Schneider Electric
XMLR010G0T25
1 / 5
Description
Active Mature
This XMLR electronic pressure sensor has a 4 digit 7-segment display. This electronic pressure transmitter sensor with digital display is designed for accurate pressure measurement and display. It is fixed directly on tubage. It provides high corrosion resistance AISI 316L stainless steel and fluorocarbon resin pressure chamber for maximum longevity. 10 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits. It has a supply voltage of 24V DC and an analog ouput of 4mA to 20mA. It provides IP65/IP67 degree of protection. It is ideal in moulding and thermoforming presses, injection machines, pneumatic systems and assembly machinery, hydraulic systems of lifting and handling equipment, pumping and fresh water treatment. It complies with EN/IEC 61326-2-3 and UL 61010-1.- Country of Origin
- CH
- Part Number
- XMLR010G0T25
- Tariff Code
- 90262020
- EAN
- 3389119610490
- UNSPSC
- 41111927
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Pressure Sensor Type
- pressure transmitter
- Range Of Product
- Telemecanique Pressure sensors XM
- Pressure Switch Type Of Operation
- pressure transmitter
- Product Or Component Type
- electronic pressure sensors
- Fluid Connection Type
- G 1/4 (female) DIN 3852-Y
- Pressure Sensor Size
- 10 bar || 145 psi
- Controlled Fluid
- fresh water 0-80 °C) || air -20-80 °C) || hydraulic oil -20-80 °C) || refrigeration fluid -20-80 °C)
- Maximum Permissible Accidental Pressure
- 4 MPa || 580 psi || 40 bar
- [Us] Rated Supply Voltage
- 24 V DC SELV 17-33 V)
- Destruction Pressure
- 40 bar || 4 MPa || 580 psi
- Device Short Name
- XMLR
Complementary
- Display Accuracy
- <= 1 % of the measuring range
- Electrical Connection
- male connector M12, 4 pins
- Height
- 93 mm
- Accuracy
- <= 1 % of the measuring range
- Linearity Error
- <= 0.5 % of the measuring range
- Type Of Output Signal
- analogue
- Display Response Time Type
- fast 50 ms || normal 200 ms || slow 600 ms
- Repeat Accuracy
- <= 0.2 % of the measuring range
- Drift Of The Zero Point
- +/- 0.1 % of measuring range/°C
- Electromagnetic Compatibility
- susceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 || immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 || surge immunity test 1 kV EN/IEC 61000-4-5 || electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 || electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2
- Operating Position
- any position, but disposals can falsified the measurement in case of upside down mounting
- Materials In Contact With Fluid
- ceramic || fluorocarbon FKM (Viton) || 316L stainless steel
- Net Weight
- 0.19 kg
- Current Consumption
- <= 50 mA
- Maximum Delay First Up
- 300 ms
- Analogue Output Function
- 4...20 mA
- Scale Type
- fixed differential
- Mechanical Durability
- 10000000 cycles
- Housing Material
- polyacrylamide || 316L stainless steel
- Measurement Accuracy
- <= 0.6 % of the measuring range
- Protection Type
- overload protection || overvoltage protection || reverse polarity || short-circuit protection
- Drift Of The Sensitivity
- +/- 0.03 % of measuring range/°C
- Width
- 41 mm
- Display Type
- 4 digits 7 segments
- Front Material
- polyester
- [Uimp] Rated Impulse Withstand Voltage
- 0.5 kV DC
- Hysteresis
- <= 0.2 % of the measuring range
- Depth
- 42 mm
- Response Time On Output
- <= 10 ms analog output
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- EAC || cULus
- Ambient Air Temperature For Operation
- -20-80 °C
- Standards
- UL 61010-1 || EN/IEC 61326-2-3
- Shock Resistance
- 50 gn EN/IEC 60068-2-27
- Marking
- CE
- Vibration Resistance
- 20 gn 10-2000 Hz)EN/IEC 60068-2-6
- Ip Degree Of Protection
- IP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529
- Ambient Air Temperature For Storage
- -40-80 °C