Schneider Electric

XMLP010BD71F

1 / 1
thumbnail

Description

Active Mature
This XMLP electronic pressure sensor has a a pressure rating of 10 bar, a M12 connector electrical connection and a G 1/4 a DIN 3852-e male fluid connection. This pressure transmitter is designed for accurate pressure control of air, fresh water, between 0°C and +135°C, refrigeration fluids, hydraulic oils and any fluid compatible with AISI 304 stainless steel, between -30°C and +135°C. It is fixed directly on tubage. It provides high corrosion resistance AISI 316L stainless steel and fluorocarbon resin pressure chamber for maximum longevity. 10 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits. It complies with EN/IEC 61326-2-3, RCM, cULus, EAC. Its very short body makes it ideal for fitting in tight tubage areas. This product replaces XMLP010BD71V.
Country of Origin
CH
Part Number
XMLP010BD71F
Tariff Code
90262020
EAN
3389119638784
UNSPSC
41111927
Payment methods:
Best offer from:
GBTrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-10-2024
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

Pressure Sensor Type
pressure transmitter
Analogue Output Function
0...10 V, 3-wire
Type Of Output Signal
analogue
Controlled Fluid
air -30-135 °C) || fresh water 0-135 °C) || hydraulic oil -30-135 °C) || gas -30-135 °C) || refrigeration fluid -30-135 °C)
Range Of Product
Telemecanique Pressure sensors XM
Electrical Connection
1 male connector M12 4 pins
Pressure Sensor Size
10-10 bar
Quantity Per Set
set of 1
Electrical Circuit Type
control circuit
Product Or Component Type
electronic pressure sensors
Type Of Packing
individual
[Us] Rated Supply Voltage
24 V DC SELV 12-33 V)
Local Display
without
Pressure Sensor Name
XMLP
Current Consumption
< 7 mA
Fluid Connection Type
G 1/4A (male) DIN 3852-E

Complementary

Accuracy
0.1 % of the measuring range
Diameter
26 mm
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Mechanical Durability
10000000 cycles
Drift Of The Zero Point
+/- 0.02 % of measuring range/°K
Operating Position
any position
Electromagnetic Compatibility
electrical fast transient/burst immunity test EN/IEC 61000-4-4 2 kV || electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 4 kV contact || 1.2/50 µs shock waves immunity test EN/IEC 61000-4-5 1 kV 42 Ohm || immunity to magnetic fields EN/IEC 61000-4-8 100 A/m 50 Hz || susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...3000 MHz || radiated RF fields EN/IEC 61000-4-6 10 V 0.01...80 MHz
Measurement Accuracy
+/- 0.5 % of the measuring range
Protection Type
load short-circuit || reverse polarity
Drift Of The Sensitivity
+/- 0.02 % of measuring range/°K
Maximum Permissible Accidental Pressure
30 bar
Materials In Contact With Fluid
fluorocarbon FPM || stainless steel AISI 316L
Length
38.1 mm
Destruction Pressure
60 bar
Net Weight
0.09 kg
Response Time On Output
<= 2 ms 10...90 % of full scale
Pressure Setting Range
0-10 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1511013EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
EAC || RCM || CE || cULus
Ambient Air Temperature For Operation
-30-85 °C
Ambient Air Temperature For Storage
-50-100 °C
Standards
EN/IEC 61326-2-3 || NSF ANSI 61
Shock Resistance
100 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
20 gn 15-2000 Hz) EN/IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529 || IP69K conforming to EN/IEC 60529