA (polyamide)
- Net Weight
- 0.11 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-5-1
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508