Schneider Electric
XCSPA792
1 / 5
Description
Active Mature
This Preventa XCS Key Operated Safety Switch has an adjustable turret head and a plastic body. This key operated safety switch for guard doors, with adjustable turret head switch, has a robust red coated thermoplastic body. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. When wired as recommended in relevant standards, it conforms to category 4, performance level PL e, SIL 3 and complies withEN/ISO 13849-1, EN/IEC 61508. It simply ensures a "door-open machine stop" control on your machine, with maximal reliability. It secures the machine and system operation with a key, only available to authorized operators.- Country of Origin
- ID
- Part Number
- XCSPA792
- Tariff Code
- 85365080
- EAN
- 3389110720631
- UNSPSC
- 39122213
€25.00
netShipping from:
€40.00
1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 4 pcs.In-StockUpdated at: 21-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- 26-30 November to United Kingdom
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Specifications
- Range Of Product
- Telemecanique Safety switches XCS
- Cable Entry
- 1 entry tapped M16 x 1.5
- Electrical Connection
- terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
- Locking Options Description
- without locking of actuator
- Product Or Component Type
- safety switch
- Component Name
- XCSPA
- Design
- compact
- Material
- plastic
- Head Type
- key operated turret head
- Contacts Type And Composition
- 2 NC
- Contact Operation
- slow-break, simultaneous
- Cable Outer Diameter
- 7-10 mm
- Number Of Poles
- 2
Contractual warranty
- Warranty
- 18 months
Complementary
- Height
- 94-94 mm
- Short-Circuit Protection
- 10 A cartridge fuse gG (gl)
- Minimum Actuation Speed
- 0.01 m/s
- [Ithe] Conventional Enclosed Thermal Current
- 10 A
- Head Material
- PA (polyamide)
- Net Weight
- 0.11 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-5-1
- Maximum Operating Rate
- 10 cyc/mn for maximum durability
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
- Positive Opening Minimum Force
- 15 N
- Insulation
- double insulated
- Positive Opening
- with NC contact
- [Ie] Rated Operational Current
- 6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
- Mechanical Durability
- 1000000 cycles
- Maximum Actuation Speed
- 0.5 m/s
- Body Material
- PA (polyamide)
- Safety Reliability Data
- B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
- Width
- 30 mm
- Actuator Forcible Withdrawal Rtc
- 10 N
- Depth
- 30 mm
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110606EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI110603EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CSA || UL
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- EN/ISO 12100 || EN 1088/ISO 14119 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || UL 508 || EN/IEC 60204-1
- Shock Resistance
- 10 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 5 gn 10-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
- Ambient Air Temperature For Storage
- -40-70 °C
- Electrical Shock Protection Class
- class II EN/IEC 61140
- Protective Treatment
- TC