Schneider Electric

XMLD500D1S11

1 / 1
thumbnail
Country of Origin
CZ
Part Number
XMLD500D1S11
Tariff Code
90322000
EAN
3389110717181
UNSPSC
39122210
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

Contacts Type And Composition
2 C/O snap action, silver contacts || 2 C/O staggered, silver contacts
Pressure Sensor Type
electromechanical pressure sensor
Pressure Sensor Size
500 bar
Pressure Actuator
piston
Electrical Connection
screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Controlled Fluid
hydraulic oil 0-160 °C)
Awg Gauge
AWG 20...AWG 14
Range Of Product
OsiSense XM
Line Rated Current
3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 || 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 || 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1
Scale Type
fixed differential
Product Specific Application
dual stage
Pressure Switch Type Of Operation
detection of 2 single thresholds
Cable Entry
cable gland 9-13 mm
Electrical Circuit Type
control circuit
Enclosure Material
zinc alloy
Product Or Component Type
electromechanical pressure sensor
Maximum Permissible Accidental Pressure
1125 bar
Materials In Contact With Fluid
FPM, FKM || stainless steel || PTFE || brass || steel
Destruction Pressure
2250 bar
Local Display
without
Device Short Name
XMLD
Fluid Connection Type
G 1/4 (female) ISO 228

Contractual warranty

Warranty
18 months

Complementary

Repeat Accuracy
2 %
Height
113 mm
Maximum Operating Rate
60 cyc/mn
Terminal Block Type
8 terminals
[Ui] Rated Insulation Voltage
300 V UL 508 || 500 V EN/IEC 60947-1 || 300 V CSA C22.2 No 14
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Spread Between 2 Stages
16-244 bar
Natural Differential At High Setting
65 bar
Setting
external
Mechanical Durability
3000000 cycles
Width
46 mm
Depth
85 mm
Net Weight
0.75 kg
Natural Differential At Low Setting
21 bar
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals
25 mOhm IEC 255-7 category 3 || 25 mOhm NF C 93-050 method A
Maximum Permissible Pressure - Per Cycle
625 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110914EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CSA || EAC || UL
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
CSA C22.2 No 14 || CE || EN/IEC 60947-5-1 || UL 508
Protective Treatment
TC standard version
Electrical Shock Protection Class
class I IEC 1140 || class I IEC 536 || class I NF C 20-030
Operating Position
any position
Vibration Resistance
4 gn 30-500 Hz)IEC 60068-2-6
Shock Resistance
50 gn IEC 60068-2-27
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529